Engine parameters
The Haval Jolion HEV has 36 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Boost pressure JOLIONHEV_BOOST_PRESSURE_VALUE
- Request
22 01 6A - Service 22
DID 016A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Boost pressure, actual JOLIONHEV_BOOST_PRESSURE_ACTUALConfirmed
- Request
22 01 0F - Service 22
DID 010F - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x26E0 = 9952 → (9952 ÷ 128) = 77.75 kPa
- Formula
(val ÷ 128)- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Boost pressure, target JOLIONHEV_BOOST_PRESSURE_TARGETConfirmed
- Request
22 01 12 - Service 22
DID 0112 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 128) = 0 kPa
- Formula
(val ÷ 128)- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Injection pulse width JOLIONHEV_INJECTION_PULSE_WIDTH
- Request
22 01 6D - Service 22
DID 016D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967.295 ms
- Unit
- ms
In testing for 2021 to 2026.
Knock counter JOLIONHEV_KNOCK_COUNTER
- Request
22 11 A0 - Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Knock retard JOLIONHEV_KNOCK_RETARD
- Request
22 11 A6 - Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 8.82 ÷ 100)- Range
- 0 to 22.491 °
- Unit
- °
In testing for 2021 to 2026.
Knock retard, cylinder 1 JOLIONHEV_KNOCK_RETARD_CYL_1Confirmed
- Request
22 01 70 - Service 22
DID 0170 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 × 3 ÷ 4) = 0 °
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard, cylinder 2 JOLIONHEV_KNOCK_RETARD_CYL_2Confirmed
- Request
22 01 71 - Service 22
DID 0171 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 × 3 ÷ 4) = 0 °
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard, cylinder 3 JOLIONHEV_KNOCK_RETARD_CYL_3Confirmed
- Request
22 01 72 - Service 22
DID 0172 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 × 3 ÷ 4) = 0 °
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard, cylinder 4 JOLIONHEV_KNOCK_RETARD_CYL_4Confirmed
- Request
22 01 73 - Service 22
DID 0173 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 × 3 ÷ 4) = 0 °
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor voltage, cylinder 1 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_1Confirmed
- Request
22 01 74 - Service 22
DID 0174 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor voltage, cylinder 2 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_2Confirmed
- Request
22 01 75 - Service 22
DID 0175 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor voltage, cylinder 3 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_3Confirmed
- Request
22 01 76 - Service 22
DID 0176 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor voltage, cylinder 4 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_4Confirmed
- Request
22 01 77 - Service 22
DID 0177 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfire current, total JOLIONHEV_MISFIRE_CURRENT_TOTAL
- Request
22 12 00 - Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 256)- Range
- 0 to 65280
- Unit
- Number
In testing for 2021 to 2026.
Oil pressure JOLIONHEV_OIL_PRESSURE
- Request
22 FD 19 - Service 22
DID FD19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1023.984375 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Oil temperature JOLIONHEV_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 16 02 - Service 22
DID 1602 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Oil temperature JOLIONHEV_OIL_TConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 01 07 - Service 22
DID 0107 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0B3A = 2874 → (2874 × 0.023437 − 273.15) = -205.792062 °C
- Formula
(val × 0.023437 − 273.15)- Range
- -273.15 to 1262.793795 °C
- Unit
- °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Turbocharger inlet pressure JOLIONHEV_TURBOCHARGER_INLET_PRESSUREConfirmed
- Request
22 01 13 - Service 22
DID 0113 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x26F2 = 9970 → (9970 ÷ 128) = 77.890625 kPa
- Formula
(val ÷ 128)- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Turbocharger inlet temperature JOLIONHEV_TURBOCHARGER_INLET_TConfirmed
- Request
22 01 14 - Service 22
DID 0114 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x3000 = 12288 → (12288 × 0.023437 − 273.15) = 14.843856 °C
- Formula
(val × 0.023437 − 273.15)- Range
- -273.15 to 1262.793795 °C
- Unit
- °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Valve timing opening, intake, actual JOLIONHEV_INTAKE_VVT_ACTUALConfirmed
- Request
22 01 52 - Service 22
DID 0152 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x060B = 1547 → (1547 × 156 ÷ 10000) = 24.1332 °
- Formula
(val × 156 ÷ 10000)- Range
- -511.1808 to 511.1652 °
- Unit
- °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Valve timing opening, intake, target JOLIONHEV_INTAKE_VVT_TARGETConfirmed
- Request
22 01 54 - Service 22
DID 0154 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0611 = 1553 → (1553 × 78 ÷ 10000) = 12.1134 °
- Formula
(val × 78 ÷ 10000)- Range
- -255.5 to 255.5 °
- Unit
- °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Variable clutch pressure control, min oil temperature JOLIONHEV_OT_VCPC_MIN
- Request
22 16 03 - Service 22
DID 1603 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine › Misfires
Misfire current cylinder 1 JOLIONHEV_MISFIRE_CURRENT_CYL_1
- Request
22 12 06 - Service 22
DID 1206 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire current cylinder 2 JOLIONHEV_MISFIRE_CURRENT_CYL_2
- Request
22 12 05 - Service 22
DID 1205 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire current cylinder 3 JOLIONHEV_MISFIRE_CURRENT_CYL_3
- Request
22 12 07 - Service 22
DID 1207 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire current cylinder 4 JOLIONHEV_MISFIRE_CURRENT_CYL_4
- Request
22 12 08 - Service 22
DID 1208 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire history cylinder 1 JOLIONHEV_MISFIRE_HISTORY_CYL_1
- Request
22 12 01 - Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire history cylinder 2 JOLIONHEV_MISFIRE_HISTORY_CYL_2
- Request
22 12 02 - Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire history cylinder 3 JOLIONHEV_MISFIRE_HISTORY_CYL_3
- Request
22 12 03 - Service 22
DID 1203 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire history cylinder 4 JOLIONHEV_MISFIRE_HISTORY_CYL_4
- Request
22 12 04 - Service 22
DID 1204 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfires, cylinder 1 JOLIONHEV_MISFIRES_CYL_1Confirmed
- Request
22 01 80 - Service 22
DID 0180 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires, cylinder 2 JOLIONHEV_MISFIRES_CYL_2Confirmed
- Request
22 01 83 - Service 22
DID 0183 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires, cylinder 3 JOLIONHEV_MISFIRES_CYL_3Confirmed
- Request
22 01 81 - Service 22
DID 0181 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires, cylinder 4 JOLIONHEV_MISFIRES_CYL_4Confirmed
- Request
22 01 82 - Service 22
DID 0182 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires, total count JOLIONHEV_MISFIRES_TOTALConfirmed
- Request
22 01 7F - Service 22
DID 017F - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.