Ford F-150

Fuel parameters

The Ford F-150 has 26 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level F150_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 F4 2F
  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1992 to 2009

Example reply from a 2026 Ford F-150.

Bits 0 to 7 of the reply, 8 bits.

0x7A = 122 → (122 × 100 ÷ 255) = 47.843137 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2010 to 2026. In testing for 2009. Not supported for 2005, 2008.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Alcohol fuel percentage ALCH_PCTSAE J1979Confirmed

Indicates the percentage of alcohol contained in ethanol or methanol fuels, if used. For example, ethanol fuel (E85) normally contains 85% ethanol, in which case this parameter will display 85%

  • Request01 52
  • Service 01PID 52
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2018, 2021.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2021 to 2024. Supported for 2012, 2025.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2021 to 2026.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2021 to 2024. Supported for 2012, 2025.

Fuel level F150_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 F4 2F
  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1992 to 2009

Example reply from a 2026 Ford F-150.

Bits 0 to 7 of the reply, 8 bits.

0x7A = 122 → (122 × 100 ÷ 255) = 47.843137 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2010 to 2026. In testing for 2009. Not supported for 2005, 2008.

Fuel level, alternate F150_FLI_ALTConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 61 85
  • Service 22DID 6185
  • Module720 → 728
  • Every5 s
  • Testing for 1992 to 2003, 2005, 2009, 2011 to 2026

Example reply from a 2010 Ford F-150.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2004, 2006 to 2008, 2010. In testing for 1992 to 2001, 2003, 2005, 2009. Not supported for 2002, 2011 to 2024.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2014, 2017 to 2018, 2021 to 2024. Supported for 2002, 2004 to 2008, 2010 to 2013, 2015 to 2016, 2019 to 2020, 2025 to 2026.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2014, 2017 to 2018, 2021 to 2024. Supported for 2002, 2004 to 2008, 2010 to 2013, 2015 to 2016, 2019 to 2020, 2025 to 2026.

Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 71 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2007 to 2008, 2012 to 2025. Supported for 2005 to 2006, 2010 to 2011, 2026.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2021 to 2024. Supported for 2012, 2025.

Fuel › Internal

Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018, 2021 to 2024. Supported for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.