Honda Civic

Climate parameters

The Honda Civic has 3 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C pressure CIVIC_AC_PConfirmed

  • Request22 26 13
  • Service 22DID 2613
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1988 to 2011, 2014, 2016 to 2017, 2019 to 2026

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 1000 kPa
Unit
kPa

Confirmed for 2012 to 2013, 2015. In testing for 1988 to 1996, 1999 to 2004, 2006, 2014. Supported for 2018. Not supported for 1997 to 1998, 2005, 2007 to 2011, 2016 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C pressure CIVIC_AC_PConfirmed

  • Request22 26 13
  • Service 22DID 2613
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 1988 to 2011, 2014, 2016 to 2017, 2019 to 2026

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 1000 kPa
Unit
kPa

Confirmed for 2012 to 2013, 2015. In testing for 1988 to 1996, 1999 to 2004, 2006, 2014. Supported for 2018. Not supported for 1997 to 1998, 2005, 2007 to 2011, 2016 to 2017, 2019 to 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015. Supported for 2021, 2023, 2025.

Outside air temperature CIVIC_AATConfirmed

  • Request22 70 28
  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing for 1988 to 2015

Bits 136 to 143 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2016 to 2026. Not supported for 2015.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.