Honda HR-V

ECU parameters

The Honda HR-V has 8 ECU parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Knock control HRV_KNOCK_CTRL_PCMConfirmed

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 2 ÷ 255)
Range
0 to 2
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Knock control HRV_KNOCK_CTRL_PCMConfirmed

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 2 ÷ 255)
Range
0 to 2
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfire count, cylinder 1 HRV_MIS_1_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count, cylinder 2 HRV_MIS_2_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count, cylinder 3 HRV_MIS_3_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count, cylinder 4 HRV_MIS_4_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count, cylinder 5 HRV_MIS_5_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Misfire count, cylinder 6 HRV_MIS_6_PCMConfirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2019, 2021 to 2026

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 1998 to 2006, 2013 to 2019, 2021 to 2026.

Variable valve control HRV_VTEC_CTRLConfirmed

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1998 to 2006, 2013 to 2022, 2025 to 2026

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023 to 2024. In testing for 1998 to 2006, 2013 to 2021, 2025 to 2026. Not supported for 2022.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.