Ford Territory

Climate parameters

The Ford Territory has 9 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor current FORD_AC_COMP_A

  • Request22 99 AB
  • Service 22DID 99AB
  • Module7C7 → 7CF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 A
Unit
A

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2024 to 2026. Not supported for 2012, 2014, 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor current FORD_AC_COMP_A

  • Request22 99 AB
  • Service 22DID 99AB
  • Module7C7 → 7CF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 A
Unit
A

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2024 to 2026. Not supported for 2012, 2014, 2023.

A/C compressor pressure sensor voltage FORD_AC_P_SENS_V

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2024 to 2026. Not supported for 2012, 2014, 2023.

A/C compressor, state FORD_AC_STATE

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2024 to 2026. Not supported for 2012, 2014, 2023.

A/C refrigerant pressure FORD_PCM_A_C_REFRIG_P

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2024 to 2026. Not supported for 2012, 2014, 2023.

Ambient temperature, alternate FORD_AAT_ALT

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2024 to 2026. Not supported for 2012, 2014, 2023.

Coolant heater operation mode FORD_COOLANT_HTR_OP_MODE

  • Request22 48 DF
  • Service 22DID 48DF
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2DEGRADEDDegraded
3SHUTDOWNShutdown
4SHORTShort
5NO_RESPONSENo response
6UNKNOWNUnknown
7STOPStop

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2024 to 2026. Not supported for 2012, 2014, 2023.

Coolant heater power FORD_COOLANT_HTR_PWR

  • Request22 48 DE
  • Service 22DID 48DE
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 kW
Unit
kW

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2024 to 2026. Not supported for 2012, 2014, 2023.

Exterior temperature FORD_AAT

  • Request22 DD 05
  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2025 to 2026. Not supported for 2012, 2014, 2023 to 2024.

Interior temperature FORD_IAT

  • Request22 DD 04
  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2004 to 2011, 2013, 2015 to 2016, 2018 to 2022, 2025 to 2026. Not supported for 2012, 2014, 2023 to 2024.