Haval Jolion HEV

Engine parameters

The Haval Jolion HEV has 36 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Oil temperature JOLIONHEV_OIL_TConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 01 07
  • Service 22DID 0107
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0B3A = 2874 → (2874 × 0.023437 − 273.15) = -205.792062 °C

Formula
(val × 0.023437 − 273.15)
Range
-273.15 to 1262.793795 °C
Unit
°C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Boost pressure JOLIONHEV_BOOST_PRESSURE_VALUE

  • Request22 01 6A
  • Service 22DID 016A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

In testing for 2021 to 2026.

Boost pressure, actual JOLIONHEV_BOOST_PRESSURE_ACTUALConfirmed

  • Request22 01 0F
  • Service 22DID 010F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x26E0 = 9952 → (9952 ÷ 128) = 77.75 kPa

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Boost pressure, target JOLIONHEV_BOOST_PRESSURE_TARGETConfirmed

  • Request22 01 12
  • Service 22DID 0112
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 128) = 0 kPa

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Injection pulse width JOLIONHEV_INJECTION_PULSE_WIDTH

  • Request22 01 6D
  • Service 22DID 016D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967.295 ms
Unit
ms

In testing for 2021 to 2026.

Knock counter JOLIONHEV_KNOCK_COUNTER

  • Request22 11 A0
  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Knock retard JOLIONHEV_KNOCK_RETARD

  • Request22 11 A6
  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 8.82 ÷ 100)
Range
0 to 22.491 °
Unit
°

In testing for 2021 to 2026.

Knock retard, cylinder 1 JOLIONHEV_KNOCK_RETARD_CYL_1Confirmed

  • Request22 01 70
  • Service 22DID 0170
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 3 ÷ 4) = 0 °

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard, cylinder 2 JOLIONHEV_KNOCK_RETARD_CYL_2Confirmed

  • Request22 01 71
  • Service 22DID 0171
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 3 ÷ 4) = 0 °

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard, cylinder 3 JOLIONHEV_KNOCK_RETARD_CYL_3Confirmed

  • Request22 01 72
  • Service 22DID 0172
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 3 ÷ 4) = 0 °

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard, cylinder 4 JOLIONHEV_KNOCK_RETARD_CYL_4Confirmed

  • Request22 01 73
  • Service 22DID 0173
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 3 ÷ 4) = 0 °

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor voltage, cylinder 1 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_1Confirmed

  • Request22 01 74
  • Service 22DID 0174
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor voltage, cylinder 2 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_2Confirmed

  • Request22 01 75
  • Service 22DID 0175
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor voltage, cylinder 3 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_3Confirmed

  • Request22 01 76
  • Service 22DID 0176
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor voltage, cylinder 4 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_4Confirmed

  • Request22 01 77
  • Service 22DID 0177
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfire current, total JOLIONHEV_MISFIRE_CURRENT_TOTAL

  • Request22 12 00
  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 256)
Range
0 to 65280
Unit
Number

In testing for 2021 to 2026.

Oil pressure JOLIONHEV_OIL_PRESSURE

  • Request22 FD 19
  • Service 22DID FD19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1023.984375 kPa
Unit
kPa

In testing for 2021 to 2026.

Oil temperature JOLIONHEV_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 16 02
  • Service 22DID 1602
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Oil temperature JOLIONHEV_OIL_TConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 01 07
  • Service 22DID 0107
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0B3A = 2874 → (2874 × 0.023437 − 273.15) = -205.792062 °C

Formula
(val × 0.023437 − 273.15)
Range
-273.15 to 1262.793795 °C
Unit
°C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Turbocharger inlet pressure JOLIONHEV_TURBOCHARGER_INLET_PRESSUREConfirmed

  • Request22 01 13
  • Service 22DID 0113
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x26F2 = 9970 → (9970 ÷ 128) = 77.890625 kPa

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Turbocharger inlet temperature JOLIONHEV_TURBOCHARGER_INLET_TConfirmed

  • Request22 01 14
  • Service 22DID 0114
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x3000 = 12288 → (12288 × 0.023437 − 273.15) = 14.843856 °C

Formula
(val × 0.023437 − 273.15)
Range
-273.15 to 1262.793795 °C
Unit
°C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Valve timing opening, intake, actual JOLIONHEV_INTAKE_VVT_ACTUALConfirmed

  • Request22 01 52
  • Service 22DID 0152
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x060B = 1547 → (1547 × 156 ÷ 10000) = 24.1332 °

Formula
(val × 156 ÷ 10000)
Range
-511.1808 to 511.1652 °
Unit
°

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Valve timing opening, intake, target JOLIONHEV_INTAKE_VVT_TARGETConfirmed

  • Request22 01 54
  • Service 22DID 0154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0611 = 1553 → (1553 × 78 ÷ 10000) = 12.1134 °

Formula
(val × 78 ÷ 10000)
Range
-255.5 to 255.5 °
Unit
°

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Variable clutch pressure control, min oil temperature JOLIONHEV_OT_VCPC_MIN

  • Request22 16 03
  • Service 22DID 1603
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Engine › Misfires

Misfire current cylinder 1 JOLIONHEV_MISFIRE_CURRENT_CYL_1

  • Request22 12 06
  • Service 22DID 1206
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Misfire current cylinder 2 JOLIONHEV_MISFIRE_CURRENT_CYL_2

  • Request22 12 05
  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Misfire current cylinder 3 JOLIONHEV_MISFIRE_CURRENT_CYL_3

  • Request22 12 07
  • Service 22DID 1207
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Misfire current cylinder 4 JOLIONHEV_MISFIRE_CURRENT_CYL_4

  • Request22 12 08
  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Misfire history cylinder 1 JOLIONHEV_MISFIRE_HISTORY_CYL_1

  • Request22 12 01
  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfire history cylinder 2 JOLIONHEV_MISFIRE_HISTORY_CYL_2

  • Request22 12 02
  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfire history cylinder 3 JOLIONHEV_MISFIRE_HISTORY_CYL_3

  • Request22 12 03
  • Service 22DID 1203
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfire history cylinder 4 JOLIONHEV_MISFIRE_HISTORY_CYL_4

  • Request22 12 04
  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 1 JOLIONHEV_MISFIRES_CYL_1Confirmed

  • Request22 01 80
  • Service 22DID 0180
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires, cylinder 2 JOLIONHEV_MISFIRES_CYL_2Confirmed

  • Request22 01 83
  • Service 22DID 0183
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires, cylinder 3 JOLIONHEV_MISFIRES_CYL_3Confirmed

  • Request22 01 81
  • Service 22DID 0181
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires, cylinder 4 JOLIONHEV_MISFIRES_CYL_4Confirmed

  • Request22 01 82
  • Service 22DID 0182
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires, total count JOLIONHEV_MISFIRES_TOTALConfirmed

  • Request22 01 7F
  • Service 22DID 017F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.