Fuel parameters
The Ford Ranger has 32 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Air/fuel ratio RANGER_AIR_FUEL_RATConfirmed
- Request
22 F4 34 - Service 22
DID F434 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 0.000446787) = 0
- Formula
(val × 0.000446787)- Range
- 0 to 29.2801
- Unit
- Number
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2024.
Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2024.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Request
01 9E - Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2024.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Request
01 5E - Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3212.75 L/h
- Unit
- L/h
Confirmed for 2018, 2020 to 2022, 2024 to 2026. Supported for 2019, 2023.
Engine fuel rate RANGER_ENG_FUEL_RATEConfirmed
- Request
22 F4 5E - Service 22
DID F45E - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 20) = 0 L
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 L
- Unit
- L
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024.
Fuel correction, cylinder 1 RANGER_FUEL_CORR_CYL_1
- Request
22 09 8A - Service 22
DID 098A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel correction, cylinder 2 RANGER_FUEL_CORR_CYL_2
- Request
22 09 8B - Service 22
DID 098B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel correction, cylinder 3 RANGER_FUEL_CORR_CYL_3
- Request
22 09 8C - Service 22
DID 098C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel correction, cylinder 4 RANGER_FUEL_CORR_CYL_4
- Request
22 09 8D - Service 22
DID 098D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel correction, cylinder 5 RANGER_FUEL_CORR_CYL_5
- Request
22 11 D3 - Service 22
DID 11D3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel correction, cylinder 6 RANGER_FUEL_CORR_CYL_6
- Request
22 04 8F - Service 22
DID 048F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel injection impulse width RANGER_FUEL_INJ_IMPULSE
- Request
22 16 8B - Service 22
DID 168B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 125000)- Range
- 0 to 0.1 s
- Unit
- s
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel level RANGER_FLI_7E0
Pelican can show this parameter as the fuel tank level.
- Request
22 16 C1 - Service 22
DID 16C1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030518509)- Range
- 0 to 200 %
- Unit
- %
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel pump duty cycle RANGER_FUEL_PMP_DUTY
- Request
22 16 72 - Service 22
DID 1672 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25 ÷ 32)- Range
- 0 to 199.2187 %
- Unit
- %
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel Rail Pressure A FRP_ASAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2024.
Fuel Rail Pressure B FRP_BSAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2024.
Fuel Rail Temperature A FRT_ASAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024.
Fuel Rail Temperature B FRT_BSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013 to 2014, 2018, 2020 to 2021, 2023 to 2026. Supported for 2009, 2011 to 2012, 2019, 2022.
Fuel tank level RANGER_FLIConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 61 85 - Service 22
DID 6185 - Module
720 → 728 - Every
1 s
Example reply from a 2026 Ford Ranger.
Bits 0 to 7 of the reply, 8 bits.
0xCF = 207 → (207 × 100 ÷ 255) = 81.176471 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2006, 2012 to 2014, 2018 to 2026. In testing for 1988 to 2005, 2007, 2009 to 2011, 2015 to 2017. Not supported for 2008.
Fuel tank level RANGER_FLI_720
Pelican can show this parameter as the fuel tank level.
- Request
22 61 85 - Service 22
DID 6185 - Module
720 → 728 - Every
30 s - Testing for 1988 to 2005, 2007 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2023, 2025 to 2026. Not supported for 2019, 2021 to 2022, 2024.
Fuel tank pressure RANGER_FUEL_TANK_P
- Request
22 16 39 - Service 22
DID 1639 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 6.901311249)- Range
- 0 to 9496.0214 psi
- Unit
- psi
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Fuel temperature RANGER_FUEL_T
- Request
22 05 22 - Service 22
DID 0522 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024.
Fuel › Internal
Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.