Battery parameters
The Ford Ranger has 27 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery age RANGER_12V_AGEConfirmed
- Request
22 40 27 - Service 22
DID 4027 - Module
726 → 72E - Every
3600 s - Testing for 1988 to 2020, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits.
0x0269 = 617 → (617 × 24) = 14,808 h
- Formula
(val × 24)- Range
- 0 to 1572840 h
- Unit
- h
Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.
12V battery current RANGER_VEH_BAT_CURRENTConfirmed
- Request
22 40 2B - Service 22
DID 402B - Module
726 → 72E - Every
1 s - Testing for 1988 to 2020, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 7 of the reply, 8 bits.
0x51 = 81 → (81 − 127) = -46 A
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.
12V battery state of charge RANGER_12V_SOCConfirmed
- Request
22 40 28 - Service 22
DID 4028 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2020, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 7 of the reply, 8 bits.
0x4B = 75 → 75 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.
12V battery temperature RANGER_12V_TConfirmed
- Request
22 40 29 - Service 22
DID 4029 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2020, 2022 to 2026
Example reply from a 2021 Ford Ranger.
Bits 0 to 7 of the reply, 8 bits.
0x4D = 77 → (77 − 40) = 37 °C
- Formula
(val − 40)- Range
- -40 to 100 °C
- Unit
- °C
Confirmed for 2021. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2022, 2024.
12V battery voltage RANGER_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 → 72E - Every
5 s - Testing for 1988 to 2020, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 7 of the reply, 8 bits.
0x7F = 127 → (127 ÷ 20 + 6) = 12.35 V
- Formula
(val ÷ 20 + 6)- Range
- 0 to 18.75 V
- Unit
- V
Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.
Battery capacity too low for start/stop RANGER_BAT_CAP_TOO_LOWConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bit 5 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery current too high for start/stop RANGER_BAT_CURRENT_TOO_HIGHConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bit 2 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery current, predicted RANGER_BAT_CURRENTConfirmed
- Request
22 42 09 - Service 22
DID 4209 - Module
726 → 72E - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 23 of the reply, 24 bits.
0x000047 = 71 → (71 ÷ 4) = 17.75 A
- Formula
(val ÷ 4)- Range
- 0 to 4194303.75 A
- Unit
- A
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery percentage, state of charge RANGER_BAT_PERCENTAGE_ST
- Request
22 40 28 - Service 22
DID 4028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Battery quiescent current, low range RANGER_BAT_QUIESCENTConfirmed
- Request
22 40 25 - Service 22
DID 4025 - Module
726 → 72E - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits.
0x0846 = 2118 → (2118 ÷ 2 − 1000) = 59 mA
- Formula
(val ÷ 2 − 1000)- Range
- -1000 to 31767.5 mA
- Unit
- mA
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery refresh cycle in progress for start/stop RANGER_BAT_REFRESH_CYCLEConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bit 14 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery state detection status RANGER_BAT_ST_DETECTIONConfirmed
- Request
22 42 0A - Service 22
DID 420A - Module
726 → 72E - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 7 of the reply, 8 bits.
0x03 = 3 → 3
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery state of charge too low for start/stop RANGER_BAT_ST_CHG_TOO_LOWConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bit 4 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery temperature too low for auto stop RANGER_BAT_T_TOO_LOW_AUTOConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bit 13 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery voltage RANGER_BAT_V
- Request
22 11 72 - Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.9375 V
- Unit
- V
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Battery voltage too low for auto restart RANGER_BAT_V_TOO_LOW_AUTOConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bit 12 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery voltage too low for cold cranking capability RANGER_BAT_V_TOO_LOW_COLDConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bit 6 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Battery voltage too low for start/stop RANGER_BAT_V_TOO_LOW_STARTConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bit 3 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Charge air cooler temperature RANGER_CHG_AIR_COOLER_T
- Request
22 05 08 - Service 22
DID 0508 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8)- Range
- 0 to 524280
- Unit
- Raw value
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Charge air temperature RANGER_CHG_AIR_T
- Request
22 05 1C - Service 22
DID 051C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Commanded generator voltage RANGER_CMD_GEN_VConfirmed
- Request
22 03 04 - Service 22
DID 0304 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits.
0x54CC = 21708 → (21708 × 0.000488) = 10.593504 V
- Formula
(val × 0.000488)- Range
- 0 to 16 V
- Unit
- V
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2013 to 2014, 2018 to 2026. Supported for 2009, 2011 to 2012.
Normalized cumulative charge when ignition is on RANGER_NORM_CUM_CHG_IGN_ONConfirmed
- Request
22 40 1E - Service 22
DID 401E - Module
726 → 72E - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits.
0x012F = 303 → (303 ÷ 10) = 30.3
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Normalized cumulative discharge from battery with engine off RANGER_NORM_CUM_DCHG_BAT_OFFConfirmed
- Request
22 40 26 - Service 22
DID 4026 - Module
726 → 72E - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits.
0x00C1 = 193 → (193 ÷ 10) = 19.3
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Normalized cumulative discharge from battery with engine on RANGER_NORM_CUM_DCHG_BAT_ONConfirmed
- Request
22 40 21 - Service 22
DID 4021 - Module
726 → 72E - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits.
0x0041 = 65 → (65 ÷ 10) = 6.5
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Second battery current RANGER_VEH_BAT_B_CURRENTConfirmed
- Request
22 42 3C - Service 22
DID 423C - Module
726 → 72E - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0006 = 6 → (6 ÷ 32) = 0.1875 A
- Formula
(val ÷ 32)- Range
- -1024 to 1023.96 A
- Unit
- A
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.
Second battery voltage RANGER_VEH_BAT_B_VConfirmed
- Request
22 41 E8 - Service 22
DID 41E8 - Module
726 → 72E - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Ford Ranger.
Bits 0 to 7 of the reply, 8 bits.
0x80 = 128 → (128 ÷ 20 + 6) = 12.4 V
- Formula
(val ÷ 20 + 6)- Range
- 6 to 18.75 V
- Unit
- V
Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.