Battery parameters
The Honda Civic has 103 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2007 to 2026.
Distance traveled since last charge CIVIC_BAT_DISTConfirmed
- Request
22 22 40 - Service 22
DID 2240 - Module
DA0E → 0E - Every
1 s - Testing for 2014 to 2026
Bits 80 to 111 of the reply, 32 bits.
- Formula
val- Range
- 0 to 250000 km
- Unit
- km
Confirmed for 2012 to 2013. In testing for 2014.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 1 to 2 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
Confirmed for 2022 to 2023, 2025 to 2026.
High voltage battery cells, max state of charge CIVIC_CELL_MAX_SOCConfirmed
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 584 to 599 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery cells, max state of charge CIVIC_CELL_MIN_SOCConfirmed
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 600 to 615 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery module 1A temperature CIVIC_HVB_MOD_1A_TConfirmed
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery module 3A temperature CIVIC_HVB_MOD_3A_TConfirmed
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery total capacity CIVIC_HVB_CAPConfirmed
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery total current CIVIC_HVB_C_TOTALConfirmed
Pelican can show this parameter as the traction battery current.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -100 to 200 A
- Unit
- A
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
High voltage battery voltage CIVIC_HVB_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 400 V
- Unit
- V
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Request
01 5B - Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020, 2022 to 2023, 2025 to 2026. Supported for 2013, 2024.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2022 to 2023, 2025 to 2026.
State of charge CIVIC_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Battery › Cells
Individual cell voltage A1 CIVIC_CEL_V_A1Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 216 to 231 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A2 CIVIC_CEL_V_A2Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A3 CIVIC_CEL_V_A3Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 248 to 263 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A4 CIVIC_CEL_V_A4Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 264 to 279 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A5 CIVIC_CEL_V_A5Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 280 to 295 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A6 CIVIC_CEL_V_A6Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 296 to 311 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A7 CIVIC_CEL_V_A7Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 312 to 327 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A8 CIVIC_CEL_V_A8Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 328 to 343 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A9 CIVIC_CEL_V_A9Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 344 to 359 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A10 CIVIC_CEL_V_A10Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 360 to 375 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A11 CIVIC_CEL_V_A11Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 376 to 391 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A12 CIVIC_CEL_V_A12Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A13 CIVIC_CEL_V_A13Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A14 CIVIC_CEL_V_A14Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A15 CIVIC_CEL_V_A15Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A16 CIVIC_CEL_V_A16Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 456 to 471 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A17 CIVIC_CEL_V_A17Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 472 to 487 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A18 CIVIC_CEL_V_A18Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A19 CIVIC_CEL_V_A19Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 504 to 519 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A20 CIVIC_CEL_V_A20Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 520 to 535 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A21 CIVIC_CEL_V_A21Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 536 to 551 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A22 CIVIC_CEL_V_A22Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 552 to 567 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A23 CIVIC_CEL_V_A23Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 568 to 583 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A24 CIVIC_CEL_V_A24Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 584 to 599 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A25 CIVIC_CEL_V_A25Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 600 to 615 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A26 CIVIC_CEL_V_A26Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 616 to 631 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A27 CIVIC_CEL_V_A27Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 632 to 647 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A28 CIVIC_CEL_V_A28Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 648 to 663 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A29 CIVIC_CEL_V_A29Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 664 to 679 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A30 CIVIC_CEL_V_A30Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 680 to 695 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A31 CIVIC_CEL_V_A31Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 696 to 711 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A32 CIVIC_CEL_V_A32Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 712 to 727 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A33 CIVIC_CEL_V_A33Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 728 to 743 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A34 CIVIC_CEL_V_A34Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 744 to 759 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A35 CIVIC_CEL_V_A35Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 760 to 775 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A36 CIVIC_CEL_V_A36Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 776 to 791 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A37 CIVIC_CEL_V_A37Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 792 to 807 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A38 CIVIC_CEL_V_A38Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 808 to 823 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A39 CIVIC_CEL_V_A39Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 824 to 839 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A40 CIVIC_CEL_V_A40Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 840 to 855 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A41 CIVIC_CEL_V_A41Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 856 to 871 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A42 CIVIC_CEL_V_A42Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 872 to 887 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A43 CIVIC_CEL_V_A43Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 888 to 903 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A44 CIVIC_CEL_V_A44Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 904 to 919 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A45 CIVIC_CEL_V_A45Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 920 to 935 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A46 CIVIC_CEL_V_A46Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 936 to 951 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A47 CIVIC_CEL_V_A47Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 952 to 967 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A48 CIVIC_CEL_V_A48Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 968 to 983 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A49 CIVIC_CEL_V_A49Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 984 to 999 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A50 CIVIC_CEL_V_A50Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A51 CIVIC_CEL_V_A51Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A52 CIVIC_CEL_V_A52Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A53 CIVIC_CEL_V_A53Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A54 CIVIC_CEL_V_A54Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A55 CIVIC_CEL_V_A55Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A56 CIVIC_CEL_V_A56Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A57 CIVIC_CEL_V_A57Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A58 CIVIC_CEL_V_A58Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A59 CIVIC_CEL_V_A59Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A60 CIVIC_CEL_V_A60Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A61 CIVIC_CEL_V_A61Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A62 CIVIC_CEL_V_A62Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A63 CIVIC_CEL_V_A63Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A64 CIVIC_CEL_V_A64Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A65 CIVIC_CEL_V_A65Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A66 CIVIC_CEL_V_A66Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A67 CIVIC_CEL_V_A67Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A68 CIVIC_CEL_V_A68Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A69 CIVIC_CEL_V_A69Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A70 CIVIC_CEL_V_A70Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A71 CIVIC_CEL_V_A71Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A72 CIVIC_CEL_V_A72Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A73 CIVIC_CEL_V_A73Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A74 CIVIC_CEL_V_A74Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A75 CIVIC_CEL_V_A75Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A76 CIVIC_CEL_V_A76Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A77 CIVIC_CEL_V_A77Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A78 CIVIC_CEL_V_A78Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A79 CIVIC_CEL_V_A79Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A80 CIVIC_CEL_V_A80Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A81 CIVIC_CEL_V_A81Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A82 CIVIC_CEL_V_A82Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A83 CIVIC_CEL_V_A83Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Individual cell voltage A84 CIVIC_CEL_V_A84Confirmed
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2024
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2023, 2025 to 2026. Not supported for 2024.
Battery › Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2023, 2025 to 2026.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2023, 2025 to 2026.