Dacia Sandero

Climate parameters

The Dacia Sandero has 18 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor DACIA_AC_COMP

  • Request22 20 1E
  • Service 22DID 201E
  • Module7E0
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor DACIA_AC_COMP

  • Request22 20 1E
  • Service 22DID 201E
  • Module7E0
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

A/C compressor discharge temperature DACIA_COMP_DIS_T

  • Request22 44 0C
  • Service 22DID 440C
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 30)
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

A/C compressor mode DACIA_COMP_MODE

  • Request22 44 02
  • Service 22DID 4402
  • Module744 → 764
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
1ACA/C
2DEICEDe-ice
4HEAT_PUMPHeat pump
6DEMISTDemisting
7IDLEIdle

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

A/C compressor power DACIA_COMP_PWR

  • Request22 44 36
  • Service 22DID 4436
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 W
Unit
W

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

A/C compressor pressure DACIA_COMP_P

  • Request22 43 69
  • Service 22DID 4369
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 bar
Unit
bar

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

A/C compressor speed DACIA_COMP_RPM

  • Request22 43 D8
  • Service 22DID 43D8
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

A/C compressor speed request DACIA_COMP_RPM_REQ

  • Request22 44 04
  • Service 22DID 4404
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

A/C compressor suction temperature DACIA_COMP_SUC_T

  • Request22 44 0D
  • Service 22DID 440D
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 30)
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Ambient air temperature DACIA_AAT

  • Request22 22 18
  • Service 22DID 2218
  • ModuleDADA → DA
  • Every20 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273)
Range
-273 to 6280.5 °C
Unit
°C

In testing for 2008 to 2026.

Cabin temperature DACIA_CABIN_T

  • Request22 40 09
  • Service 22DID 4009
  • Module744 → 764
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 40)
Range
-3316.8 to 3236.7 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Electric heater request DACIA_PTC_REQ

  • Request22 43 41
  • Service 22DID 4341
  • Module744 → 764
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Evaporator temperature DACIA_EVAP_T

  • Request22 40 0A
  • Service 22DID 400A
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Evaporator temperature set point DACIA_EVAP_T_SET

  • Request22 43 68
  • Service 22DID 4368
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Heating condenser temperature DACIA_COND_T

  • Request22 44 29
  • Service 22DID 4429
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256 − 40)
Range
-40 to 215.996 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Heating condenser temperature set point DACIA_COND_T_SET

  • Request22 43 A5
  • Service 22DID 43A5
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512 − 40)
Range
-40 to 87.998 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Heating temperature DACIA_HEAT_T

  • Request22 43 A4
  • Service 22DID 43A4
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256 − 40)
Range
-40 to 215.996 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Refrigerant pressure DACIA_REFRIG_P

  • Request22 22 2A
  • Service 22DID 222A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 bar
Unit
bar

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Refrigerant pressure sensor voltage DACIA_REFRIG_P_SNS_V

  • Request22 20 0D
  • Service 22DID 200D
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.