Climate parameters
The Haval Jolion has 2 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C pressure JOLION_AC_PRESSURE_HVAC
- Request
22 14 69 - Service 22
DID 1469 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1250 ÷ 10000 − 4096)- Range
- -4096 to 4095.875 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
A/C pressure, enhanced JOLION_AC_PRESSURE_HVAC2Confirmed
- Request
22 21 0C - Service 22
DID 210C - Module
7E0 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 2 ÷ 10) = 0 kPa
- Formula
(val × 2 ÷ 10)- Range
- -6553.6 to 6553.4 kPa
- Unit
- kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.