Ford Ranger

Climate parameters

The Ford Ranger has 7 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor, state RANGER_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor pressure RANGER_AC_P

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

A/C compressor pressure sensor voltage RANGER_AC_P_SENS_VConfirmed

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

A/C compressor, state RANGER_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

A/C refrigerant pressure RANGER_PCM_A_C_REFRIG_PConfirmed

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x02B2 = 690 → 690 kPa

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012 to 2014, 2018, 2020, 2022, 2024, 2026. Supported for 2011, 2019, 2021, 2023, 2025.

Ambient temperature sensor voltage RANGER_AAT_VConfirmed

  • Request22 03 BA
  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Ambient temperature, alternate RANGER_AAT_ALTConfirmed

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x7C = 124 → (124 ÷ 2 − 40) = 22 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.