Connectable parameters
The Haval Jolion HEV has 14 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
State of charge
State of charge JOLIONHEV_BMS_BATT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 E0 F4 - Service 22
DID E0F4 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x01E9 = 489 → (489 ÷ 10) = 48.9 %
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
State of health
State of health JOLIONHEV_BMS_PACK_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
22 E0 F5 - Service 22
DID E0F5 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
0x62 = 98 → 98 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Fuel tank level
Fuel level JOLIONHEV_FUEL_LEVEL_INPUT
Pelican can show this parameter as the fuel tank level.
- Request
22 00 2F - Service 22
DID 002F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Fuel level, liters JOLIONHEV_FUEL_LEVEL_LITERS
Pelican can show this parameter as the fuel tank level.
- Request
22 01 06 - Service 22
DID 0106 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2021 to 2026.
Fuel level, output JOLIONHEV_FUEL_LEVEL_OUTPUT
Pelican can show this parameter as the fuel tank level.
- Request
22 12 C5 - Service 22
DID 12C5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Odometer
Odometer, engine JOLIONHEV_ODO_ENG
Pelican can show this parameter as the odometer.
- Request
22 12 1E - Service 22
DID 121E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 km
- Unit
- km
In testing for 2021 to 2026.
Transmission odometer JOLIONHEV_ODO_TRANS
Pelican can show this parameter as the odometer.
- Request
22 69 01 - Service 22
DID 6901 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 km
- Unit
- km
In testing for 2021 to 2026.
Vehicle odometer JOLIONHEV_ODO
Pelican can show this parameter as the odometer.
- Request
22 00 A6 - Service 22
DID 00A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2021 to 2026.
Engine oil temperature
Oil temperature JOLIONHEV_OIL_TConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 01 07 - Service 22
DID 0107 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0B3A = 2874 → (2874 × 0.023437 − 273.15) = -205.792062 °C
- Formula
(val × 0.023437 − 273.15)- Range
- -273.15 to 1262.793795 °C
- Unit
- °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Oil temperature JOLIONHEV_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 16 02 - Service 22
DID 1602 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Traction battery capacity
State of energy JOLIONHEV_BMS_PACK_SOEConfirmed
Pelican can show this parameter as the traction battery capacity.
- Request
22 E0 F6 - Service 22
DID E0F6 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0005 = 5 → (5 ÷ 10) = 0.5 kWh
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 kWh
- Unit
- kWh
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Traction battery voltage
HV battery voltage JOLIONHEV_BMS_PACK_VOLTAGEConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 E0 06 - Service 22
DID E006 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0D1F = 3359 → (3359 ÷ 10) = 335.9 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Transmission fluid temperature
Transmission fluid temperature JOLIONHEV_TFT
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 D1 26 - Service 22
DID D126 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 60)- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2021 to 2026.
Transmission temperature, pan JOLIONHEV_TFT_PAN
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 6A 0A - Service 22
DID 6A0A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val − 55)- Range
- -55 to 65480 °C
- Unit
- °C
In testing for 2021 to 2026.