The Hyundai i30 has 43 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2017, 2019.
Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2019. Supported for 2017.
Cycle fuel consumption HYUNDAI_CYCLE_FUEL_CONS
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 416 to 423 of the reply, 8 bits.
- Formula
(val × 8.478 ÷ 100)- Range
- 0 to 21.6189
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Request
01 9E - Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2019.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Request
01 5E - Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3212.75 L/h
- Unit
- L/h
Confirmed for 2017, 2023.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2019.
Fuel consumption HYUNDAI_FUEL_CONS
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 25647 ÷ 20000)- Range
- 0 to 326.9992 L
- Unit
- L
In testing for 2006 to 2017, 2019 to 2024.
Fuel consumption since last DPF regeneration HYUNDAI_FUEL_CONS_SINCE_DPF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 432 to 439 of the reply, 8 bits.
- Formula
(val × 1.2549)- Range
- 0 to 319 L
- Unit
- L
In testing for 2006 to 2017, 2019 to 2024.
Fuel cut HYUNDAI_FUEL_CUT
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2009, 2011, 2015, 2017, 2019 to 2022.
Fuel cut HYUNDAI_FUEL_CUT_7E0
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2006 to 2017, 2019 to 2024.
Fuel injection timing #1 HYUNDAI_FUEL_INJECTION_TIMING_1Confirmed
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2015 Hyundai i30.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0003 = 3 → (3 × 0.8192) = 2.4576 ms
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
Confirmed for 2009, 2011, 2015. In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2017, 2019 to 2022.
Fuel injection timing #2 HYUNDAI_FUEL_INJECTION_TIMING_2Confirmed
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2015 Hyundai i30.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0003 = 3 → (3 × 0.8192) = 2.4576 ms
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
Confirmed for 2009, 2011, 2015. In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2017, 2019 to 2022.
Fuel injection timing #3 HYUNDAI_FUEL_INJECTION_TIMING_3Confirmed
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2015 Hyundai i30.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0003 = 3 → (3 × 0.8192) = 2.4576 ms
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
Confirmed for 2009, 2011, 2015. In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2017, 2019 to 2022.
Fuel injection timing #4 HYUNDAI_FUEL_INJECTION_TIMING_4Confirmed
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2015 Hyundai i30.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0003 = 3 → (3 × 0.8192) = 2.4576 ms
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
Confirmed for 2009, 2011, 2015. In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2017, 2019 to 2022.
Fuel level HYUNDAI_FLI_VOL_THIRDGENConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 B0 02 - Service 22
DID B002 - Module
7C6 → 7CE - Every
1 s - Testing
Example reply from a 2023 Hyundai i30.
Bits 32 to 39 of the reply, 8 bits.
0x07 = 7 → (7 ÷ 2) = 3.5 L
- Formula
(val ÷ 2)- Range
- 0 to 127.5 L
- Unit
- L
Confirmed for 2017, 2019 to 2023. In testing for 2006 to 2008, 2010, 2012, 2014, 2016, 2024. Not supported for 2009, 2011, 2013, 2015.
Fuel level input HYUNDAI_CRUZ_FLI_INPUT
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553 L
- Unit
- L
In testing for 2006 to 2017, 2019 to 2024.
Fuel level, volume HYUNDAI_FLI_VOLConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 B0 02 - Service 22
DID B002 - Module
7C6 → 7CE - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 L
- Unit
- L
Confirmed for 2017, 2019 to 2023. In testing for 2006 to 2008, 2010, 2012, 2014, 2016, 2024. Not supported for 2009, 2011, 2013, 2015.
Fuel pressure HYUNDAI_FUEL_P
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel pressure HYUNDAI_FUEL_P_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 61 ÷ 10000)- Range
- 0 to 399.7635
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel pressure HYUNDAI_FUEL_P_V3
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 980392157 ÷ 100000)- Range
- 0 to 2500000
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel pressure deviation HYUNDAI_FUEL_P_DEV
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- -173889.9456 to 173884.6389
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel pressure set point HYUNDAI_FUEL_P_SET_POINT
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel pressure set point deviation HYUNDAI_FUEL_P_SET_POINT_DEV
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 53066 ÷ 10000)- Range
- -173886.6688 to 173881.3622
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel pressure target HYUNDAI_FUEL_P_TGT
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 61 ÷ 10000)- Range
- 0 to 399.7635
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel pressure, actual HYUNDAI_FUEL_P_ACT
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel pressure, set point HYUNDAI_FUEL_P_SET_POINT_7E0
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 2006 to 2017, 2019 to 2024.
Fuel Rail Pressure A FRP_ASAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2017, 2019.
Fuel Rail Pressure B FRP_BSAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2019. Supported for 2017.
Fuel Rail Temperature A FRT_ASAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019. Supported for 2017.
Fuel Rail Temperature B FRT_BSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019. Supported for 2017.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2019. Supported for 2009, 2011, 2015, 2020 to 2024.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2019. Supported for 2009, 2011, 2015, 2020 to 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019, 2021, 2023. Supported for 2020, 2022.
Fuel temperature HYUNDAI_FUEL_T
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 7843 ÷ 10000 − 50)- Range
- -50 to 149.9965 °C
- Unit
- °C
In testing for 2006 to 2017, 2019 to 2024.
Short term fuel % trim, bank 1 HYUNDAI_STFT_B1
- Request
21 15 - Service 21
PID 15 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0030517578 − 100)- Range
- 0 to 99.9969 %
- Unit
- %
In testing for 2006 to 2008, 2010, 2012 to 2016, 2023 to 2024. Not supported for 2009, 2011, 2017, 2019 to 2022.
Short term fuel % trim, bank 1 idle HYUNDAI_STFT_B1_IDLE
- Request
21 15 - Service 21
PID 15 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.046875)- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2008, 2010, 2012 to 2016, 2023 to 2024. Not supported for 2009, 2011, 2017, 2019 to 2022.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2019.
Fuel › Internal
Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2019.
Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2019.
Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2019.
Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2019.
Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2019.
Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017, 2019.