Haval Jolion

Connectable parameters

The Haval Jolion has 9 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level, liters JOLION_FUEL_LEVEL_LITERSConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 01 06
  • Service 22DID 0106
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

0x0046 = 70 → (70 ÷ 10) = 7 L

Formula
(val ÷ 10)
Range
0 to 6553.5 L
Unit
L

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Fuel tank level

Fuel level JOLION_FUEL_LEVEL_INPUT

Pelican can show this parameter as the fuel tank level.

  • Request22 00 2F
  • Service 22DID 002F
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Fuel level, liters JOLION_FUEL_LEVEL_LITERSConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 01 06
  • Service 22DID 0106
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

0x0046 = 70 → (70 ÷ 10) = 7 L

Formula
(val ÷ 10)
Range
0 to 6553.5 L
Unit
L

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Fuel level, output JOLION_FUEL_LEVEL_OUTPUT

Pelican can show this parameter as the fuel tank level.

  • Request22 12 C5
  • Service 22DID 12C5
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Odometer

Odometer, engine JOLION_ODO_ENG

Pelican can show this parameter as the odometer.

  • Request22 12 1E
  • Service 22DID 121E
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission odometer JOLION_ODO_TRANS

Pelican can show this parameter as the odometer.

  • Request22 69 01
  • Service 22DID 6901
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle odometer JOLION_ODO

Pelican can show this parameter as the odometer.

  • Request22 00 A6
  • Service 22DID 00A6
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Engine oil temperature

Oil temperature JOLION_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 16 02
  • Service 22DID 1602
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature

Transmission fluid temperature JOLION_TFT

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D1 26
  • Service 22DID D126
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 60)
Range
-60 to 195 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission temperature, pan JOLION_TFT_PAN

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 6A 0A
  • Service 22DID 6A0A
  • Module7E1
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val − 55)
Range
-55 to 65480 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.