The Honda HR-V has 8 ECU parameters.
● Confirmed◆ In testing○ Supported× Not supported
Knock control HRV_KNOCK_CTRL_PCMConfirmed
- Request
22 26 62 - Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Number
Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfire count, cylinder 1 HRV_MIS_1_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.
Misfire count, cylinder 2 HRV_MIS_2_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.
Misfire count, cylinder 3 HRV_MIS_3_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.
Misfire count, cylinder 4 HRV_MIS_4_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.
Misfire count, cylinder 5 HRV_MIS_5_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.
Misfire count, cylinder 6 HRV_MIS_6_PCMConfirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.
Variable valve control HRV_VTEC_CTRLConfirmed
- Request
22 26 12 - Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2021, 2025 to 2026. Not supported for 2022.