Dacia Sandero

Battery parameters

The Dacia Sandero has 246 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

AC charging power available DACIA_AC_P_AVAIL

  • Request22 30 0F
  • Service 22DID 300F
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40)
Range
0 to 1638.375 kW
Unit
kW

In testing for 2008 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

AC charging power available DACIA_AC_P_AVAIL

  • Request22 30 0F
  • Service 22DID 300F
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40)
Range
0 to 1638.375 kW
Unit
kW

In testing for 2008 to 2026.

AC mains current DACIA_AC_A

  • Request22 30 0D
  • Service 22DID 300D
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

In testing for 2008 to 2026.

AC mains phases DACIA_AC_PHASES

  • Request22 30 0B
  • Service 22DID 300B
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0ONEOne phase
1TWOTwo phase
2THREEThree phase
3NONENot detected

In testing for 2008 to 2026.

AC mains voltage DACIA_AC_V

  • Request22 2B 8A
  • Service 22DID 2B8A
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 V
Unit
V

In testing for 2008 to 2026.

Battery module 1 temperature DACIA_MOD_T1

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 2 temperature DACIA_MOD_T2

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 3 temperature DACIA_MOD_T3

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 4 temperature DACIA_MOD_T4

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 5 temperature DACIA_MOD_T5

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 6 temperature DACIA_MOD_T6

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 7 temperature DACIA_MOD_T7

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 8 temperature DACIA_MOD_T8

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 9 temperature DACIA_MOD_T9

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 10 temperature DACIA_MOD_T10

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 11 temperature DACIA_MOD_T11

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery module 12 temperature DACIA_MOD_T12

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery voltage, 12V DACIA_12V_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 30 01
  • Service 22DID 3001
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Charge plug present DACIA_PLUG

Pelican can show this parameter as the plug state.

  • Request22 2B 85
  • Service 22DID 2B85
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2008 to 2026.

Charge state DACIA_CHG_STATE

  • Request22 2B 6D
  • Service 22DID 2B6D
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0STOPPEDStopped
1TIMER_WAITWaiting for timer
2DONEDone
3CHARGINGBattery
4INTERRUPTEDInterrupted
5POWER_WAITWaiting for power
6FLAP_OPENCharge flap open
8PREPARINGPreparing

In testing for 2008 to 2026.

Charge type DACIA_CHG_TYPE

  • Request22 2B 7A
  • Service 22DID 2B7A
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNDEFINEDUndefined
1TYPE2Type 2
2TYPE2Type 2
3CHADEMOCHAdeMO
4CCS

In testing for 2008 to 2026.

Complete charge cycles DACIA_CYCLES

  • Request22 92 10
  • Service 22DID 9210
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2026.

Computer supply voltage DACIA_ECU_V

  • Request22 01 2F
  • Service 22DID 012F
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2023.

Energy charged, total DACIA_E_CHG

  • Request22 92 43
  • Service 22DID 9243
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2008 to 2026.

Energy discharged, total DACIA_E_DISCHG

  • Request22 92 45
  • Service 22DID 9245
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2008 to 2026.

Energy regenerated, total DACIA_E_REGEN

  • Request22 92 47
  • Service 22DID 9247
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2008 to 2026.

High voltage battery available energy DACIA_HV_E_AVAIL

  • Request22 91 C8
  • Service 22DID 91C8
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 1000)
Range
0 to 16777.215 kWh
Unit
kWh

In testing for 2008 to 2026.

High voltage battery average temperature DACIA_HV_T

  • Request22 90 12
  • Service 22DID 9012
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

High voltage battery current DACIA_HV_A

Pelican can show this parameter as the traction battery current.

  • Request22 92 5D
  • Service 22DID 925D
  • ModuleDADB → DB
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × -1 ÷ 32 + 1020)
Range
-1027.97 to 1020 A
Unit
A

In testing for 2008 to 2026.

High voltage battery current DACIA_HV_A_3042

  • Request22 30 42
  • Service 22DID 3042
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 16383.75)
Range
-16383.75 to 16383.75 A
Unit
A

In testing for 2008 to 2026.

High voltage battery current, power electronics DACIA_HV_A_PEB

  • Request22 32 04
  • Service 22DID 3204
  • Module7E4 → 7EC
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4 − 8192)
Range
-8192 to 8191.75 A
Unit
A

In testing for 2008 to 2026.

High voltage battery current, vehicle controller DACIA_HV_A_EVC

  • Request22 21 CC
  • Service 22DID 21CC
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4 − 500)
Range
-500 to 15883.75 A
Unit
A

In testing for 2008 to 2026.

High voltage battery voltage DACIA_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 90 05
  • Service 22DID 9005
  • ModuleDADB → DB
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

In testing for 2008 to 2026.

High voltage battery voltage, power electronics DACIA_HV_V_PEB

  • Request22 32 03
  • Service 22DID 3203
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 V
Unit
V

In testing for 2008 to 2026.

High voltage battery voltage, vehicle controller DACIA_HV_V_EVC

  • Request22 20 FE
  • Service 22DID 20FE
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

In testing for 2008 to 2026.

Maximum charge power DACIA_CHG_P_MAX

  • Request22 90 18
  • Service 22DID 9018
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 kW
Unit
kW

In testing for 2008 to 2026.

Pack temperature 1 DACIA_PACK_T1

  • Request22 91 31
  • Service 22DID 9131
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 2 DACIA_PACK_T2

  • Request22 91 32
  • Service 22DID 9132
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 3 DACIA_PACK_T3

  • Request22 91 33
  • Service 22DID 9133
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 4 DACIA_PACK_T4

  • Request22 91 34
  • Service 22DID 9134
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 5 DACIA_PACK_T5

  • Request22 91 35
  • Service 22DID 9135
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 6 DACIA_PACK_T6

  • Request22 91 36
  • Service 22DID 9136
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 7 DACIA_PACK_T7

  • Request22 91 37
  • Service 22DID 9137
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 8 DACIA_PACK_T8

  • Request22 91 38
  • Service 22DID 9138
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 9 DACIA_PACK_T9

  • Request22 91 39
  • Service 22DID 9139
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 10 DACIA_PACK_T10

  • Request22 91 3A
  • Service 22DID 913A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 11 DACIA_PACK_T11

  • Request22 91 3B
  • Service 22DID 913B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

Pack temperature 12 DACIA_PACK_T12

  • Request22 91 3C
  • Service 22DID 913C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2008 to 2026.

State of charge DACIA_SOC

Pelican can show this parameter as the state of charge.

  • Request22 90 02
  • Service 22DID 9002
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2008 to 2026.

State of charge DACIA_SOC_9002

  • Request22 90 02
  • Service 22DID 9002
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2008 to 2026.

State of charge, battery controller DACIA_SOC_9001

  • Request22 90 01
  • Service 22DID 9001
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2008 to 2026.

State of charge, vehicle controller DACIA_SOC_EVC

  • Request22 20 02
  • Service 22DID 2002
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 %
Unit
%

In testing for 2008 to 2026.

State of health DACIA_SOH

Pelican can show this parameter as the state of health.

  • Request22 90 03
  • Service 22DID 9003
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2008 to 2026.

Supply voltage, ECU DACIA_ECU_SUPPLY_V

  • Request22 20 05
  • Service 22DID 2005
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Battery › Cells

Cell 1 voltage DACIA_CELL_V1

  • Request22 90 21
  • Service 22DID 9021
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 1 voltage DACIA_CELL1_V1

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 2 voltage DACIA_CELL_V2

  • Request22 90 22
  • Service 22DID 9022
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 2 voltage DACIA_CELL1_V2

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 3 voltage DACIA_CELL_V3

  • Request22 90 23
  • Service 22DID 9023
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 3 voltage DACIA_CELL1_V3

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 4 voltage DACIA_CELL_V4

  • Request22 90 24
  • Service 22DID 9024
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 4 voltage DACIA_CELL1_V4

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 5 voltage DACIA_CELL_V5

  • Request22 90 25
  • Service 22DID 9025
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 5 voltage DACIA_CELL1_V5

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 6 voltage DACIA_CELL_V6

  • Request22 90 26
  • Service 22DID 9026
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 6 voltage DACIA_CELL1_V6

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 7 voltage DACIA_CELL_V7

  • Request22 90 27
  • Service 22DID 9027
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 7 voltage DACIA_CELL1_V7

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 8 voltage DACIA_CELL_V8

  • Request22 90 28
  • Service 22DID 9028
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 8 voltage DACIA_CELL1_V8

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 9 voltage DACIA_CELL_V9

  • Request22 90 29
  • Service 22DID 9029
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 9 voltage DACIA_CELL1_V9

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 10 voltage DACIA_CELL_V10

  • Request22 90 2A
  • Service 22DID 902A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 10 voltage DACIA_CELL1_V10

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 11 voltage DACIA_CELL_V11

  • Request22 90 2B
  • Service 22DID 902B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 11 voltage DACIA_CELL1_V11

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 12 voltage DACIA_CELL_V12

  • Request22 90 2C
  • Service 22DID 902C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 12 voltage DACIA_CELL1_V12

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 13 voltage DACIA_CELL_V13

  • Request22 90 2D
  • Service 22DID 902D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 13 voltage DACIA_CELL1_V13

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 14 voltage DACIA_CELL_V14

  • Request22 90 2E
  • Service 22DID 902E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 14 voltage DACIA_CELL1_V14

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 15 voltage DACIA_CELL_V15

  • Request22 90 2F
  • Service 22DID 902F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 15 voltage DACIA_CELL1_V15

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 16 voltage DACIA_CELL_V16

  • Request22 90 30
  • Service 22DID 9030
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 16 voltage DACIA_CELL1_V16

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 17 voltage DACIA_CELL_V17

  • Request22 90 31
  • Service 22DID 9031
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 17 voltage DACIA_CELL1_V17

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 18 voltage DACIA_CELL_V18

  • Request22 90 32
  • Service 22DID 9032
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 18 voltage DACIA_CELL1_V18

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 19 voltage DACIA_CELL_V19

  • Request22 90 33
  • Service 22DID 9033
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 19 voltage DACIA_CELL1_V19

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 20 voltage DACIA_CELL_V20

  • Request22 90 34
  • Service 22DID 9034
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 20 voltage DACIA_CELL1_V20

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 21 voltage DACIA_CELL_V21

  • Request22 90 35
  • Service 22DID 9035
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 21 voltage DACIA_CELL1_V21

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 22 voltage DACIA_CELL_V22

  • Request22 90 36
  • Service 22DID 9036
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 22 voltage DACIA_CELL1_V22

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 23 voltage DACIA_CELL_V23

  • Request22 90 37
  • Service 22DID 9037
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 23 voltage DACIA_CELL1_V23

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 24 voltage DACIA_CELL_V24

  • Request22 90 38
  • Service 22DID 9038
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 24 voltage DACIA_CELL1_V24

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 25 voltage DACIA_CELL_V25

  • Request22 90 39
  • Service 22DID 9039
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 25 voltage DACIA_CELL1_V25

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 26 voltage DACIA_CELL_V26

  • Request22 90 3A
  • Service 22DID 903A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 26 voltage DACIA_CELL1_V26

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 27 voltage DACIA_CELL_V27

  • Request22 90 3B
  • Service 22DID 903B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 27 voltage DACIA_CELL1_V27

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 28 voltage DACIA_CELL_V28

  • Request22 90 3C
  • Service 22DID 903C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 28 voltage DACIA_CELL1_V28

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 29 voltage DACIA_CELL_V29

  • Request22 90 3D
  • Service 22DID 903D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 29 voltage DACIA_CELL1_V29

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 30 voltage DACIA_CELL_V30

  • Request22 90 3E
  • Service 22DID 903E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 30 voltage DACIA_CELL1_V30

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 31 voltage DACIA_CELL_V31

  • Request22 90 3F
  • Service 22DID 903F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 31 voltage DACIA_CELL1_V31

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 32 voltage DACIA_CELL_V32

  • Request22 90 41
  • Service 22DID 9041
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 32 voltage DACIA_CELL1_V32

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 33 voltage DACIA_CELL_V33

  • Request22 90 42
  • Service 22DID 9042
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 33 voltage DACIA_CELL1_V33

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 34 voltage DACIA_CELL_V34

  • Request22 90 43
  • Service 22DID 9043
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 34 voltage DACIA_CELL1_V34

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 35 voltage DACIA_CELL_V35

  • Request22 90 44
  • Service 22DID 9044
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 35 voltage DACIA_CELL1_V35

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 36 voltage DACIA_CELL_V36

  • Request22 90 45
  • Service 22DID 9045
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 36 voltage DACIA_CELL1_V36

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 37 voltage DACIA_CELL_V37

  • Request22 90 46
  • Service 22DID 9046
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 37 voltage DACIA_CELL1_V37

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 38 voltage DACIA_CELL_V38

  • Request22 90 47
  • Service 22DID 9047
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 38 voltage DACIA_CELL1_V38

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 39 voltage DACIA_CELL_V39

  • Request22 90 48
  • Service 22DID 9048
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 39 voltage DACIA_CELL1_V39

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 40 voltage DACIA_CELL_V40

  • Request22 90 49
  • Service 22DID 9049
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 40 voltage DACIA_CELL1_V40

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 41 voltage DACIA_CELL_V41

  • Request22 90 4A
  • Service 22DID 904A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 41 voltage DACIA_CELL1_V41

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 42 voltage DACIA_CELL_V42

  • Request22 90 4B
  • Service 22DID 904B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 42 voltage DACIA_CELL1_V42

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 43 voltage DACIA_CELL_V43

  • Request22 90 4C
  • Service 22DID 904C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 43 voltage DACIA_CELL1_V43

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 44 voltage DACIA_CELL_V44

  • Request22 90 4D
  • Service 22DID 904D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 44 voltage DACIA_CELL1_V44

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 45 voltage DACIA_CELL_V45

  • Request22 90 4E
  • Service 22DID 904E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 45 voltage DACIA_CELL1_V45

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 46 voltage DACIA_CELL_V46

  • Request22 90 4F
  • Service 22DID 904F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 46 voltage DACIA_CELL1_V46

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 47 voltage DACIA_CELL_V47

  • Request22 90 50
  • Service 22DID 9050
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 47 voltage DACIA_CELL1_V47

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 48 voltage DACIA_CELL_V48

  • Request22 90 51
  • Service 22DID 9051
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 48 voltage DACIA_CELL1_V48

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 49 voltage DACIA_CELL_V49

  • Request22 90 52
  • Service 22DID 9052
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 49 voltage DACIA_CELL1_V49

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 50 voltage DACIA_CELL_V50

  • Request22 90 53
  • Service 22DID 9053
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 50 voltage DACIA_CELL1_V50

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 51 voltage DACIA_CELL_V51

  • Request22 90 54
  • Service 22DID 9054
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 51 voltage DACIA_CELL1_V51

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 52 voltage DACIA_CELL_V52

  • Request22 90 55
  • Service 22DID 9055
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 52 voltage DACIA_CELL1_V52

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 53 voltage DACIA_CELL_V53

  • Request22 90 56
  • Service 22DID 9056
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 53 voltage DACIA_CELL1_V53

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 54 voltage DACIA_CELL_V54

  • Request22 90 57
  • Service 22DID 9057
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 54 voltage DACIA_CELL1_V54

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 55 voltage DACIA_CELL_V55

  • Request22 90 58
  • Service 22DID 9058
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 55 voltage DACIA_CELL1_V55

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 56 voltage DACIA_CELL_V56

  • Request22 90 59
  • Service 22DID 9059
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 56 voltage DACIA_CELL1_V56

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 57 voltage DACIA_CELL_V57

  • Request22 90 5A
  • Service 22DID 905A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 57 voltage DACIA_CELL1_V57

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 58 voltage DACIA_CELL_V58

  • Request22 90 5B
  • Service 22DID 905B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 58 voltage DACIA_CELL1_V58

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 59 voltage DACIA_CELL_V59

  • Request22 90 5C
  • Service 22DID 905C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 59 voltage DACIA_CELL1_V59

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 60 voltage DACIA_CELL_V60

  • Request22 90 5D
  • Service 22DID 905D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 60 voltage DACIA_CELL1_V60

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 61 voltage DACIA_CELL_V61

  • Request22 90 5E
  • Service 22DID 905E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 61 voltage DACIA_CELL1_V61

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 62 voltage DACIA_CELL_V62

  • Request22 90 5F
  • Service 22DID 905F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 62 voltage DACIA_CELL1_V62

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 63 voltage DACIA_CELL_V63

  • Request22 90 61
  • Service 22DID 9061
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 63 voltage DACIA_CELL1_V63

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 64 voltage DACIA_CELL_V64

  • Request22 90 62
  • Service 22DID 9062
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 64 voltage DACIA_CELL1_V64

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 65 voltage DACIA_CELL_V65

  • Request22 90 63
  • Service 22DID 9063
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 65 voltage DACIA_CELL1_V65

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 66 voltage DACIA_CELL_V66

  • Request22 90 64
  • Service 22DID 9064
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 66 voltage DACIA_CELL1_V66

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 67 voltage DACIA_CELL_V67

  • Request22 90 65
  • Service 22DID 9065
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 67 voltage DACIA_CELL1_V67

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 68 voltage DACIA_CELL_V68

  • Request22 90 66
  • Service 22DID 9066
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 68 voltage DACIA_CELL1_V68

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 69 voltage DACIA_CELL_V69

  • Request22 90 67
  • Service 22DID 9067
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 69 voltage DACIA_CELL1_V69

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 70 voltage DACIA_CELL_V70

  • Request22 90 68
  • Service 22DID 9068
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 70 voltage DACIA_CELL1_V70

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 71 voltage DACIA_CELL_V71

  • Request22 90 69
  • Service 22DID 9069
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 71 voltage DACIA_CELL1_V71

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 72 voltage DACIA_CELL_V72

  • Request22 90 6A
  • Service 22DID 906A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 72 voltage DACIA_CELL1_V72

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 73 voltage DACIA_CELL_V73

  • Request22 90 6B
  • Service 22DID 906B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 73 voltage DACIA_CELL1_V73

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 74 voltage DACIA_CELL_V74

  • Request22 90 6C
  • Service 22DID 906C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 74 voltage DACIA_CELL1_V74

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 75 voltage DACIA_CELL_V75

  • Request22 90 6D
  • Service 22DID 906D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 75 voltage DACIA_CELL1_V75

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 76 voltage DACIA_CELL_V76

  • Request22 90 6E
  • Service 22DID 906E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 76 voltage DACIA_CELL1_V76

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 77 voltage DACIA_CELL_V77

  • Request22 90 6F
  • Service 22DID 906F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 77 voltage DACIA_CELL1_V77

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 78 voltage DACIA_CELL_V78

  • Request22 90 70
  • Service 22DID 9070
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 78 voltage DACIA_CELL1_V78

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 79 voltage DACIA_CELL_V79

  • Request22 90 71
  • Service 22DID 9071
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 79 voltage DACIA_CELL1_V79

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 80 voltage DACIA_CELL_V80

  • Request22 90 72
  • Service 22DID 9072
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 80 voltage DACIA_CELL1_V80

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 81 voltage DACIA_CELL_V81

  • Request22 90 73
  • Service 22DID 9073
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 81 voltage DACIA_CELL1_V81

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 82 voltage DACIA_CELL_V82

  • Request22 90 74
  • Service 22DID 9074
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 82 voltage DACIA_CELL1_V82

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 83 voltage DACIA_CELL_V83

  • Request22 90 75
  • Service 22DID 9075
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 83 voltage DACIA_CELL1_V83

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 84 voltage DACIA_CELL_V84

  • Request22 90 76
  • Service 22DID 9076
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 84 voltage DACIA_CELL1_V84

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 85 voltage DACIA_CELL_V85

  • Request22 90 77
  • Service 22DID 9077
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 85 voltage DACIA_CELL1_V85

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 86 voltage DACIA_CELL_V86

  • Request22 90 78
  • Service 22DID 9078
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 86 voltage DACIA_CELL1_V86

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 87 voltage DACIA_CELL_V87

  • Request22 90 79
  • Service 22DID 9079
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 87 voltage DACIA_CELL1_V87

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 88 voltage DACIA_CELL_V88

  • Request22 90 7A
  • Service 22DID 907A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 88 voltage DACIA_CELL1_V88

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 89 voltage DACIA_CELL_V89

  • Request22 90 7B
  • Service 22DID 907B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 89 voltage DACIA_CELL1_V89

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 90 voltage DACIA_CELL_V90

  • Request22 90 7C
  • Service 22DID 907C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 90 voltage DACIA_CELL1_V90

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 91 voltage DACIA_CELL_V91

  • Request22 90 7D
  • Service 22DID 907D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 91 voltage DACIA_CELL1_V91

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 92 voltage DACIA_CELL_V92

  • Request22 90 7E
  • Service 22DID 907E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 92 voltage DACIA_CELL1_V92

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 93 voltage DACIA_CELL_V93

  • Request22 90 7F
  • Service 22DID 907F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 93 voltage DACIA_CELL1_V93

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 94 voltage DACIA_CELL_V94

  • Request22 90 81
  • Service 22DID 9081
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 94 voltage DACIA_CELL1_V94

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 95 voltage DACIA_CELL_V95

  • Request22 90 82
  • Service 22DID 9082
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 95 voltage DACIA_CELL1_V95

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Cell 96 voltage DACIA_CELL_V96

  • Request22 90 83
  • Service 22DID 9083
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2008 to 2026.

Cell 96 voltage DACIA_CELL1_V96

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.