Fuel parameters
The Ford Expedition has 59 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Air/fuel ratio FORD_AIR_FUEL_RATConfirmed
- Request
22 F4 34 - Service 22
DID F434 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2021 Ford Expedition.
Bits 0 to 15 of the reply, 16 bits.
0x6559 = 25945 → (25945 × 0.000446787) = 11.591889
- Formula
(val × 0.000446787)- Range
- 0 to 29.2801
- Unit
- Number
Confirmed for 2021. In testing for 1997 to 2020, 2022 to 2026.
Cylinder 1 fuel balance correction FORD_CYL_1_FUEL_BALANCE
- Request
22 09 8A - Service 22
DID 098A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 1 fuel quantity FORD_CYL_1_FUEL_QTY
- Request
22 04 AA - Service 22
DID 04AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 2 fuel balance correction FORD_CYL_2_FUEL_BALANCE
- Request
22 09 8B - Service 22
DID 098B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 2 fuel quantity FORD_CYL_2_FUEL_QTY
- Request
22 04 AB - Service 22
DID 04AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 3 fuel balance correction FORD_CYL_3_FUEL_BALANCE
- Request
22 09 8C - Service 22
DID 098C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 3 fuel quantity FORD_CYL_3_FUEL_QTY
- Request
22 04 AC - Service 22
DID 04AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 4 fuel balance correction FORD_CYL_4_FUEL_BALANCE
- Request
22 09 8D - Service 22
DID 098D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 4 fuel quantity FORD_CYL_4_FUEL_QTY
- Request
22 04 AD - Service 22
DID 04AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 5 fuel balance correction FORD_CYL_5_FUEL_BALANCE
- Request
22 11 D3 - Service 22
DID 11D3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 5 fuel quantity FORD_CYL_5_FUEL_QTY
- Request
22 04 AE - Service 22
DID 04AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 6 fuel balance correction FORD_CYL_6_FUEL_BALANCE
- Request
22 04 8F - Service 22
DID 048F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 6 fuel quantity FORD_CYL_6_FUEL_QTY
- Request
22 04 AF - Service 22
DID 04AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 7 fuel balance correction FORD_CYL_7_FUEL_BALANCE
- Request
22 04 A6 - Service 22
DID 04A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 7 fuel quantity FORD_CYL_7_FUEL_QTY
- Request
22 04 B0 - Service 22
DID 04B0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 8 fuel balance correction FORD_CYL_8_FUEL_BALANCE
- Request
22 04 A5 - Service 22
DID 04A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Cylinder 8 fuel quantity FORD_CYL_8_FUEL_QTY
- Request
22 04 B1 - Service 22
DID 04B1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
(val ÷ 128000)- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 1997 to 2026.
Dilution of oil with fuel FORD_DILUTION_OIL_FUEL
- Request
22 05 4C - Service 22
DID 054C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1997 to 2026.
Engine fuel rate FORD_ENG_FUEL_RATE
- Request
22 F4 5E - Service 22
DID F45E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 L
- Unit
- L
In testing for 1997 to 2020, 2022 to 2026. Not supported for 2021.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Request
01 5E - Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3212.75 L/h
- Unit
- L/h
Confirmed for 2023 to 2024.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024.
Fuel correction, cylinder 1 FORD_FUEL_CORR_CYL_1
- Request
22 09 8A - Service 22
DID 098A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 1997 to 2026.
Fuel correction, cylinder 2 FORD_FUEL_CORR_CYL_2
- Request
22 09 8B - Service 22
DID 098B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 1997 to 2026.
Fuel correction, cylinder 3 FORD_FUEL_CORR_CYL_3
- Request
22 09 8C - Service 22
DID 098C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 1997 to 2026.
Fuel correction, cylinder 4 FORD_FUEL_CORR_CYL_4
- Request
22 09 8D - Service 22
DID 098D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 1997 to 2026.
Fuel correction, cylinder 5 FORD_FUEL_CORR_CYL_5
- Request
22 11 D3 - Service 22
DID 11D3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 1997 to 2026.
Fuel correction, cylinder 6 FORD_FUEL_CORR_CYL_6
- Request
22 04 8F - Service 22
DID 048F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 1997 to 2026.
Fuel injection impulse width FORD_FUEL_INJ_IMPULSE
- Request
22 16 8B - Service 22
DID 168B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 125000)- Range
- 0 to 0.1 s
- Unit
- s
In testing for 1997 to 2020, 2022 to 2026. Not supported for 2021.
Fuel level FORD_FLIConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 F4 2F - Service 22
DID F42F - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2025 Ford Expedition.
Bits 0 to 7 of the reply, 8 bits.
0x2F = 47 → (47 × 100 ÷ 255) = 18.431373 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2009 to 2010, 2016 to 2025. In testing for 1997 to 2006, 2008, 2011 to 2015, 2026. Not supported for 2007.
Fuel level FORD_FLI_7E0
Pelican can show this parameter as the fuel tank level.
- Request
22 16 C1 - Service 22
DID 16C1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030518509)- Range
- 0 to 200 %
- Unit
- %
In testing for 1997 to 2020, 2022 to 2026. Not supported for 2021.
Fuel pump duty cycle FORD_FUEL_PMP_DUTY
- Request
22 16 72 - Service 22
DID 1672 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25 ÷ 32)- Range
- 0 to 199.2187 %
- Unit
- %
In testing for 1997 to 2020, 2022 to 2026. Not supported for 2021.
Fuel rail pressure control FORD_FUEL_RAIL_P_CTRL
- Request
22 03 C3 - Service 22
DID 03C3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 1997 to 2026.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2007, 2024. Supported for 2006, 2009 to 2010, 2012, 2016 to 2023.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2007, 2024. Supported for 2006, 2009 to 2010, 2012, 2016 to 2023.
Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007, 2017, 2019 to 2022, 2024. Supported for 2006, 2009 to 2010, 2012, 2016, 2018, 2023.
Fuel tank level FORD_FLI_V2Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 61 85 - Service 22
DID 6185 - Module
720 → 728 - Every
1 s - Testing
Example reply from a 2010 Ford Expedition.
Bits 0 to 7 of the reply, 8 bits.
0x7F = 127 → (127 × 100 ÷ 255) = 49.803922 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007, 2009 to 2010. In testing for 1997 to 2006, 2008, 2011 to 2026.
Fuel tank pressure FORD_FUEL_TANK_P
- Request
22 16 39 - Service 22
DID 1639 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 6.901311249)- Range
- 0 to 9496.0214 psi
- Unit
- psi
In testing for 1997 to 2020, 2022 to 2026. Not supported for 2021.
Fuel temperature FORD_FUEL_T
- Request
22 05 22 - Service 22
DID 0522 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2020, 2022 to 2026. Not supported for 2021.
Fuel temperature a FORD_FUEL_T_7E0
- Request
22 04 29 - Service 22
DID 0429 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 1997 to 2026.
Low side fuel rail pressure FORD_LOW_SIDE_FUEL_RAIL_P
- Request
22 06 4E - Service 22
DID 064E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 kPa
- Unit
- kPa
In testing for 1997 to 2026.
Mass fuel, desired FORD_MASS_FUEL_DES
- Request
22 14 12 - Service 22
DID 1412 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095
- Unit
- Number
In testing for 1997 to 2026.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024.
Volume fuel, desired FORD_VOLUME_FUEL_DES
- Request
22 14 11 - Service 22
DID 1411 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095
- Unit
- Number
In testing for 1997 to 2026.
Fuel › Internal
Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.