Honda HR-V

Engine parameters

The Honda HR-V has 91 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C clutch HRV_AC_CLU_PCMConfirmed

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C clutch HRV_AC_CLU_PCMConfirmed

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2024.

A/C clutch HRV_AC_CLUTCHConfirmed

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Active cylinders HRV_ACTIVE_CYL_PCM

  • Request22 26 15
  • Service 22DID 2615
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 1998 to 2006, 2013 to 2026.

Air conditioner clutch HRV_AC_CLU

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1998 to 2006, 2013 to 2026.

Air/gas ratio HRV_AIRGAS_RAT_PCMConfirmed

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2024.

Air/gas ratio HRV_AIRGAS_RATIOConfirmed

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Air/gas ratio HRV_AIRGAS_RATIO_V2

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 1998 to 2006, 2013 to 2023, 2025 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Supported for 2024. Not supported for 2020, 2022 to 2023, 2025.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Engine oil temperature, variant 3 HRV_EOT_VAR_3_PCM

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1998 to 2006, 2013 to 2026.

Engine oil temperature, variant 4 HRV_EOT_VAR_4_PCM

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1998 to 2006, 2013 to 2026.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Fuel/air commanded equivalence ratio HRV_FUELAIR_CARConfirmed

  • Request22 26 61
  • Service 22DID 2661
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 2229.081633)
Range
0 to 29.4
Unit
Number

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Fuel/air commanded equivalence ratio HRV_FUELAIR_CAR_PCM

  • Request22 26 61
  • Service 22DID 2661
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 2229.081633)
Range
0 to 29.4
Unit
Number

In testing for 1998 to 2006, 2013 to 2026.

Generator HRV_GEN

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1998 to 2006, 2013 to 2026.

Generator HRV_GENERATORConfirmed

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Generator HRV_GENERATOR_PCMConfirmed

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2024.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Knock control HRV_KNOCK_CONTROLConfirmed

ECU's determination of fuel quality.

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 2 ÷ 255)
Range
0 to 2
Unit
Raw value

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Maintenance, air cleaner HRV_MAINT_AIR_CLN

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Maintenance, cabin filter HRV_MAINT_CABIN_FLT

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Maintenance, engine coolant HRV_MAINT_COOL

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Maintenance, general inspection HRV_MAINT_INSP

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Maintenance, oil & filter HRV_MAINT_OIL_FLT

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Maintenance, rake fluid HRV_MAINT_BRK_FLD

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Maintenance, spark plugs & valves HRV_MAINT_SPARK

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Maintenance, transmission fluid HRV_MAINT_TRANS_FLD

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Misfire count #1 HRV_MIS_1Confirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Misfire count #1, variant 1 HRV_MIS_CNT_1_VAR_1_PCMConfirmed

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #1, variant 3 HRV_MIS_CNT_1_VAR_3_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #2 HRV_MIS_2Confirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Misfire count #2, variant 1 HRV_MIS_CNT_2_VAR_1_PCMConfirmed

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #2, variant 3 HRV_MIS_CNT_2_VAR_3_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #3 HRV_MIS_3Confirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Misfire count #3, variant 1 HRV_MIS_CNT_3_VAR_1_PCMConfirmed

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #3, variant 3 HRV_MIS_CNT_3_VAR_3_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #4 HRV_MIS_4Confirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Misfire count #4, variant 1 HRV_MIS_CNT_4_VAR_1_PCMConfirmed

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #4, variant 3 HRV_MIS_CNT_4_VAR_3_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #5, variant 1 HRV_MIS_CNT_5_VAR_1_PCMConfirmed

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #5, variant 3 HRV_MIS_CNT_5_VAR_3_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #6, variant 1 HRV_MIS_CNT_6_VAR_1_PCMConfirmed

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count #6, variant 3 HRV_MIS_CNT_6_VAR_3_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count 1 HRV_MIS_CNT_1

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2026.

Misfire count 1,, variant 1 HRV_MIS_CNT_1_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 1,, variant 2 HRV_MIS_CNT_1_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 1,, variant 3 HRV_MIS_CNT_1_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 2 HRV_MIS_CNT_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2026.

Misfire count 2,, variant 1 HRV_MIS_CNT_2_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 2,, variant 2 HRV_MIS_CNT_2_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 2,, variant 3 HRV_MIS_CNT_2_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 3 HRV_MIS_CNT_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2026.

Misfire count 3,, variant 1 HRV_MIS_CNT_3_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 3,, variant 2 HRV_MIS_CNT_3_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 3,, variant 3 HRV_MIS_CNT_3_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 4 HRV_MIS_CNT_4

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2026.

Misfire count 4,, variant 1 HRV_MIS_CNT_4_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 4,, variant 2 HRV_MIS_CNT_4_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 4,, variant 3 HRV_MIS_CNT_4_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 5,, variant 1 HRV_MIS_CNT_5_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 5,, variant 2 HRV_MIS_CNT_5_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 5,, variant 3 HRV_MIS_CNT_5_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 6,, variant 1 HRV_MIS_CNT_6_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 6,, variant 2 HRV_MIS_CNT_6_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Misfire count 6,, variant 3 HRV_MIS_CNT_6_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.

Variable timing control duty HRV_VTC_DUTYConfirmed

How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Not supported for 2020, 2022, 2025.

Variable valve timing duty HRV_VTC_DUTY_PCMConfirmed

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2024.

VTEC valve control HRV_VTEC_VALVE_CTRL

VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2023, 2025 to 2026

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1998 to 2006, 2013 to 2019, 2021, 2026. Supported for 2024. Not supported for 2020, 2022 to 2023, 2025.

Engine › Internal

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8196)
Range
0 to 7.999 V
Unit
V

Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.