Honda Jazz

Connectable parameters

The Honda Jazz has 37 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Hybrid battery pack remaining charge BAT_SOCConfirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Request01 5B
  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Request01 5B
  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2025.

State of charge HONDA_SOC

Pelican can show this parameter as the state of charge.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2001 to 2023, 2025 to 2026. Not supported for 2024.

Fuel tank level

Fuel level HONDA_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 70 29
  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 L
Unit
L

Confirmed for 2021, 2024 to 2025. In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006.

Speed

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Request01 0D
  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2021, 2024 to 2025. Supported for 2006.

Odometer

Odometer HONDA_ODO_PCM

Pelican can show this parameter as the odometer.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2026.

Odometer HONDA_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2024. In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2025.

Odometer HONDA_ODO_V2

Pelican can show this parameter as the odometer.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA1D → 1D
  • Every30 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

Front left tire pressure

Front left tire pressure HONDA_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

Front right tire pressure

Front right tire pressure HONDA_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

Rear left tire pressure

Rear left tire pressure HONDA_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

Rear right tire pressure

Rear right tire pressure HONDA_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

CheckEngineLightOn

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

Pelican can show this parameter as the checkEngineLightOn.

  • Request01 01
  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2024. Supported for 2006, 2021, 2025.

Commanded lambda

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2021, 2024. Supported for 2025.

Distance since trouble codes were cleared

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Request01 31
  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2021, 2024 to 2025.

Engine coolant temperature

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021. Supported for 2006, 2025.

Engine coolant temperature sensor 1 HONDA_ECT_1

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2023, 2025 to 2026. Not supported for 2024.

Engine coolant temperature sensor 2 HONDA_ECT_2

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2023, 2025 to 2026. Not supported for 2024.

Engine coolant temperature sensor 3 HONDA_ECT_3

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2023, 2025 to 2026. Not supported for 2024.

Engine coolant temperature sensor 4 HONDA_ECT_4

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2023, 2025 to 2026. Not supported for 2024.

Engine load

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2024. Supported for 2006, 2025.

Front left tire temperature

Front left tire temperature HONDA_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 200 to 207 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

Front right tire temperature

Front right tire temperature HONDA_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 192 to 199 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

Fuel rate

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2021. Supported for 2025.

Mass air flow

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2024. Supported for 2021, 2025.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2024. Supported for 2021, 2025.

O2 lambda

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2021, 2024. Supported for 2025.

Rear left tire temperature

Rear left tire temperature HONDA_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 216 to 223 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

Rear right tire temperature

Rear right tire temperature HONDA_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2001 to 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2006, 2021, 2024 to 2025.

Short term fuel trim

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021, 2024. Supported for 2006, 2025.

Starter battery voltage

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2021, 2024. Supported for 2025.

High voltage battery voltage, line B HONDA_HVB_V_B

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

In testing for 2001 to 2023, 2025 to 2026. Not supported for 2024.

StoredDTCCount

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

Pelican can show this parameter as the storedDTCCount.

  • Request01 01
  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2024. Supported for 2006, 2021, 2025.

Throttle position

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Request01 11
  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2006, 2024 to 2025.

Traction battery current

High voltage battery total current HONDA_HVB_C_TOTAL

Pelican can show this parameter as the traction battery current.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-100 to 200 A
Unit
A

In testing for 2001 to 2023, 2025 to 2026. Not supported for 2024.

Traction battery voltage

High voltage battery voltage HONDA_HVB_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

In testing for 2001 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature

Transmission fluid temperature HONDA_ATF_T_V2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 30 83
  • Service 22DID 3083
  • ModuleDA1E → 1E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2001 to 2003, 2005, 2007 to 2020, 2022 to 2023, 2026. Not supported for 2004, 2006, 2021, 2024 to 2025.

Transmission fluid temperature, variant 4 HONDA_ATF_T_VAR_4

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 22 01
  • Service 22DID 2201
  • ModuleDA1E → 1E
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2001 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.