Dacia Sandero

Drivetrain parameters

The Dacia Sandero has 26 drivetrain parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

2WD mode switch DACIA_2WD_MODE_SW

  • Request22 30 05
  • Service 22DID 3005
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

2WD mode switch DACIA_2WD_MODE_SW

  • Request22 30 05
  • Service 22DID 3005
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

4WD mode monitor DACIA_4WD_MODE_MON

  • Request22 30 24
  • Service 22DID 3024
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

4WD mode switch DACIA_4WD_MODE_SW

  • Request22 30 05
  • Service 22DID 3005
  • Module748
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Auto mode switch DACIA_AUTO_MODE_SW

  • Request22 30 05
  • Service 22DID 3005
  • Module748
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Driving type DACIA_DRIVE_TYPE

  • Request22 4B 3C
  • Service 22DID 4B3C
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Engine torque control DACIA_ENGINE_TORQUE_CTRL

  • Request22 30 10
  • Service 22DID 3010
  • Module748
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Inverter high voltage DACIA_INV_HV_V

  • Request22 20 04
  • Service 22DID 2004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.9687 V
Unit
V

In testing for 2008 to 2026.

Inverter high voltage current DACIA_INV_HV_A

  • Request22 70 49
  • Service 22DID 7049
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32 − 500)
Range
-500 to 1547.9687 A
Unit
A

In testing for 2008 to 2026.

Inverter state DACIA_INV_STATE

  • Request22 21 CF
  • Service 22DID 21CF
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
1OFFOff
2ONOn
3DISCHARGINGDischarging
4ALTERNATORAlternator mode
5SLEEP_READYReady to sleep

In testing for 2008 to 2026.

Inverter temperature DACIA_INV_T

  • Request22 70 0C
  • Service 22DID 700C
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 512 − 40)
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2008 to 2026.

Inverter temperature, power electronics DACIA_INV_T_PEB

  • Request22 33 F6
  • Service 22DID 33F6
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2026.

Motor speed DACIA_MOTOR_RPM

  • Request22 30 64
  • Service 22DID 3064
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2008 to 2026.

Operating mode DACIA_OP_MODE

  • Request22 30 26
  • Service 22DID 3026
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Operating mode, selected DACIA_OP_MODE_SEL

  • Request22 30 23
  • Service 22DID 3023
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Rotor current sensor 1 DACIA_ROTOR_A1

  • Request22 70 03
  • Service 22DID 7003
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 A
Unit
A

In testing for 2008 to 2026.

Rotor current sensor 2 DACIA_ROTOR_A2

  • Request22 70 04
  • Service 22DID 7004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 A
Unit
A

In testing for 2008 to 2026.

Rotor reference resistance DACIA_ROTOR_R

  • Request22 70 50
  • Service 22DID 7050
  • ModuleDADF → DF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.998 Ω
Unit
Ω

In testing for 2008 to 2026.

Rotor temperature, estimated DACIA_ROTOR_T

  • Request22 70 88
  • Service 22DID 7088
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 − 40)
Range
-40 to 471.9921 °C
Unit
°C

In testing for 2008 to 2026.

Rotor temperature, raw DACIA_ROTOR_T_RAW

  • Request22 70 38
  • Service 22DID 7038
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 − 40)
Range
-40 to 471.9921 °C
Unit
°C

In testing for 2008 to 2026.

Stator current, phase U DACIA_STATOR_A_U

  • Request22 70 07
  • Service 22DID 7007
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32 − 500)
Range
-500 to 1547.9687 A
Unit
A

In testing for 2008 to 2026.

Stator current, phase V DACIA_STATOR_A_V

  • Request22 70 08
  • Service 22DID 7008
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32 − 500)
Range
-500 to 1547.9687 A
Unit
A

In testing for 2008 to 2026.

Stator current, phase W DACIA_STATOR_A_W

  • Request22 70 09
  • Service 22DID 7009
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32 − 500)
Range
-500 to 1547.9687 A
Unit
A

In testing for 2008 to 2026.

Stator temperature 1 DACIA_STATOR_T1

  • Request22 70 0F
  • Service 22DID 700F
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 512 − 40)
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2008 to 2026.

Stator temperature 2 DACIA_STATOR_T2

  • Request22 70 10
  • Service 22DID 7010
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 512 − 40)
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2008 to 2026.

Traction control DACIA_TRACTION_CTRL

  • Request22 30 10
  • Service 22DID 3010
  • Module748
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Trajectory control DACIA_TRAJECTORY_CTRL

  • Request22 30 10
  • Service 22DID 3010
  • Module748
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.