Hyundai i30

Fuel parameters

The Hyundai i30 has 43 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level HYUNDAI_FLI_VOL_THIRDGENConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing

Example reply from a 2023 Hyundai i30.

Bits 32 to 39 of the reply, 8 bits.

0x07 = 7 → (7 ÷ 2) = 3.5 L

Formula
(val ÷ 2)
Range
0 to 127.5 L
Unit
L

Confirmed for 2017, 2019 to 2023. In testing for 2006 to 2008, 2010, 2012, 2014, 2016, 2024. Not supported for 2009, 2011, 2013, 2015.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2017, 2019.

Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2019. Supported for 2017.

Cycle fuel consumption HYUNDAI_CYCLE_FUEL_CONS

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 423 of the reply, 8 bits.

Formula
(val × 8.478 ÷ 100)
Range
0 to 21.6189
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2019.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2017, 2023.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2019.

Fuel consumption HYUNDAI_FUEL_CONS

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 25647 ÷ 20000)
Range
0 to 326.9992 L
Unit
L

In testing for 2006 to 2017, 2019 to 2024.

Fuel consumption since last DPF regeneration HYUNDAI_FUEL_CONS_SINCE_DPF

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
(val × 1.2549)
Range
0 to 319 L
Unit
L

In testing for 2006 to 2017, 2019 to 2024.

Fuel cut HYUNDAI_FUEL_CUT

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2009, 2011, 2015, 2017, 2019 to 2022.

Fuel cut HYUNDAI_FUEL_CUT_7E0

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2017, 2019 to 2024.

Fuel injection timing #1 HYUNDAI_FUEL_INJECTION_TIMING_1Confirmed

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2015 Hyundai i30.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

0x0003 = 3 → (3 × 0.8192) = 2.4576 ms

Formula
(val × 0.8192)
Range
0 to 53686.272 ms
Unit
ms

Confirmed for 2009, 2011, 2015. In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2017, 2019 to 2022.

Fuel injection timing #2 HYUNDAI_FUEL_INJECTION_TIMING_2Confirmed

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2015 Hyundai i30.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

0x0003 = 3 → (3 × 0.8192) = 2.4576 ms

Formula
(val × 0.8192)
Range
0 to 53686.272 ms
Unit
ms

Confirmed for 2009, 2011, 2015. In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2017, 2019 to 2022.

Fuel injection timing #3 HYUNDAI_FUEL_INJECTION_TIMING_3Confirmed

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2015 Hyundai i30.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

0x0003 = 3 → (3 × 0.8192) = 2.4576 ms

Formula
(val × 0.8192)
Range
0 to 53686.272 ms
Unit
ms

Confirmed for 2009, 2011, 2015. In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2017, 2019 to 2022.

Fuel injection timing #4 HYUNDAI_FUEL_INJECTION_TIMING_4Confirmed

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2015 Hyundai i30.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

0x0003 = 3 → (3 × 0.8192) = 2.4576 ms

Formula
(val × 0.8192)
Range
0 to 53686.272 ms
Unit
ms

Confirmed for 2009, 2011, 2015. In testing for 2006 to 2008, 2010, 2012 to 2014, 2016, 2023 to 2024. Not supported for 2017, 2019 to 2022.

Fuel level HYUNDAI_FLI_VOL_THIRDGENConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing

Example reply from a 2023 Hyundai i30.

Bits 32 to 39 of the reply, 8 bits.

0x07 = 7 → (7 ÷ 2) = 3.5 L

Formula
(val ÷ 2)
Range
0 to 127.5 L
Unit
L

Confirmed for 2017, 2019 to 2023. In testing for 2006 to 2008, 2010, 2012, 2014, 2016, 2024. Not supported for 2009, 2011, 2013, 2015.

Fuel level input HYUNDAI_CRUZ_FLI_INPUT

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553 L
Unit
L

In testing for 2006 to 2017, 2019 to 2024.

Fuel level, volume HYUNDAI_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 L
Unit
L

Confirmed for 2017, 2019 to 2023. In testing for 2006 to 2008, 2010, 2012, 2014, 2016, 2024. Not supported for 2009, 2011, 2013, 2015.

Fuel pressure HYUNDAI_FUEL_P

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 53067 ÷ 10000)
Range
0 to 347774.5845
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel pressure HYUNDAI_FUEL_P_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 61 ÷ 10000)
Range
0 to 399.7635
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel pressure HYUNDAI_FUEL_P_V3

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 980392157 ÷ 100000)
Range
0 to 2500000
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel pressure deviation HYUNDAI_FUEL_P_DEV

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 53067 ÷ 10000)
Range
-173889.9456 to 173884.6389
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel pressure set point HYUNDAI_FUEL_P_SET_POINT

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 53067 ÷ 10000)
Range
0 to 347774.5845
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel pressure set point deviation HYUNDAI_FUEL_P_SET_POINT_DEV

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 53066 ÷ 10000)
Range
-173886.6688 to 173881.3622
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel pressure target HYUNDAI_FUEL_P_TGT

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 61 ÷ 10000)
Range
0 to 399.7635
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel pressure, actual HYUNDAI_FUEL_P_ACT

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 53067 ÷ 10000)
Range
0 to 347774.5845
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel pressure, set point HYUNDAI_FUEL_P_SET_POINT_7E0

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 53067 ÷ 10000)
Range
0 to 347774.5845
Unit
Raw value

In testing for 2006 to 2017, 2019 to 2024.

Fuel Rail Pressure A FRP_ASAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2017, 2019.

Fuel Rail Pressure B FRP_BSAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2019. Supported for 2017.

Fuel Rail Temperature A FRT_ASAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019. Supported for 2017.

Fuel Rail Temperature B FRT_BSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019. Supported for 2017.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2019. Supported for 2009, 2011, 2015, 2020 to 2024.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2019. Supported for 2009, 2011, 2015, 2020 to 2024.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019, 2021, 2023. Supported for 2020, 2022.

Fuel temperature HYUNDAI_FUEL_T

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
(val × 7843 ÷ 10000 − 50)
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2006 to 2017, 2019 to 2024.

Short term fuel % trim, bank 1 HYUNDAI_STFT_B1

  • Request21 15
  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0030517578 − 100)
Range
0 to 99.9969 %
Unit
%

In testing for 2006 to 2008, 2010, 2012 to 2016, 2023 to 2024. Not supported for 2009, 2011, 2017, 2019 to 2022.

Short term fuel % trim, bank 1 idle HYUNDAI_STFT_B1_IDLE

  • Request21 15
  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.046875)
Range
0 to 100 %
Unit
%

In testing for 2006 to 2008, 2010, 2012 to 2016, 2023 to 2024. Not supported for 2009, 2011, 2017, 2019 to 2022.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2019.

Fuel › Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017, 2019.

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017, 2019.

Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017, 2019.

Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017, 2019.

Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017, 2019.

Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017, 2019.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.