Ford Expedition

Climate parameters

The Ford Expedition has 10 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor, state FORD_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Example reply from a 2025 Ford Expedition.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2009 to 2010, 2016 to 2021, 2023 to 2025. In testing for 1997 to 2006, 2008, 2011 to 2015, 2022, 2026. Not supported for 2007.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor current FORD_AC_COMP_A

  • Request22 99 AB
  • Service 22DID 99AB
  • Module7C7 → 7CF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 A
Unit
A

In testing for 1997 to 2006, 2008, 2011 to 2015, 2022, 2026. Not supported for 2007, 2009 to 2010, 2016 to 2021, 2023 to 2025.

A/C compressor pressure sensor voltage FORD_AC_P_SENS_VConfirmed

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2009 to 2010, 2016 to 2021, 2023 to 2025. In testing for 1997 to 2006, 2008, 2011 to 2015, 2022, 2026. Not supported for 2007.

A/C compressor, state FORD_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Example reply from a 2025 Ford Expedition.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2009 to 2010, 2016 to 2021, 2023 to 2025. In testing for 1997 to 2006, 2008, 2011 to 2015, 2022, 2026. Not supported for 2007.

A/C refrigerant pressure FORD_PCM_A_C_REFRIG_PConfirmed

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2025 Ford Expedition.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x02BE = 702 → 702 kPa

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2023 to 2025. In testing for 1997 to 2006, 2008, 2011 to 2015, 2022, 2026. Not supported for 2007, 2009 to 2010, 2016 to 2021.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Ambient temperature, alternate FORD_AAT_ALTConfirmed

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Example reply from a 2025 Ford Expedition.

Bits 0 to 7 of the reply, 8 bits.

0x6C = 108 → (108 ÷ 2 − 40) = 14 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2016 to 2021, 2023 to 2025. In testing for 1997 to 2006, 2008, 2011 to 2015, 2022, 2026. Not supported for 2007, 2009 to 2010.

Coolant heater operation mode FORD_COOLANT_HTR_OP_MODE

  • Request22 48 DF
  • Service 22DID 48DF
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2DEGRADEDDegraded
3SHUTDOWNShutdown
4SHORTShort
5NO_RESPONSENo response
6UNKNOWNUnknown
7STOPStop

In testing for 1997 to 2006, 2008, 2011 to 2015, 2022, 2026. Not supported for 2007, 2009 to 2010, 2016 to 2021, 2023 to 2025.

Coolant heater power FORD_COOLANT_HTR_PWR

  • Request22 48 DE
  • Service 22DID 48DE
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 kW
Unit
kW

In testing for 1997 to 2006, 2008, 2011 to 2015, 2022, 2026. Not supported for 2007, 2009 to 2010, 2016 to 2021, 2023 to 2025.

Exterior temperature FORD_AAT

  • Request22 DD 05
  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1997 to 2006, 2008, 2011 to 2015, 2026. Not supported for 2007, 2009 to 2010, 2016 to 2025.

Interior temperature FORD_IAT

  • Request22 DD 04
  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1997 to 2006, 2008, 2011 to 2015, 2026. Not supported for 2007, 2009 to 2010, 2016 to 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.