Cupra Leon

Engine parameters

The Cupra Leon has 1,108 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Oil temperature CUPRA_PQ35_OIL_TConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 20 2F
  • Service 22DID 202F
  • Module714 → 77E
  • Every30 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x66 = 102 → (102 − 58) = 44 °C

Formula
(val − 58)
Range
-58 to 197 °C
Unit
°C

Confirmed for 2021. In testing for 2022. Not supported for 2020, 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C clutch CUPRA_CLIMATE_A_C_CLCH

  • Request22 48 2B
  • Service 22DID 482B
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

A/C compressor load CUPRA_CLIMATE_A_C_COMP_LOAD

  • Request22 26 04
  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 N·m
Unit
N·m

In testing for 2020 to 2026.

A/C compressor torque CUPRA_A_C_COMPRESSOR_TORQUE

  • Request22 10 1A
  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

A/C compressor torque CUPRA_A_C_COMPRESSOR_TORQUE_V2

  • Request22 10 1A
  • Service 22DID 101A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

A/C refrigerant pressure CUPRA_A_C_REFRIGERANT_PRES

  • Request22 10 17
  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2)
Range
-65536 to 65534
Unit
Raw value

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

A/C refrigerant pressure CUPRA_A_C_REFRIGERANT_PRES_V2

  • Request22 10 17
  • Service 22DID 1017
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2)
Range
-65536 to 65534
Unit
Raw value

In testing for 2020 to 2026.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2023, 2025. Supported for 2020 to 2021, 2024, 2026.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2023, 2025. Supported for 2026.

Actual turbo boost CUPRA_ACT_TURBO_BOOST

  • Request22 11 F0
  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2 bar
Unit
bar

In testing for 2020 to 2026.

Adaptation of loss torque CUPRA_ADPT_LOSS_TQ

  • Request22 29 29
  • Service 22DID 2929
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Adaptation of throttle valve CUPRA_ADPT_THROTTLE_VLV

  • Request22 29 2B
  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Adaptation val.cylinder1 fast diagnosis CUPRA_ADPT_VAL_CYL1_FAST

  • Request22 3F 45
  • Service 22DID 3F45
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2020 to 2026.

Adaptation val.cylinder1 slow diagnosis CUPRA_ADPT_VAL_CYL1_SLOW

  • Request22 3F 41
  • Service 22DID 3F41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2020 to 2026.

Adaptation val.cylinder2 fast diagnosis CUPRA_ADPT_VAL_CYL2_FAST

  • Request22 3F 48
  • Service 22DID 3F48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2020 to 2026.

Adaptation val.cylinder2 slow diagnosis CUPRA_ADPT_VAL_CYL2_SLOW

  • Request22 3F 44
  • Service 22DID 3F44
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2020 to 2026.

Adaptation val.cylinder3 fast diagnosis CUPRA_ADPT_VAL_CYL3_FAST

  • Request22 3F 46
  • Service 22DID 3F46
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2020 to 2026.

Adaptation val.cylinder3 slow diagnosis CUPRA_ADPT_VAL_CYL3_SLOW

  • Request22 3F 42
  • Service 22DID 3F42
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2020 to 2026.

Adaptation val.cylinder4 fast diagnosis CUPRA_ADPT_VAL_CYL4_FAST

  • Request22 3F 47
  • Service 22DID 3F47
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2020 to 2026.

Adaptation val.cylinder4 slow diagnosis CUPRA_ADPT_VAL_CYL4_SLOW

  • Request22 3F 43
  • Service 22DID 3F43
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2020 to 2026.

Adaptive mode CUPRA_ADAPTIVE_MODE

  • Request22 10 11
  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Air conditioning compressor pressure, linear raw value CUPRA_AC_COMP_P_LINEAR_RAW

  • Request22 15 C7
  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070
Unit
Raw value

In testing for 2020 to 2026.

Air conditioning compressor refrigerant pressure CUPRA_AC_COMP_REFRIGERANT_P

  • Request22 10 48
  • Service 22DID 1048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2)
Range
-65536 to 65534
Unit
Raw value

In testing for 2020 to 2026.

Air conditioning compressor torque CUPRA_AC_COMP_TQ

  • Request22 10 4B
  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Air conditioning compressor torque CUPRA_AC_COMP_TQ_V2

  • Request22 10 23
  • Service 22DID 1023
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Air conditioning compressor torque CUPRA_AC_COMP_TQ_V4

  • Request22 20 17
  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 N·m
Unit
N·m

In testing for 2020 to 2026.

Air conditioning refrigerant pressure CUPRA_AC_REFRIGERANT_P

  • Request22 41 2A
  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2)
Range
-65536 to 65534
Unit
Raw value

In testing for 2020 to 2026.

Air filling CUPRA_AIR_FILLING

  • Request22 12 1C
  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 11719 ÷ 500000)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Air intake vacuum CUPRA_AIR_VAC

  • Request22 18 16
  • Service 22DID 1816
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Air leakage CUPRA_AIR_LEAKAGE

  • Request22 11 B8
  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Air mass CUPRA_AIR_MASS

  • Request22 13 CD
  • Service 22DID 13CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047
Unit
Raw value

In testing for 2020 to 2026.

Air mass meter 1 CUPRA_MQB_AIR_MASS_1

  • Request22 10 24
  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Air mass, actual value, mg/stroke CUPRA_AIR_MASS_ACT_MG

  • Request22 29 D1
  • Service 22DID 29D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020 to 2026.

Air mass, specified value CUPRA_AIR_MASS_SPEC

  • Request22 10 4C
  • Service 22DID 104C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2020 to 2026.

Air pollution level CUPRA_CLIMATE_AIR_POLUTION_LVLConfirmed

  • Request22 26 ED
  • Service 22DID 26ED
  • Module746 → 7B0
  • Every5 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x0D = 13 → (13 ÷ 10) = 1.3

Formula
(val ÷ 10)
Range
-12.8 to 12.7
Unit
Number

Confirmed for 2021, 2023 to 2026. In testing for 2020, 2022.

All-wheel drive temperature CUPRA_PQ35_HAL_T

  • Request22 2B F1
  • Service 22DID 2BF1
  • Module70F → 779
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 100 − 227.67)
Range
-40 to 200 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

All-wheel-drive pump current CUPRA_AWD_PMP_CURRENT

  • Request22 2B 0D
  • Service 22DID 2B0D
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9563 ÷ 25500 − 47.63)
Range
-47.63 to 47.9999 A
Unit
A

In testing for 2020 to 2026.

Alternator load CUPRA_ALTERNATOR_LOAD

  • Request22 10 24
  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 W
Unit
W

In testing for 2020 to 2026.

Ambient air pressure CUPRA_AMBIENT_AIR_P

  • Request22 15 09
  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 39 ÷ 1000)
Range
0 to 2555.8649
Unit
Raw value

In testing for 2020 to 2026.

Ambient air temperature CUPRA_DASH_AMBIENT_AIR_TConfirmed

  • Request22 10 14
  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x86 = 134 → (134 ÷ 2 − 50) = 17 °C

Formula
(val ÷ 2 − 50)
Range
-50 to 77.5 °C
Unit
°C

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Ambient air temperature, v1 CUPRA_AAT_V1

  • Request22 14 F8
  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.18 − 460)
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Ambient temperature CUPRA_AAT_7E0

  • Request22 11 23
  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Ambient temperature CUPRA_AAT_7E0_2

  • Request22 10 00
  • Service 22DID 1000
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2020 to 2026.

Analysis-39 driving recorder total time CUPRA_ANALYSIS_39_DRIVING

  • Request22 10 AF
  • Service 22DID 10AF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 5)
Range
0 to 858993459 s
Unit
s

In testing for 2020 to 2026.

Analysis, clutch 1, maximum temperature CUPRA_ANALYSIS_CLU_1_MAX_T

  • Request22 10 64
  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Analysis, clutch 2, maximum temperature CUPRA_ANALYSIS_CLU_2_MAX_T

  • Request22 10 79
  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Automatic engine starts counter CUPRA_AUTOMATIC_ENG_STARTS

  • Request22 29 99
  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Automatic transmission fluid temperature, lifetime max CUPRA_ATF_MAX

  • Request22 70 4F
  • Service 22DID 704F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Automatic transmission fluid temperature, variant 2 CUPRA_MQB_TCM_ATF_T_VAR_2_DSG_S_TRONICConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 21 04
  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2022. Not supported for 2020, 2024 to 2026.

Aux. hydraulic pump internal temperature CUPRA_AUX_HYDRAULIC_PMP_T

  • Request22 51 A6
  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Aux. hydraulic pump, current CUPRA_AUX_HYDRAULIC_PMP

  • Request22 4E 76
  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 A
Unit
A

In testing for 2020 to 2026.

Average ignition timing angle delay adjustment CUPRA_AVG_IGN_TIM_ANG

  • Request22 29 49
  • Service 22DID 2949
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °
Unit
°

In testing for 2020 to 2026.

Avg. injection time CUPRA_AVG_INJ_TIME

  • Request22 12 8C
  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 2500)
Range
0 to 1717986 ms
Unit
ms

In testing for 2020 to 2026.

Avg. injection time CUPRA_AVG_INJ_TIME_7E0

  • Request22 20 03
  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25 ms
Unit
ms

In testing for 2020 to 2026.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023. Supported for 2021, 2024 to 2026.

Barometric pressure CUPRA_BAROMETRIC_P

  • Request22 15 09
  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 kPa
Unit
kPa

In testing for 2020 to 2026.

Basic correction factor:, cylinder 1, filtered CUPRA_BASIC_CORR_FACTOR_1

  • Request22 17 1A
  • Service 22DID 171A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 7999 ÷ 65535000)
Range
0 to 7.999
Unit
Number

In testing for 2020 to 2026.

Basic correction factor:, cylinder 2, filtered CUPRA_BASIC_CORR_FACTOR_2

  • Request22 17 1D
  • Service 22DID 171D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 7999 ÷ 65535000)
Range
0 to 7.999
Unit
Number

In testing for 2020 to 2026.

Basic correction factor:, cylinder 3, filtered CUPRA_BASIC_CORR_FACTOR_3

  • Request22 17 1B
  • Service 22DID 171B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 7999 ÷ 65535000)
Range
0 to 7.999
Unit
Number

In testing for 2020 to 2026.

Basic correction factor:, cylinder 4, filtered CUPRA_BASIC_CORR_FACTOR_4

  • Request22 17 1C
  • Service 22DID 171C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 7999 ÷ 65535000)
Range
0 to 7.999
Unit
Number

In testing for 2020 to 2026.

BMC-E temperature, 1 CUPRA_BMS_BMCE_T1

  • Request22 18 0C
  • Service 22DID 180C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

BMC-E temperature, 2 CUPRA_BMS_BMCE_T2

  • Request22 18 0D
  • Service 22DID 180D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

BMC-E temperature, 3 CUPRA_BMS_BMCE_T3Confirmed

  • Request22 18 0E
  • Service 22DID 180E
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → (1 − 50) = -49 °C

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2021. In testing for 2022. Not supported for 2020, 2023 to 2026.

BMC-E temperature, 4 CUPRA_BMS_BMCE_T_CAN

  • Request22 18 10
  • Service 22DID 1810
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 205 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Boost press before throttle: calculated actual value CUPRA_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT

  • Request22 18 1A
  • Service 22DID 181A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2500)
Range
-81920000 to 81917500
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Boost pressure actuator, commanded duty CUPRA_BOOST_P_ACTUATOR_CMD

  • Request22 16 EE
  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.0122068184)
Range
-399.993 to 100 %
Unit
%

In testing for 2020 to 2026.

Boost pressure commanded CUPRA_BOOST_P_CMD

  • Request22 11 49
  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2023.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2023.

Boost pressure, actual CUPRA_BOOST_P_ACT

  • Request22 11 F0
  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119.9218
Unit
Raw value

In testing for 2020 to 2026.

Boost pressure, actual CUPRA_BOOST_P_ACT_V2

  • Request22 11 1E
  • Service 22DID 111E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 25)
Range
0 to 5242
Unit
Raw value

In testing for 2020 to 2026.

Boost pressure, target CUPRA_BOOST_P_TGT

  • Request22 11 18
  • Service 22DID 1118
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550
Unit
Raw value

In testing for 2020 to 2026.

Boost regulation duty, commanded value CUPRA_BOOST_REGULATION_CMD

  • Request22 12 19
  • Service 22DID 1219
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0234384354)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Boost regulator feedback CUPRA_BOOST_REGULATOR

  • Request22 11 CC
  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Boost regulator feedback CUPRA_BOOST_REGULATOR_FEEDBACK

  • Request22 11 CC
  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Break pressure CUPRA_BREAK_P

  • Request22 2B 21
  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 152999 ÷ 10000000 − 42.503)
Range
-543 to 458 bar
Unit
bar

In testing for 2020 to 2026.

Bypass valve high pressure turbine inlet, activation CUPRA_BYPASS_VLV_HIGH_P_TURBINE_INLET_V2

  • Request22 39 FF
  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2020 to 2026.

Bypass valve high pressure turbine inlet, activation CUPRA_BYPASS_VLV_HIGH_P_V2

  • Request22 39 FF
  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Bypass valve high pressure turbine inlet, actual value CUPRA_BYPASS_VLV_HIGH_P_ACT

  • Request22 39 FC
  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 25 ÷ 2048)
Range
-400 to 399 %
Unit
%

In testing for 2020 to 2026.

Bypass valve high pressure turbine inlet, offset closed CUPRA_BYPASS_VLV_HIGH_P

  • Request22 39 FD
  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.012207)
Range
-399.9989 to 100 %
Unit
%

In testing for 2020 to 2026.

Bypass valve high pressure turbine inlet, offset closed CUPRA_BYPASS_VLV_HIGH_P_TURBINE

  • Request22 39 FD
  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.012207)
Range
-399 to 399 %
Unit
%

In testing for 2020 to 2026.

Bypass valve high pressure turbine inlet, offset open CUPRA_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Request22 39 FE
  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.012207)
Range
-399 to 399 %
Unit
%

In testing for 2020 to 2026.

Bypass valve high pressure turbine inlet, offset open CUPRA_BYPASS_VLV_HIGH_P_TURBINE_V2

  • Request22 39 FE
  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.012207)
Range
-399.9989 to 100 %
Unit
%

In testing for 2020 to 2026.

Bypass valve high pressure turbine inlet, target value CUPRA_BYPASS_VLV_HIGH_P_TGT

  • Request22 39 FB
  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 25 ÷ 2048)
Range
-400 to 399 %
Unit
%

In testing for 2020 to 2026.

Bze_q_elad CUPRA_BZE_Q_ELAD

  • Request22 12 3A
  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2020 to 2026.

Bze_q_lad CUPRA_BZE_Q_LAD

  • Request22 12 3A
  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2020 to 2026.

Cabin temperature CUPRA_C7_CABIN_T

  • Request22 26 13
  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 256)
Range
-128 to 127.99 °C
Unit
°C

In testing for 2020 to 2026.

Cabin temperature CUPRA_CABIN_TConfirmed

  • Request22 26 13
  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0133 = 307 → (307 ÷ 10) = 30.7 °C

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023 to 2026. Supported for 2020.

Calculated oil temperature CUPRA_PQ35_CALCULATED_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request22 20 A1
  • Service 22DID 20A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Camshaft adaptation exhaust bank 1, phase position CUPRA_CAM_ADPT_EXH_BANK_1_PHASE

  • Request22 20 23
  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2020 to 2026.

Camshaft adaptation intake bank 1, phase position CUPRA_CAM_ADPT_INT_BANK_1_PHASE

  • Request22 12 FE
  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2020 to 2026.

Camshaft adaptation intake bank 1, phase position CUPRA_CAM_ADPT_INT_BANK_1_PHASE_V2

  • Request22 20 21
  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2020 to 2026.

Camshaft adaptation intake, phase position CUPRA_CAM_ADPT_INT_PHASE

  • Request22 10 93
  • Service 22DID 1093
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 35999 ÷ 1638350)
Range
-720 to 719 °
Unit
°

In testing for 2020 to 2026.

Camshaft adaptation, counter due to knock CUPRA_CAM_ADPT_CNT_KNOCK

  • Request22 52 3B
  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Camshaft adaptation, exhaust bank 1, phase position CUPRA_CAM_ADPT_EXH_BANK_1

  • Request22 11 28
  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020 to 2026.

Camshaft adaptation, intake bank 1, phase position CUPRA_CAM_ADPT_INT_BANK_1

  • Request22 11 25
  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020 to 2026.

Camshaft adaptation, intake deviation CUPRA_CAM_ADPT_INT_DEV

  • Request22 4F F5
  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 128)
Range
-256 to 255.9921 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment intake bank 1, activation % CUPRA_CAM_ADJ_INT_BANK_1

  • Request22 29 30
  • Service 22DID 2930
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Camshaft adjustment intake test bank 1 CUPRA_CAM_ADJ_INT_TEST_1

  • Request22 39 3C
  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Camshaft adjustment outlet test bank 1 CUPRA_CAM_ADJ_OUTLET_TEST_1

  • Request22 39 3C
  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Camshaft adjustment, exhaust bank 1, actual value CUPRA_CAM_ADJ_EXH_BANK_1_ACT

  • Request22 13 6C
  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 125)
Range
-262.144 to 262.136 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment, exhaust bank 1, specified value CUPRA_CAM_ADJ_EXH_BANK_1_SPEC

  • Request22 13 71
  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 125)
Range
-262.144 to 262.136 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment, exhaust bank 2, actual value CUPRA_CAM_ADJ_EXH_BANK_2_ACT

  • Request22 13 6D
  • Service 22DID 136D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment, exhaust bank 2, specified value CUPRA_CAM_ADJ_EXH_BANK_2_SPEC

  • Request22 13 72
  • Service 22DID 1372
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 125)
Range
-262 to 262 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment, exhaust, activation CUPRA_CAM_ADJ_EXH

  • Request22 12 7B
  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Camshaft adjustment, exhaust, actual value CUPRA_CAM_ADJ_EXH_ACT

  • Request22 20 1A
  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2020 to 2023, 2026. Not supported for 2024 to 2025.

Camshaft adjustment, exhaust, specified value CUPRA_CAM_ADJ_EXH_SPEC

  • Request22 20 19
  • Service 22DID 2019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment, intake bank 1, actual value CUPRA_CAM_ADJ_INT_BANK_1_ACT

  • Request22 13 6E
  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment, intake bank 1, specified value CUPRA_CAM_ADJ_INT_BANK_1_SPEC

  • Request22 13 73
  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 125)
Range
-262 to 262 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment, intake, actual value CUPRA_CAM_ADJ_INT_ACT

  • Request22 20 1E
  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2020 to 2026.

Camshaft adjustment, intake, specified value CUPRA_CAM_ADJ_INT_SPEC

  • Request22 20 1D
  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2020 to 2026.

Camshaft end position CUPRA_CAMS_END

  • Request22 13 41
  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2020 to 2026.

Camshaft position, deviation from the base position CUPRA_CAM_POS_DEV_BASE_POS

  • Request22 13 85
  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2020 to 2026.

Camshaft position, start of phase window CUPRA_CAM_POS_START_PHASE

  • Request22 10 07
  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2020 to 2026.

Camshaft start position CUPRA_PQ35_CAMS_START

  • Request22 10 07
  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Cat. converter oxygen storage capacity measured CUPRA_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED

  • Request22 15 07
  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Cat. converter oxygen storage capacity measured CUPRA_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED_V2

  • Request22 15 07
  • Service 22DID 1507
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Cat. temperature, bank 1 CUPRA_CAT_T_BANK_1

  • Request22 12 98
  • Service 22DID 1298
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 273.15)
Range
-273 to 3822 °C
Unit
°C

In testing for 2020 to 2026.

Cat. temperature, bank 2 CUPRA_CAT_T_BANK_2

  • Request22 12 99
  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 273.15)
Range
-273 to 3822 °C
Unit
°C

In testing for 2020 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2023. Supported for 2021, 2024 to 2026.

Catalyst temperature, calculated CUPRA_CAT_T_CALC

  • Request22 15 15
  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 − 50)
Range
-50 to 1225 °C
Unit
°C

In testing for 2020 to 2023, 2026. Not supported for 2024 to 2025.

Centrifugal oil temperature CUPRA_PQ35_CENTRIFUGAL_OIL_TConfirmed

  • Request22 38 B2
  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Example reply from a 2024 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x1E = 30 → 30

Formula
val
Range
-128 to 127
Unit
Number

Confirmed for 2021, 2024. In testing for 2020, 2022. Not supported for 2023, 2025 to 2026.

Chain elongation inlet, mileage at last adaptation CUPRA_CHAIN_ELONGATION_INLET

  • Request22 51 6C
  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Chain elongation outlet, mileage at last adaptation CUPRA_CHAIN_ELONGATION

  • Request22 51 49
  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 CUPRA_CHAIN_ELONGATION_NO_VALID_1

  • Request22 41 89
  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Chain elongation, no of valid initial values, intake bank 1 CUPRA_CHAIN_ELONGATION_NO_1

  • Request22 41 87
  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Clutch #1 maximum temperature CUPRA_PQ35_CLUTCH_1_MAXIMUM_TConfirmed

  • Request22 11 18
  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0155 = 341 → 341 °C

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2021. In testing for 2020, 2022. Not supported for 2023 to 2026.

Clutch #2 maximum temperature CUPRA_PQ35_CLUTCH_2_MAXIMUM_TConfirmed

  • Request22 11 18
  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

0x00EE = 238 → 238 °C

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2021. In testing for 2020, 2022. Not supported for 2023 to 2026.

Clutch 0 temperature calculated CUPRA_C7_CLUTCH_0_T_CALCULATED

  • Request22 12 0F
  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 600 °C
Unit
°C

In testing for 2020 to 2026.

Clutch 0 temperature calculated CUPRA_MQB_DL382_CLUTCH_0_T_CALCULATED

  • Request22 12 0F
  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 600 °C
Unit
°C

In testing for 2020, 2022, 2024. Not supported for 2021, 2023, 2025 to 2026.

Clutch 1 temperature CUPRA_CLUTCH_1_T

  • Request22 10 2B
  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2020 to 2026.

Clutch 1 temperature CUPRA_PQ35_CLUTCH_1_TConfirmed

  • Request22 10 2B
  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x1A = 26 → 26 °C

Formula
val
Range
0 to 255 °C
Unit
°C

Confirmed for 2021. In testing for 2020, 2022, 2024. Not supported for 2023, 2025 to 2026.

Clutch 1 temperature protection overheat protection 1 quantity CUPRA_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTYConfirmed

  • Request22 38 81
  • Service 22DID 3881
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2021. In testing for 2020, 2022, 2024. Not supported for 2023, 2025 to 2026.

Clutch 1 temperature protection warning 1 quantity CUPRA_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTYConfirmed

  • Request22 38 7F
  • Service 22DID 387F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Example reply from a 2024 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2021, 2024. In testing for 2020, 2022. Not supported for 2023, 2025 to 2026.

Clutch 1 temperature protection warning 2 quantity CUPRA_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTYConfirmed

  • Request22 38 80
  • Service 22DID 3880
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Example reply from a 2024 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2021, 2024. In testing for 2020, 2022. Not supported for 2023, 2025 to 2026.

Clutch 2 temperature CUPRA_CLUTCH_2_T

  • Request22 10 2C
  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2020 to 2026.

Clutch 2 temperature CUPRA_PQ35_CLUTCH_2_TConfirmed

  • Request22 10 2C
  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x1B = 27 → 27 °C

Formula
val
Range
0 to 255 °C
Unit
°C

Confirmed for 2021. In testing for 2020, 2022, 2024. Not supported for 2023, 2025 to 2026.

Clutch 2 temperature protection overheat protection 1 quantity CUPRA_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTYConfirmed

  • Request22 38 85
  • Service 22DID 3885
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Example reply from a 2024 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2021, 2024. In testing for 2020, 2022. Not supported for 2023, 2025 to 2026.

Clutch 2 temperature protection warning 1 quantity CUPRA_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTYConfirmed

  • Request22 38 83
  • Service 22DID 3883
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2021. In testing for 2020, 2022, 2024. Not supported for 2023, 2025 to 2026.

Clutch 2 temperature protection warning 2 quantity CUPRA_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTYConfirmed

  • Request22 38 84
  • Service 22DID 3884
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Example reply from a 2024 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2021, 2024. In testing for 2020, 2022. Not supported for 2023, 2025 to 2026.

Clutch center central plate temperature CUPRA_CLU_CENTER_CENTRAL_T

  • Request22 10 2A
  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Clutch temperature CUPRA_DIFF_CLUTCH_T

  • Request22 F1 05
  • Service 22DID F105
  • Module71E → 788
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 2 − 50)
Range
-50 to 460 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2023.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2023.

Commanded crankshaft torque CUPRA_CMD_CRANK_TQ

  • Request22 11 E0
  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2021, 2023 to 2026.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2021, 2024 to 2026.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2025 to 2026.

Compression test cylinder 1 CUPRA_COMPRESSION_TEST_CYL_1

  • Request22 11 29
  • Service 22DID 1129
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2020 to 2026.

Compression test cylinder 2 CUPRA_PQ35_COMP_TEST_CYL_2

  • Request22 11 2A
  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Compression test cylinder 3 CUPRA_PQ35_COMP_TEST_CYL_3

  • Request22 11 2B
  • Service 22DID 112B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Compression test cylinder 4 CUPRA_PQ35_COMP_TEST_CYL_4

  • Request22 11 2C
  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Compression test, cylinder 1 CUPRA_COMPRESSION_TEST_CYL_1_V2

  • Request22 29 9B
  • Service 22DID 299B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2020 to 2026.

Compression test, cylinder 2 CUPRA_COMPRESSION_TEST_CYL_2

  • Request22 29 9C
  • Service 22DID 299C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2020 to 2026.

Compression test, cylinder 3 CUPRA_COMPRESSION_TEST_CYL_3

  • Request22 29 9D
  • Service 22DID 299D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2020 to 2026.

Compression test, cylinder 4 CUPRA_COMPRESSION_TEST_CYL_4

  • Request22 29 9E
  • Service 22DID 299E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2020 to 2026.

Control module temperature CUPRA_CTRL_MODULE_T

  • Request22 03 01
  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Control module temperature CUPRA_CTRL_MODULE_T_V2

  • Request22 02 8D
  • Service 22DID 028D
  • Module71D → 787
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Control module temperature CUPRA_ECU_TEMP

  • Request22 02 8D
  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Control module temperature CUPRA_ECU_TEMP_K

  • Request22 02 8D
  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020 to 2026.

Control module temperature CUPRA_ECU_TEMP_KELVIN

  • Request22 02 8D
  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-40 to 150 °C
Unit
°C

In testing for 2020 to 2026.

Control module temperature CUPRA_MQB_TCM_ECU_TConfirmed

  • Request22 02 8D
  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x1C = 28 → 28 °C

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2021. In testing for 2020, 2022, 2024. Not supported for 2023, 2025 to 2026.

Converter loss torque CUPRA_TCM_CONVERTER_LOSS_TORQUE

  • Request22 10 10
  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2020 to 2026.

Coolant circulation pump duty CUPRA_COOLANT_CIRC_PUMP_DUTY

  • Request22 27 6D
  • Service 22DID 276D
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Coolant circulation pump, activation CUPRA_CLT_CIRCULATION_PMP_ACTIVATION

  • Request22 27 6D
  • Service 22DID 276D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant circulation pump, control CUPRA_CLT_CIRCULATION_PMP

  • Request22 16 7E
  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant fan 1 activation, $1117 CUPRA_CLT_FAN_1_ACTIVATION_1117

  • Request22 11 17
  • Service 22DID 1117
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Coolant fan 1 duty cycle CUPRA_COOL_FAN_1_DUTY

  • Request22 11 16
  • Service 22DID 1116
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant fan 1, activation CUPRA_CLT_FAN_1_ACTIVATION

  • Request22 20 55
  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant fan 1, activation CUPRA_COOLANT_FAN_1_ACTIVATION

  • Request22 11 30
  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Coolant fan 1, activation CUPRA_COOLANT_FAN_1_ACTIVATION_V2

  • Request22 11 30
  • Service 22DID 1130
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant fan 2 duty CUPRA_CLT_FAN_2_DUTY

  • Request22 11 14
  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Coolant fan 2 duty cycle CUPRA_PQ35_COOL_FAN_2_DUTY

  • Request22 11 14
  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Coolant fan 2, activation CUPRA_CLT_FAN_2_ACTIVATION

  • Request22 20 56
  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant fan activation, actual value CUPRA_CLT_FAN_ACTIVATION_ACT

  • Request22 26 06
  • Service 22DID 2606
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2020 to 2026.

Coolant fan activation, specified value CUPRA_CLT_FAN_ACTIVATION_SPEC

  • Request22 26 07
  • Service 22DID 2607
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2020 to 2026.

Coolant fan, requested by A/C CUPRA_CLT_FAN_REQ_AC

  • Request22 10 18
  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 1000000)
Range
-399.9989 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant shut-off valve, closed CUPRA_CLT_SHUT_OFF_VLV

  • Request22 26 82
  • Service 22DID 2682
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2020 to 2026.

Coolant temperature at engine outlet, calculated CUPRA_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED

  • Request22 44 90
  • Service 22DID 4490
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Coolant temperature at engine outlet, calculated CUPRA_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED_V2

  • Request22 44 90
  • Service 22DID 4490
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at engine outlet, calculated CUPRA_ECT_ENG_OUTLET_CALC

  • Request22 10 64
  • Service 22DID 1064
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at engine start CUPRA_COOLANT_T_AT_ENGINE_START

  • Request22 12 91
  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Coolant temperature at engine start CUPRA_COOLANT_T_AT_ENGINE_START_V2

  • Request22 12 91
  • Service 22DID 1291
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at engine start CUPRA_ECT_ENG_START

  • Request22 29 35
  • Service 22DID 2935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at radiator outlet CUPRA_COOLANT_T

  • Request22 11 35
  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Coolant temperature at radiator outlet CUPRA_EARLY_COOLANT_T

  • Request22 11 35
  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at radiator outlet CUPRA_ECT_RADIATOR_OUTLET

  • Request22 11 B5
  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at radiator outlet 2 CUPRA_ECT_RAD_OUT_2

  • Request22 10 9B
  • Service 22DID 109B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at radiator outlet v.1 CUPRA_ECT_RADIATOR_OUTLET_V_1

  • Request22 15 CD
  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at radiator outlet, actual value CUPRA_ECT_RADIATOR_OUTLET_ACT

  • Request22 20 2B
  • Service 22DID 202B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at radiator outlet, actual value CUPRA_ECT_RADIATOR_OUTLET_ACT_7E0

  • Request22 10 2C
  • Service 22DID 102C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at radiator outlet, specified value CUPRA_ECT_RADIATOR_OUTLET_SPEC

  • Request22 20 2C
  • Service 22DID 202C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature at radiator output, specified value CUPRA_COOLANT_T_AT_RADIATOR_OUTPUT_SPECIFIED_VALUE

  • Request22 11 35
  • Service 22DID 1135
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Coolant temperature difference between engine and radiator CUPRA_ECT_DIFF_ENG

  • Request22 20 2E
  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature linear CUPRA_ECT_LINEAR

  • Request22 15 13
  • Service 22DID 1513
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 29297 ÷ 10000000 − 48)
Range
-48 to 143.9978 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature modeled value CUPRA_COOLANT_T_MODELED_VALUE

  • Request22 13 A0
  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Coolant temperature modeled value CUPRA_COOLANT_T_MODELED_VALUE_V2

  • Request22 13 A0
  • Service 22DID 13A0
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature, maximum value CUPRA_ECT_MAX

  • Request22 15 11
  • Service 22DID 1511
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature, minimum value CUPRA_ECT_MIN

  • Request22 15 12
  • Service 22DID 1512
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2026.

Cooling fan 2 CUPRA_COOLING_FAN_2

  • Request22 11 2E
  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2020 to 2026.

Cooling inlet temperature CUPRA_BMS_COOL_IN_T

  • Request22 18 1C
  • Service 22DID 181C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Cooling outlet temperature CUPRA_BMS_COOL_OUT_T

  • Request22 18 1D
  • Service 22DID 181D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Correction factor of oil temperature for engine protection CUPRA_CORR_FACTOR_OIL_T

  • Request22 3F 4F
  • Service 22DID 3F4F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12207 ÷ 100000000)
Range
0 to 7.99
Unit
Number

In testing for 2020 to 2026.

Correction values for main pressure adaptation CUPRA_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT

  • Request22 11 A7
  • Service 22DID 11A7
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Coupling solenoid current CUPRA_CPL_SOL_I

  • Request22 18 00
  • Service 22DID 1800
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 6250000)
Range
-63.99 to 63.99 A
Unit
A

In testing for 2020 to 2026.

Crankshaft rotation angle when closing the quantity control valve CUPRA_CRANK_ROT_ANG

  • Request22 10 EB
  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2020 to 2026.

Critical engine oil level CUPRA_PQ35_OIL_LVL_CRIT

  • Request22 11 BD
  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 250)
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 0 CUPRA_CTR_MIS_DC_MMV_CYL_0

  • Request22 14 8D
  • Service 22DID 148D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 1 CUPRA_CTR_MIS_DC_MMV_CYL_1

  • Request22 14 8E
  • Service 22DID 148E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 2 CUPRA_CTR_MIS_DC_MMV_CYL_2

  • Request22 14 8F
  • Service 22DID 148F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Current N215 pressure control valve 1 CUPRA_CURRENT_N215_P_CTRL_1

  • Request22 10 24
  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2026.

Current N216 pressure control valve 2 CUPRA_CURRENT_N216_P_CTRL_2

  • Request22 10 26
  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2026.

Current N217 pressure control valve 3 CUPRA_CURRENT_N217_P_CTRL_3

  • Request22 10 28
  • Service 22DID 1028
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2026.

Current N218 pressure control valve 4 CUPRA_CURRENT_N218_P_CTRL_4

  • Request22 10 25
  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2026.

Current N233 pressure control valve 5 CUPRA_CURRENT_N233_P_CTRL_5

  • Request22 10 27
  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2026.

Current N443 pressure control valve 7 main pressure CUPRA_CURRENT_N443_P_CTRL_7_P

  • Request22 10 2A
  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2026.

Current solenoid CUPRA_CURRENT_SOLENOID

  • Request22 10 37
  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2020 to 2026.

Current type of driver counter CUPRA_CURRENT_TYPE_DRIVER

  • Request22 10 13
  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder 1 internal torque CUPRA_CYL_1_INTERNAL_TQ

  • Request22 58 47
  • Service 22DID 5847
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Cylinder 2 internal torque CUPRA_CYL_2_INTERNAL_TQ

  • Request22 58 49
  • Service 22DID 5849
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Cylinder 3 internal torque CUPRA_CYL_3_INTERNAL_TQ

  • Request22 58 4B
  • Service 22DID 584B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Cylinder 4 internal torque CUPRA_CYL_4_INTERNAL_TQ

  • Request22 58 4D
  • Service 22DID 584D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Cylinder block temperature sensor CUPRA_CYL_BLOCK_T_SENS

  • Request22 51 D4
  • Service 22DID 51D4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Cylinder head temperature CUPRA_CYL_HEAD_T

  • Request22 10 65
  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 460)
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2020 to 2026.

Cylinder head temperature, actual CUPRA_CYL_HEAD_T_ACT

  • Request22 10 65
  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Desired torque filtered CUPRA_DES_TQ_FILTERED

  • Request22 10 64
  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2026.

Desired torque raw CUPRA_DES_TQ_RAW

  • Request22 10 61
  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2026.

Diesel particulate filter air pressure sensor raw value CUPRA_DPF_AIR_P_SENS_RAW

  • Request22 44 94
  • Service 22DID 4494
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter ash load limit CUPRA_DPF_ASH_LOAD_LIM

  • Request22 40 6B
  • Service 22DID 406B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter cleaning deviation reaction time CUPRA_DPF_CLEANING_DEV

  • Request22 44 F5
  • Service 22DID 44F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.768 to 32.767
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter counter for regeneration time CUPRA_DPF_CNT_REGEN_TIME

  • Request22 39 F9
  • Service 22DID 39F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 100)
Range
0 to 42949672 s
Unit
s

In testing for 2020 to 2026.

Diesel particulate filter differential pressure CUPRA_DPF_DIFF_P

  • Request22 20 84
  • Service 22DID 2084
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter differential pressure offset CUPRA_PQ35_DPF_DIFF_P_OFFSET

  • Request22 10 F1
  • Service 22DID 10F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter differential pressure raw value, bank 1 CUPRA_DPF_DIFF_P_RAW_BANK_1

  • Request22 16 6B
  • Service 22DID 166B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter differential pressure raw value, bank 2 CUPRA_DPF_DIFF_P_RAW_BANK_2

  • Request22 16 6C
  • Service 22DID 166C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter differential pressure sensor temperature CUPRA_DPF_DIFF_P_SENS_T

  • Request22 43 C0
  • Service 22DID 43C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 19531 ÷ 1000000 − 50)
Range
-689.9918 to 589.9722 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter differential pressure variant 2 CUPRA_PQ35_DPF_DIFF_P_2

  • Request22 10 F3
  • Service 22DID 10F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter differential pressure, raw value 1 CUPRA_DPF_DIFF_P_RAW_1

  • Request22 43 BC
  • Service 22DID 43BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter differential pressure, raw value 2 CUPRA_DPF_DIFF_P_RAW_2

  • Request22 43 BF
  • Service 22DID 43BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter exhaust gas flow volume CUPRA_DPF_EXH_VOL

  • Request22 11 E6
  • Service 22DID 11E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter exhaust temperature CUPRA_DPF_EXH_T

  • Request22 44 F8
  • Service 22DID 44F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter field regeneration, cancel conditions CUPRA_DPF_FIELD_REGEN

  • Request22 29 F7
  • Service 22DID 29F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter field regeneration, lock status CUPRA_DPF_FIELD_REGEN_LOCK_V2

  • Request22 20 88
  • Service 22DID 2088
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter field regeneration, request status CUPRA_DPF_FIELD_REGEN_REQ

  • Request22 20 87
  • Service 22DID 2087
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter inlet temperature CUPRA_PQ35_DPF_IN_T

  • Request22 11 B2
  • Service 22DID 11B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter input gas temperature CUPRA_DPF_INPUT_GAS_T

  • Request22 29 7B
  • Service 22DID 297B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4 − 20)
Range
-20 to 1000 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter input gas temperature CUPRA_DPF_INPUT_GAS_T_7E0

  • Request22 44 9B
  • Service 22DID 449B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter input temperature raw value CUPRA_DPF_INPUT_T_RAW

  • Request22 44 9B
  • Service 22DID 449B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter offset for differential pressure CUPRA_DPF_OFFSET_DIFF_P

  • Request22 20 85
  • Service 22DID 2085
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter oil ash mass CUPRA_DPF_OIL_ASH_MASS

  • Request22 40 6C
  • Service 22DID 406C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter oil ash mass CUPRA_MQB_DPF_OIL_ASH_MASS

  • Request22 1A BD
  • Service 22DID 1ABD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0011921 ÷ 10000)
Range
0 to 512
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter oil ash volume CUPRA_DPF_OIL_ASH_VOLUME

  • Request22 20 8B
  • Service 22DID 208B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 L
Unit
L

In testing for 2020 to 2026.

Diesel particulate filter oil ash volume, bank 1 CUPRA_DPF_OIL_ASH_VOLUME_1

  • Request22 14 B9
  • Service 22DID 14B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 L
Unit
L

In testing for 2020 to 2026.

Diesel particulate filter oil ash volume, bank 2 CUPRA_DPF_OIL_ASH_VOLUME_2

  • Request22 14 5F
  • Service 22DID 145F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 L
Unit
L

In testing for 2020 to 2026.

Diesel particulate filter outlet temperature CUPRA_EARLY_DPF_OUT_T

  • Request22 10 F9
  • Service 22DID 10F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 1200 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter outlet temperature CUPRA_PQ35_DPF_OUT_T

  • Request22 10 F9
  • Service 22DID 10F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter output gas temperature CUPRA_DPF_OUTPUT_GAS_T

  • Request22 29 7D
  • Service 22DID 297D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4 − 20)
Range
-20 to 1000 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter output temperature raw value CUPRA_DPF_OUTPUT_T_RAW

  • Request22 44 9A
  • Service 22DID 449A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter regeneration cancel conditions CUPRA_DPF_REGEN_CANCEL

  • Request22 13 7C
  • Service 22DID 137C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter regeneration level current CUPRA_DPF_REGEN_LEVEL

  • Request22 08 0D
  • Service 22DID 080D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter regeneration request status CUPRA_DPF_REGEN_REQ_STAT

  • Request22 20 87
  • Service 22DID 2087
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter regeneration status CUPRA_DPF_REGEN_STAT

  • Request22 08 09
  • Service 22DID 0809
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter soot mass calculated, bank 1 CUPRA_DPF_SOOT_MASS_CALC_1

  • Request22 14 BA
  • Service 22DID 14BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter soot mass calculated, bank 2 CUPRA_DPF_SOOT_MASS_CALC_2

  • Request22 14 5E
  • Service 22DID 145E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter soot mass measured, bank 1 CUPRA_DPF_SOOT_MASS_MEAS_1

  • Request22 14 BB
  • Service 22DID 14BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter soot mass measured, bank 2 CUPRA_DPF_SOOT_MASS_MEAS_2

  • Request22 14 5D
  • Service 22DID 145D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter soot measured CUPRA_DPF_SOOT_MEAS

  • Request22 20 8C
  • Service 22DID 208C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter soot volume in exhaust, mg/m^3 CUPRA_DPF_SOOT_VOLUME_EXH_M_3

  • Request22 18 C0
  • Service 22DID 18C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter statistics current avg. temperature after DPF CUPRA_DPF_STATISTICS_T

  • Request22 15 7C
  • Service 22DID 157C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter statistics current avg. temperature after part.filter CUPRA_DPF_STATISTICS_CURRENT_AVG_T

  • Request22 40 01
  • Service 22DID 4001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter statistics current calculated charging rate, g/km CUPRA_DPF_STATISTICS_CURRENT_G

  • Request22 40 07
  • Service 22DID 4007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 100000000)
Range
-3.99 to 3.99
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter statistics current measured charging rate, g/km CUPRA_DPF_STATISTICS_G

  • Request22 40 05
  • Service 22DID 4005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 100000000)
Range
-3.99 to 3.99
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter statistics, regeneration time CUPRA_DPF_STATISTICS_REGEN

  • Request22 40 1F
  • Service 22DID 401F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 64)
Range
0 to 16320 s
Unit
s

In testing for 2020 to 2026.

Diesel particulate filter surface gas temperature CUPRA_DPF_SURFACE_GAS_T

  • Request22 3D 7F
  • Service 22DID 3D7F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter surface temperature CUPRA_DPF_SFC_T

  • Request22 10 44
  • Service 22DID 1044
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter surface temperature CUPRA_DPF_SURFACE_T

  • Request22 44 FB
  • Service 22DID 44FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16 − 273.15)
Range
-2321.15 to 1774.7875 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter surface temperature CUPRA_PQ35_DPF_SURF_T

  • Request22 10 44
  • Service 22DID 1044
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter time since last regeneration CUPRA_DPF_TIME_SINCE_REGEN

  • Request22 20 89
  • Service 22DID 2089
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 3600)
Range
0 to 1193046 h
Unit
h

In testing for 2020 to 2026.

Diesel particulate filter time since last regeneration, h, bank 1 CUPRA_DPF_TIME_SINCE_REGEN_H_1

  • Request22 14 34
  • Service 22DID 1434
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 3600)
Range
0 to 1193046
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter time since last regeneration, h, bank 2 CUPRA_DPF_TIME_SINCE_REGEN_H_2

  • Request22 14 64
  • Service 22DID 1464
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 3600)
Range
0 to 1193046
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter, differential pressure sensor, adapted value CUPRA_DPF_DIFF_P_SENS_ADAPTED

  • Request22 44 B2
  • Service 22DID 44B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter, differential pressure sensor, dynamic offset CUPRA_DPF_DIFF_P_SENS

  • Request22 44 A3
  • Service 22DID 44A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2020 to 2026.

Diesel particulate filter, service regeneration while driving CUPRA_DPF_SERVICE_REGEN_WHILE

  • Request22 29 10
  • Service 22DID 2910
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter, service regeneration, current duration CUPRA_DPF_SERVICE_REGEN

  • Request22 20 7D
  • Service 22DID 207D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2020 to 2026.

Differential pressure CUPRA_DIFF_P

  • Request22 14 F5
  • Service 22DID 14F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Direct injections counter CUPRA_DIRECT_INJECTIONS

  • Request22 42 67
  • Service 22DID 4267
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2020 to 2026.

Drive motor current CUPRA_MOTOR_I

  • Request22 14 7D
  • Service 22DID 147D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1024 to 1023.968 A
Unit
A

In testing for 2020 to 2026.

Drive motor effective current CUPRA_MOTOR_I_RMS

  • Request22 46 65
  • Service 22DID 4665
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.937 A
Unit
A

In testing for 2020 to 2026.

Drive motor phase u current CUPRA_MOTOR_U_I

  • Request22 3E F9
  • Service 22DID 3EF9
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 A
Unit
A

In testing for 2020 to 2026.

Drive motor phase u current, unlimited CUPRA_MOTOR_U_I_RAW

  • Request22 46 71
  • Service 22DID 4671
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 A
Unit
A

In testing for 2020 to 2026.

Drive motor phase v current CUPRA_MOTOR_V_I

  • Request22 3E FA
  • Service 22DID 3EFA
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 A
Unit
A

In testing for 2020 to 2026.

Drive motor phase v current, unlimited CUPRA_MOTOR_V_I_RAW

  • Request22 46 70
  • Service 22DID 4670
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 A
Unit
A

In testing for 2020 to 2026.

Drive motor phase w current CUPRA_MOTOR_W_I

  • Request22 3E FB
  • Service 22DID 3EFB
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 A
Unit
A

In testing for 2020 to 2026.

Drive motor phase w current, unlimited CUPRA_MOTOR_W_I_RAW

  • Request22 46 6F
  • Service 22DID 466F
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 A
Unit
A

In testing for 2020 to 2026.

Drive motor power CUPRA_MOTOR_PWR

  • Request22 14 7E
  • Service 22DID 147E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 250)
Range
-131.072 to 131.068 kW
Unit
kW

In testing for 2020 to 2026.

Drive motor power, actual CUPRA_MOTOR_PWR_PE

  • Request22 46 56
  • Service 22DID 4656
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.984 kW
Unit
kW

In testing for 2020 to 2026.

Drive motor power, calculated CUPRA_MOTOR_PWR_CALC

  • Request22 46 58
  • Service 22DID 4658
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.984 kW
Unit
kW

In testing for 2020 to 2026.

Drive motor speed CUPRA_MOTOR_RPM_ECM

  • Request22 14 9A
  • Service 22DID 149A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2020 to 2026.

Drive motor speed 2 CUPRA_MOTOR_RPM_2

  • Request22 3E EC
  • Service 22DID 3EEC
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2020 to 2026.

Drive motor speed, actual CUPRA_MOTOR_RPM_V2

Pelican can show this parameter as the engine speed.

  • Request22 3E 97
  • Service 22DID 3E97
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2020 to 2026.

Drive motor speed, measured CUPRA_MOTOR_RPM_ACT

  • Request22 46 59
  • Service 22DID 4659
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2020 to 2026.

Drive motor speed, standard CUPRA_MOTOR_RPM_SAE

  • Request22 F4 0C
  • Service 22DID F40C
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2020 to 2026.

Drive motor stator temperature CUPRA_MOTOR_STATOR_T

  • Request22 46 72
  • Service 22DID 4672
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor temperature CUPRA_MOTOR_T_V2

  • Request22 3E 94
  • Service 22DID 3E94
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor torque CUPRA_MOTOR_TQ

  • Request22 14 7F
  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 3)
Range
-10922.666 to 10922.333 N·m
Unit
N·m

In testing for 2020 to 2026.

Drive motor torque, actual CUPRA_MOTOR_TQ_PE

  • Request22 3E E9
  • Service 22DID 3EE9
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 N·m
Unit
N·m

In testing for 2020 to 2026.

Drive motor torque, calculated CUPRA_MOTOR_TQ_CALC

  • Request22 03 08
  • Service 22DID 0308
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 N·m
Unit
N·m

In testing for 2020 to 2026.

Drive motor voltage CUPRA_MOTOR_V

  • Request22 14 84
  • Service 22DID 1484
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.968 V
Unit
V

In testing for 2020 to 2026.

Driver demand torque CUPRA_TCM_DRIVER_DEMAND_TORQUE

  • Request22 10 0B
  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2020 to 2026.

Driving mode sensor, hall sensor a CUPRA_DRIVING_MODE_SENS

  • Request22 21 0D
  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Driving position CUPRA_DRIVING_POS

  • Request22 21 0E
  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Driving resistance index CUPRA_DRIVING_RES_INDEX

  • Request22 21 08
  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127
Unit
Number

In testing for 2020 to 2026.

Dynamic average of ignition angle delay adjustment CUPRA_DYNAMIC_AVG_IGN_ANG

  • Request22 29 4A
  • Service 22DID 294A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °
Unit
°

In testing for 2020 to 2026.

Dynamic torque limitation CUPRA_DYNAMIC_TQ_LIM

  • Request22 10 67
  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2026.

Ea888b boost pressure control, adaptation value 0 CUPRA_EA888B_BOOST_P_CTRL_0

  • Request22 11 FF
  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 281 ÷ 100)
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2020 to 2026.

Ea888b boost pressure control, adaptation value 1 CUPRA_EA888B_BOOST_P_CTRL_1

  • Request22 12 00
  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 281 ÷ 100)
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2020 to 2026.

Ea888b boost pressure control, adaptation value 2 CUPRA_EA888B_BOOST_P_CTRL_2

  • Request22 12 01
  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 281 ÷ 100)
Range
-359 to 356
Unit
Raw value

In testing for 2020 to 2026.

Ea888b boost pressure control, adaptation value 3 CUPRA_EA888B_BOOST_P_CTRL_3

  • Request22 12 02
  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 281 ÷ 100)
Range
-359 to 356
Unit
Raw value

In testing for 2020 to 2026.

Ea888b boost pressure regulator, commanded CUPRA_EA888B_BOOST_P_CMD

  • Request22 11 A3
  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Early ignition counter for toque reduction, cylinder 1 CUPRA_EARLY_IGN_CNT_TOQUE_1

  • Request22 4E 4A
  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter for toque reduction, cylinder 2 CUPRA_EARLY_IGN_CNT_TOQUE_2

  • Request22 4E 4A
  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter for toque reduction, cylinder 3 CUPRA_EARLY_IGN_CNT_TOQUE_3

  • Request22 4E 4A
  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter for toque reduction, cylinder 4 CUPRA_EARLY_IGN_CNT_TOQUE_4

  • Request22 4E 4A
  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder 1 CUPRA_EARLY_IGN_CNT_CYL_1

  • Request22 17 22
  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder 2 CUPRA_EARLY_IGN_CNT_CYL_2

  • Request22 17 25
  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder 3 CUPRA_EARLY_IGN_CNT_CYL_3

  • Request22 17 23
  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder 4 CUPRA_EARLY_IGN_CNT_CYL_4

  • Request22 17 24
  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 1 CUPRA_EARLY_IGN_CNT_CYL_SUPPRESS_1

  • Request22 4E 49
  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 2 CUPRA_EARLY_IGN_CNT_CYL_SUPPRESS_2

  • Request22 4E 49
  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 3 CUPRA_EARLY_IGN_CNT_CYL_SUPPRESS_3

  • Request22 4E 49
  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 4 CUPRA_EARLY_IGN_CNT_CYL_SUPPRESS_4

  • Request22 4E 49
  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 1 CUPRA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1

  • Request22 4E 4B
  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 2 CUPRA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2

  • Request22 4E 4B
  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 3 CUPRA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3

  • Request22 4E 4B
  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 4 CUPRA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4

  • Request22 4E 4B
  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, total, cylinder 1 CUPRA_EARLY_IGN_CNT_TOT_1

  • Request22 17 15
  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, total, cylinder 2 CUPRA_EARLY_IGN_CNT_TOT_2

  • Request22 17 18
  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, total, cylinder 3 CUPRA_EARLY_IGN_CNT_TOT_3

  • Request22 17 16
  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Early ignition counter, total, cylinder 4 CUPRA_EARLY_IGN_CNT_TOT_4

  • Request22 17 17
  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Effective injection duration CUPRA_EFFECTIVE_INJ_DUR

  • Request22 15 E7
  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2020 to 2026.

EGT after catalyst, model bank 1 CUPRA_EGT_AFTER_CAT_MODEL_1

  • Request22 2A E9
  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.023438 − 273.15)
Range
-273 to 1262 °C
Unit
°C

In testing for 2020 to 2026.

EGT after catalyst, model bank b CUPRA_EGT_AFTER_CAT_MODEL_B

  • Request22 2A E3
  • Service 22DID 2AE3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.023438 − 273.15)
Range
-273 to 1262 °C
Unit
°C

In testing for 2020 to 2026.

Elector motor 1 torque CUPRA_EM_TORQ_1

  • Request22 11 53
  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every10.25 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Elector motor 2 torque CUPRA_EM_TORQ_2

  • Request22 11 54
  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Elector motor 3 torque CUPRA_EM_TORQ_3

  • Request22 11 55
  • Service 22DID 1155
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Electric additional coolant pump control, high circle CUPRA_ELEC_ADDITIONAL_CLT

  • Request22 14 88
  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 1000000)
Range
-399.9989 to 100 %
Unit
%

In testing for 2020 to 2026.

Electric motor 1 rpm CUPRA_EM_RPM_1

  • Request22 11 51
  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-100 to 100 rpm
Unit
rpm

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Electric motor 2 rpm CUPRA_EM_RPM_2

  • Request22 11 52
  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-100 to 100 rpm
Unit
rpm

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Electric motor non-vehicle power limitation CUPRA_EM_NV_PWR_LIM

  • Request22 15 D1
  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 W
Unit
W

In testing for 2020 to 2026.

Electric motor power limitation CUPRA_EM_PWR_LIM

  • Request22 15 D1
  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 50)
Range
0 to 3276750 W
Unit
W

In testing for 2020 to 2026.

Electric motor RPM CUPRA_ENG_MOTOR_RPM

  • Request22 3D F8
  • Service 22DID 3DF8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Electronic differential lock active CUPRA_ELEC_DIFF_ACT

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Electronic differential lock front left brake temperature CUPRA_ELEC_DIFF_FL_BRK_T

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-20 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Electronic differential lock front right brake temperature CUPRA_ELEC_DIFF_FR_BRK_T

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-20 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Electronic differential lock rear left brake temperature CUPRA_ELEC_DIFF_RL_BRK_T

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-20 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Electronic differential lock rear right brake temperature CUPRA_ELEC_DIFF_RR_BRK_T

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-20 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Energy balance of last driving cycle CUPRA_ENERGY_BALANCE_LAST

  • Request22 2A 15
  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 Ah
Unit
Ah

In testing for 2020 to 2026.

Energy content CUPRA_ENERGY_CONTENT

  • Request22 22 E4
  • Service 22DID 22E4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 kWh
Unit
kWh

In testing for 2020 to 2026.

Engine air mass, specified value CUPRA_ENG_AIR_MASS_SPEC

  • Request22 20 37
  • Service 22DID 2037
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2020 to 2026.

Engine compartment temperature raw value CUPRA_ENG_COMPARTMENT_T

  • Request22 46 B1
  • Service 22DID 46B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2020 to 2026.

Engine control module temperature CUPRA_ENG_CTRL_MODULE_T

  • Request22 02 8D
  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023 to 2026. Supported for 2020.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2025.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2025.

Engine drag torque CUPRA_ENG_DRAG_TQ

  • Request22 20 9C
  • Service 22DID 209C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Request01 8E
  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2023.

Engine oil level CUPRA_ENG_OIL_LEVEL_7E0

  • Request22 15 04
  • Service 22DID 1504
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

In testing for 2020 to 2026.

Engine oil level CUPRA_ENG_OIL_LEVEL_7E0_2

  • Request22 11 BC
  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 250)
Range
-131 to 131 mm
Unit
mm

In testing for 2020 to 2026.

Engine oil level CUPRA_PQ35_OIL_LVL

  • Request22 11 BC
  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 250)
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Engine oil level current value CUPRA_ENG_OIL_LEVEL

  • Request22 58 D1
  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine oil pressure CUPRA_EOP

  • Request22 15 03
  • Service 22DID 1503
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 416)
Range
0 to 157 psi
Unit
psi

In testing for 2020 to 2026.

Engine oil sump temperature CUPRA_ENG_OIL_SUMP_T

  • Request22 15 B7
  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 460)
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2020 to 2026.

Engine oil temperature CUPRA_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 E6
  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 60)
Range
-60 to 195 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Engine oil temperature CUPRA_EOT_714

  • Request22 20 2F
  • Service 22DID 202F
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 58)
Range
0 to 197
Unit
Number

In testing for 2020 to 2026.

Engine oil temperature CUPRA_EOT_7E0

  • Request22 11 02
  • Service 22DID 1102
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature CUPRA_EOT_7E0_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 20 2F
  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature CUPRA_EOT_FC00

Pelican can show this parameter as the engine oil temperature.

  • Request22 11 BD
  • Service 22DID 11BD
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature CUPRA_EOT_V2Confirmed

Scaling is unknown, needs further validation.

  • Request22 11 BE
  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2021. In testing for 2022. Not supported for 2020, 2023 to 2026.

Engine oil temperature CUPRA_EOT_V3

  • Request22 20 2F
  • Service 22DID 202F
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 58)
Range
0 to 255
Unit
Number

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Engine oil temperature CUPRA_EOT_V4

  • Request22 20 2F
  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature 2 CUPRA_PQ35_ENGINE_OIL_T_2

Pelican can show this parameter as the engine oil temperature.

  • Request22 17 9C
  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Engine oil temperature measured value CUPRA_EOT_MEAS

Pelican can show this parameter as the engine oil temperature.

  • Request22 16 32
  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature sensor 2 CUPRA_EOT_SENS_2

Pelican can show this parameter as the engine oil temperature.

  • Request22 40 D5
  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature, calculated CUPRA_EOT_CALC

  • Request22 20 1A
  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2020 to 2023, 2026. Not supported for 2024 to 2025.

Engine oil temperature, engine control module CUPRA_EOT_ECM

  • Request22 11 BD
  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-40 to 200 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature, pulse sensor CUPRA_EOT_PULS

  • Request22 17 9E
  • Service 22DID 179E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature, variant 4 CUPRA_EOT_VAR_4

  • Request22 40 D5
  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Engine outlet coolant temperature calculated CUPRA_ENG_OUTLET_ECT_CALC

  • Request22 10 63
  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020 to 2026.

Engine protection, torque limit CUPRA_ENG_PROTECTION_TQ

  • Request22 2B C0
  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine radiator fan request CUPRA_ENG_RADIATOR_FAN_REQ

  • Request22 10 0B
  • Service 22DID 100B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Request01 63
  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2023. Supported for 2025.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2021, 2023, 2025. Supported for 2020, 2024, 2026.

Engine start quantity CUPRA_PQ35_ENG_START_QTY

  • Request22 10 69
  • Service 22DID 1069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Engine temperature control actuator CUPRA_ENG_T_CTRL_ACTUATOR

  • Request22 3D 73
  • Service 22DID 3D73
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine temperature management actuator, after-run stop CUPRA_ENG_T_MANAGEMENT_ACTUATOR_AFTER

  • Request22 44 1D
  • Service 22DID 441D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Engine temperature management actuator, duty cycle activation CUPRA_ENG_T_MANAGEMENT_ACTUATOR

  • Request22 44 1A
  • Service 22DID 441A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine temperature management actuator, raw value CUPRA_ENG_T_MANAGEMENT

  • Request22 44 19
  • Service 22DID 4419
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Engine temperature management actuator, specified value CUPRA_ENG_T_MANAGEMENT_SPEC

  • Request22 3F E4
  • Service 22DID 3FE4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 1000000)
Range
-399.9989 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine temperature management actuator, stop open CUPRA_ENG_T_MANAGEMENT_ACTUATOR_STOP

  • Request22 44 1C
  • Service 22DID 441C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Engine torque CUPRA_ENG_TORQUE

  • Request22 15 5A
  • Service 22DID 155A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1024 to 1023.968 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque CUPRA_ENG_TQ

  • Request22 20 02
  • Service 22DID 2002
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 49 ÷ 625)
Range
0 to 5137
Unit
Number

In testing for 2020 to 2026.

Engine torque CUPRA_ENG_TQ_7E0

  • Request22 10 47
  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque CUPRA_ENG_TQ_7E0_V2

  • Request22 43 7C
  • Service 22DID 437C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque CUPRA_ENG_TQ_7E1

  • Request22 70 64
  • Service 22DID 7064
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque CUPRA_ENG_TQ_7E1_V2

  • Request22 20 02
  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2020 to 2023, 2026. Not supported for 2024 to 2025.

Engine torque CUPRA_ENG_TQ_V3

  • Request22 20 02
  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque CUPRA_ENGINE_TORQUE

  • Request22 10 10
  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Engine torque CUPRA_ENGINE_TORQUE_V2

  • Request22 10 10
  • Service 22DID 1010
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque CUPRA_PQ35_ENG_TORQUE

  • Request22 15 5A
  • Service 22DID 155A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1024 to 1023.96875 N·m
Unit
N·m

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Engine torque CUPRA_PQ35_ENG_TRQ

  • Request22 10 47
  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Engine torque CUPRA_TCM_ENGINE_TORQUE

  • Request22 10 0C
  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque limitation CUPRA_ENG_TQ_LIM

  • Request22 10 8F
  • Service 22DID 108F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque limitation CUPRA_TCM_ENGINE_TORQUE_LIMITATION

  • Request22 10 0E
  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine torque loss CUPRA_TCM_ENGINE_TORQUE_LOSS

  • Request22 10 0F
  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2020 to 2026.

Environment data camshaft input 1 CUPRA_ENVD_CAM_IN_1

  • Request22 12 13
  • Service 22DID 1213
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Evaporator temperature CUPRA_EVAPORATOR_T

  • Request22 42 BB
  • Service 22DID 42BB
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Excessive temperature protection CUPRA_EXCESSIVE_T

  • Request22 21 17
  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Exhaust camshaft, adaptation bias CUPRA_EXH_CAM_ADPT_BIAS

  • Request22 17 4A
  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2020 to 2026.

Exhaust camshaft, adaptation sensor tolerance CUPRA_EXH_CAM_ADPT_SENS

  • Request22 17 55
  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2020 to 2026.

Exhaust gas jet volume in particle filter CUPRA_EXH_GAS_JET_VOLUME

  • Request22 3D 7E
  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100)
Range
-3276800 to 3276700 L
Unit
L

In testing for 2020 to 2026.

Exhaust gas jet volume in particle filter, m^3/h CUPRA_EXH_GAS_JET_VOLUME_M_3_H

  • Request22 3D 7E
  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364
Unit
Number

In testing for 2020 to 2026.

Exhaust gas recirculation valve 2 bank 1 mass flow CUPRA_MQB_EGR_VALVE_2_B1_FLOW

  • Request22 13 13
  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Exhaust gas recirculation valve duty CUPRA_PQ35_EGR_DUTY

  • Request22 10 C2
  • Service 22DID 10C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Exhaust gas temperature CUPRA_EXH_GAS_T

  • Request22 F4 3C
  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature - calculated after catalyst CUPRA_EXH_GAS_T_CALC_AFTER

  • Request22 2A E9
  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 293 ÷ 12500 − 273.15)
Range
-273.15 to 1262.9904 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature at probe before the front catalytic converter, model value CUPRA_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE

  • Request22 13 9C
  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Exhaust gas temperature at the probe before the front catalytic converter, model value CUPRA_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE_V2

  • Request22 13 9C
  • Service 22DID 139C
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature before catalyst CUPRA_EXHAUST_GAS_T_BEFORE_CATALYST

  • Request22 12 82
  • Service 22DID 1282
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50 − 193.93)
Range
-193.93 to 1116.77 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Exhaust gas temperature before catalyst, modeled CUPRA_EGT_PRE_CAT_MODELED

  • Request22 14 21
  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature before catalytic converter CUPRA_EXH_GAS_T_BEFORE

  • Request22 29 6F
  • Service 22DID 296F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature before gasoline particulate filter CUPRA_EXH_GAS_T_BEFORE_GPF

  • Request22 08 2D
  • Service 22DID 082D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature sensor 1 CUPRA_EXH_GAS_T_SENS_1

  • Request22 16 6F
  • Service 22DID 166F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature sensor 1 CUPRA_EXH_GAS_T_SENS_1_V2

  • Request22 29 76
  • Service 22DID 2976
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature sensor 1 CUPRA_PQ35_EXH_GAS_T_1

  • Request22 10 FB
  • Service 22DID 10FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Exhaust gas temperature sensor 1, bank 2 CUPRA_EXH_GAS_T_SENS_1_2

  • Request22 16 70
  • Service 22DID 1670
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature sensor 2 CUPRA_PQ35_EXHAUST_GAS_T_SENSOR_2

  • Request22 14 F7
  • Service 22DID 14F7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Exhaust gas temperature sensor 3 CUPRA_EXH_GAS_T_SENS_3

  • Request22 14 BE
  • Service 22DID 14BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature sensor 3 CUPRA_EXH_GAS_T_SENS_3_V2

  • Request22 11 B2
  • Service 22DID 11B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature sensor 3, bank 2 CUPRA_EXH_GAS_T_SENS_3_2

  • Request22 15 6F
  • Service 22DID 156F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature sensor 4 CUPRA_EXH_GAS_T_SENS_4

  • Request22 16 6D
  • Service 22DID 166D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature, sensor 4, bank 2 CUPRA_EXH_GAS_T_S4_B2

  • Request22 16 6E
  • Service 22DID 166E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust phase deviation, actual value CUPRA_EXH_PHASE_DEV_ACT

  • Request22 41 85
  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2020 to 2026.

Exhaust phase deviation, after chain replacement CUPRA_EXH_PHASE_DEV_AFTER

  • Request22 41 7D
  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2020 to 2026.

Exhaust phase deviation, after repair CUPRA_EXH_PHASE_DEV_AFTER_REPAIR

  • Request22 41 81
  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2020 to 2026.

Exhaust temperature before the catalyst, modeled CUPRA_EXH_T_BEFORE_CAT

  • Request22 14 21
  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust temperature control downstream oxidation catalyst filtered model error CUPRA_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR

  • Request22 1A D7
  • Service 22DID 1AD7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Exhaust timing chain extension, mileage since last adaptation CUPRA_EXH_TIM_CHAIN

  • Request22 51 49
  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2020 to 2026.

Field limit CUPRA_FIELD_LIM

  • Request22 11 F6
  • Service 22DID 11F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655
Unit
Raw value

In testing for 2020 to 2026.

Field limit value CUPRA_PQ35_FIELD_LIM

  • Request22 11 F6
  • Service 22DID 11F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

First pilot injection, duration CUPRA_PRE_INJ_1_DUR

  • Request22 14 D0
  • Service 22DID 14D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2500)
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2020 to 2026.

First pilot injection, start CUPRA_PRE_INJ_1_START

  • Request22 14 C7
  • Service 22DID 14C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Friction torque CUPRA_FRICTION_TQ

  • Request22 10 65
  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2026.

Front defrost flap air outlet temperature CUPRA_FRONT_DEFROST_FLAP_T

  • Request22 42 C8
  • Service 22DID 42C8
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Front left deflector temperature CUPRA_CLIMATE_FR_L_DEFL_T

  • Request22 26 0C
  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 3)
Range
0 to 84.915 °C
Unit
°C

In testing for 2020 to 2026.

Front left temperature flap actual CUPRA_FRONT_LEFT_T_FLAP_ACT

  • Request22 26 22
  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 0.5)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Front left temperature flap actual value CUPRA_CLIMATE_FR_L_T_FLP_ACT_VALUEConfirmed

  • Request22 26 22
  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 16 to 23 of the reply, 8 bits.

0xA3 = 163 → (163 ÷ 2) = 81.5 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Front right deflector temperature CUPRA_CLIMATE_FR_R_DEFL_T

  • Request22 26 0D
  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 3)
Range
0 to 84.915 °C
Unit
°C

In testing for 2020 to 2026.

Front right temperature flap actual CUPRA_FRONT_RIGHT_T_FLAP_ACT

  • Request22 26 26
  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 0.5)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Front right temperature flap actual value CUPRA_CLIMATE_FR_R_T_FLP_ACT_VALUEConfirmed

  • Request22 26 26
  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 16 to 23 of the reply, 8 bits.

0x9F = 159 → (159 ÷ 2) = 79.5 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Fuel metering valve position CUPRA_FUEL_METER

  • Request22 11 48
  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 23
  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2023.

Fuel temperature CUPRA_FUEL_T_7E0

  • Request22 16 2D
  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-40 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Fuel temperature CUPRA_PQ35_FUEL_T

  • Request22 16 2D
  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Gasoline particulate filter blockage rate calculated CUPRA_GPF_BLOCKAGE_RATE_CALC

  • Request22 2A FB
  • Service 22DID 2AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1280)
Range
0 to 51.1992
Unit
Number

In testing for 2020 to 2026.

Gasoline particulate filter blockage rate threshold calculated CUPRA_GPF_BLOCKAGE_RATE

  • Request22 2A F9
  • Service 22DID 2AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1280)
Range
0 to 51.1992
Unit
Number

In testing for 2020 to 2026.

Gasoline particulate filter blockage ratio calculated absolute CUPRA_GPF_BLOCKAGE_RAT

  • Request22 08 27
  • Service 22DID 0827
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100
Unit
Number

In testing for 2020 to 2026.

Gasoline particulate filter blockage ratio calculated relative CUPRA_GPF_BLOCKAGE_RAT_CALC_REL

  • Request22 08 28
  • Service 22DID 0828
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100
Unit
Number

In testing for 2020 to 2026.

Gasoline particulate filter high level moisture build-up CUPRA_GPF_HIGH_LEVEL

  • Request22 24 B2
  • Service 22DID 24B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107
Unit
Raw value

In testing for 2020 to 2026.

Gasoline particulate filter high level of soot build-up CUPRA_GPF_HIGH_LEVEL_SOOT

  • Request22 24 B3
  • Service 22DID 24B3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2020 to 2026.

Gasoline particulate filter loading stage CUPRA_GPF_LOADING_STAGE

  • Request22 08 2B
  • Service 22DID 082B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Gasoline particulate filter maximum ash build-up reached CUPRA_GPF_MAX_ASH_BUILD_UP

  • Request22 24 B5
  • Service 22DID 24B5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510
Unit
Raw value

In testing for 2020 to 2026.

Gasoline particulate filter maximum soot build-up reached CUPRA_GPF_MAX_SOOT_BUILD

  • Request22 24 B4
  • Service 22DID 24B4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2020 to 2026.

Gasoline particulate filter oil ash load calculated CUPRA_GPF_OIL_ASH_LOAD

  • Request22 08 04
  • Service 22DID 0804
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Gasoline particulate filter oil ash mass CUPRA_GPF_OIL_ASH_MASS

  • Request22 40 6C
  • Service 22DID 406C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2020 to 2026.

Gasoline particulate filter soot load calculated CUPRA_GPF_SOOT_LOAD_CALC

  • Request22 08 29
  • Service 22DID 0829
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Gasoline particulate filter soot mass calculated CUPRA_GPF_SOOT_MASS_CALC

  • Request22 20 8B
  • Service 22DID 208B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2020 to 2026.

Gasoline particulate filter water load CUPRA_GPF_WATER_LOAD

  • Request22 08 02
  • Service 22DID 0802
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Gasoline particulate filter water mass CUPRA_GPF_WATER_MASS

  • Request22 21 39
  • Service 22DID 2139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107
Unit
Raw value

In testing for 2020 to 2026.

Generator current CUPRA_GEN_CURRENT

  • Request22 2A 1C
  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 + 9)
Range
0 to 6562.5 A
Unit
A

In testing for 2020 to 2026.

Generator load CUPRA_GEN_LOAD

  • Request22 10 5C
  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Generator load normalized value CUPRA_GENERATOR_LOAD_NORMALIZED_VALUE

  • Request22 15 CA
  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Generator load normalized value CUPRA_GENERATOR_LOAD_NORMALIZED_VALUE_V2

  • Request22 15 CA
  • Service 22DID 15CA
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Generator load signal CUPRA_GEN_LOAD_SIG

  • Request22 10 33
  • Service 22DID 1033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Generator load signal CUPRA_GEN_LOAD_SIG_V3

  • Request22 20 50
  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Generator load signal CUPRA_GENERATOR_LOAD_SIG

  • Request22 10 1C
  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Generator load signal CUPRA_GENERATOR_LOAD_SIG_V2

  • Request22 10 1C
  • Service 22DID 101C
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Generator performance CUPRA_GENERATOR_PERFORMANCE

  • Request22 10 97
  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 94248 ÷ 10000)
Range
-308831.8464 to 308822.421 W
Unit
W

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Generator performance CUPRA_GENERATOR_PERFORMANCE_V2

  • Request22 10 97
  • Service 22DID 1097
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 94248 ÷ 10000)
Range
-308831.8464 to 308822.4216 W
Unit
W

In testing for 2020 to 2026.

Generator torque request CUPRA_GENERATOR_TORQUE_REQUEST

  • Request22 10 1B
  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Generator torque request CUPRA_GENERATOR_TORQUE_REQUEST_V2

  • Request22 10 1B
  • Service 22DID 101B
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Heater circulation pump, nominal value CUPRA_HEATER_CIRCULATION

  • Request22 16 7F
  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Heater support pump, specified value CUPRA_HEATER_SUPPORT_PMP_SPEC

  • Request22 43 36
  • Service 22DID 4336
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Height correction CUPRA_HEIGHT_CORR

  • Request22 11 36
  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0000610348)
Range
0 to 3.9999
Unit
Number

In testing for 2020 to 2026.

High pressure control, adaptation CUPRA_HIGH_P_CTRL_ADPT

  • Request22 11 D2
  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2000)
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2020 to 2026.

High pressure EGR actuator, activation CUPRA_HIGH_P_EGR_ACTUATOR

  • Request22 13 34
  • Service 22DID 1334
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

High pressure regulation, adaptation value CUPRA_HIGH_P_REGULATION

  • Request22 43 84
  • Service 22DID 4384
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

High-pressure exhaust gas recirculation closing, variant 1 CUPRA_HIGH_P_EGR_CLOSING_1

  • Request22 F4 69
  • Service 22DID F469
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × -25 ÷ 64 + 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

High-pressure exhaust gas recirculation closing, variant 2 CUPRA_HIGH_P_EGR_CLOSING_2

  • Request22 F4 2C
  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × -25 ÷ 64 + 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Hill descent control CUPRA_HDC_ACTIVE

  • Request22 18 08
  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Hill descent control, incline CUPRA_HDC_INCLINE

  • Request22 18 08
  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Humidity sensor, relative humidity CUPRA_HUMIDITY_SENS_REL

  • Request22 50 36
  • Service 22DID 5036
  • Module70E → 778
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 99 ÷ 200)
Range
0 to 32439 %
Unit
%

In testing for 2020 to 2026.

Hybrid temperature CUPRA_HYBRID_T

  • Request22 11 96
  • Service 22DID 1196
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2020 to 2026.

ID of current driving program CUPRA_ID_CURRENT_DRIVING

  • Request22 10 12
  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

IGA_CYL_KNK, 0 CUPRA_IGA_CYL_KNK_0

  • Request22 13 F2
  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.625 °
Unit
°

In testing for 2020 to 2026.

IGA_CYL_KNK, 1 CUPRA_IGA_CYL_KNK_1

  • Request22 13 F3
  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.625 °
Unit
°

In testing for 2020 to 2026.

IGA_CYL_KNK, 2 CUPRA_IGA_CYL_KNK_2

  • Request22 13 F4
  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.625 °
Unit
°

In testing for 2020 to 2026.

IGA_CYL_KNK, 3 CUPRA_IGA_CYL_KNK_3

  • Request22 13 F5
  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.625 °
Unit
°

In testing for 2020 to 2026.

IGA_IGC, 0 CUPRA_IGA_IGC_0

  • Request22 13 8A
  • Service 22DID 138A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1499 ÷ 4000 − 35.625)
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2020 to 2026.

IGA_IGC, 1 CUPRA_IGA_IGC_1

  • Request22 13 8B
  • Service 22DID 138B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1499 ÷ 4000 − 35.625)
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2020 to 2026.

IGA_IGC, 2 CUPRA_IGA_IGC_2

  • Request22 13 8C
  • Service 22DID 138C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1499 ÷ 4000 − 35.625)
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2020 to 2026.

IGA_IGC, 3 CUPRA_IGA_IGC_3

  • Request22 13 8D
  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1499 ÷ 4000 − 35.625)
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2020 to 2026.

Ignition angle current cylinder, actual value CUPRA_IGN_ANG_CURRENT_CYL_ACT

  • Request22 20 04
  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-25 to 25 °
Unit
°

In testing for 2020 to 2026.

Ignition timing angle retard, cylinder 1 CUPRA_IGNITION_TIMING_ANGLE_RETARD_C1

  • Request22 10 E2
  • Service 22DID 10E2
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 75 ÷ 100)
Range
-24576 to 24575.25 °
Unit
°

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Ignition timing angle retard, cylinder 2 CUPRA_IGNITION_TIMING_ANGLE_RETARD_C2

  • Request22 10 E3
  • Service 22DID 10E3
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 75 ÷ 100)
Range
-24576 to 24575.25 °
Unit
°

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Ignition timing angle retard, cylinder 3 CUPRA_IGNITION_TIMING_ANGLE_RETARD_C3

  • Request22 10 E4
  • Service 22DID 10E4
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 75 ÷ 100)
Range
-24576 to 24575.25 °
Unit
°

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Ignition timing angle retard, cylinder 4 CUPRA_IGNITION_TIMING_ANGLE_RETARD_C4

  • Request22 10 E5
  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 75 ÷ 100)
Range
-24576 to 24575.25 °
Unit
°

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Ignition timing angle retard, cylinder 4 CUPRA_IGNITION_TIMING_ANGLE_RETARD_C4_V2

  • Request22 10 E5
  • Service 22DID 10E5
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 75 ÷ 100)
Range
-24576 to 24575.25 °
Unit
°

In testing for 2020 to 2026.

Injection amount deviation cylinder 1 CUPRA_INJ_AMOUNT_DEV_CYL_1

  • Request22 20 46
  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.00036623)
Range
-12 to 12
Unit
Raw value

In testing for 2020 to 2026.

Injection amount deviation cylinder 1 CUPRA_PQ35_INJ_DEV_CYL_1

  • Request22 10 FF
  • Service 22DID 10FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injection amount deviation cylinder 2 CUPRA_INJ_AMOUNT_DEV_CYL_2

  • Request22 20 47
  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.00036623)
Range
-12 to 12
Unit
Raw value

In testing for 2020 to 2026.

Injection amount deviation cylinder 2 CUPRA_PQ35_INJ_DEV_CYL_2

  • Request22 11 05
  • Service 22DID 1105
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injection amount deviation cylinder 3 CUPRA_INJ_AMOUNT_DEV_CYL_3

  • Request22 20 48
  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.00036623)
Range
-12 to 12
Unit
Raw value

In testing for 2020 to 2026.

Injection amount deviation cylinder 3 CUPRA_PQ35_INJ_DEV_CYL_3

  • Request22 11 00
  • Service 22DID 1100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injection amount deviation cylinder 4 CUPRA_INJ_AMOUNT_DEV_CYL_4

  • Request22 20 49
  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.00036623)
Range
-12 to 12
Unit
Raw value

In testing for 2020 to 2026.

Injection amount deviation cylinder 4 CUPRA_PQ35_INJ_DEV_CYL_4

  • Request22 11 04
  • Service 22DID 1104
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injection quantity deviation cylinder 1 CUPRA_INJ_QTY_DEV_CYL_1

  • Request22 10 FF
  • Service 22DID 10FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation cylinder 2 CUPRA_INJ_QTY_DEV_CYL_2

  • Request22 11 06
  • Service 22DID 1106
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation cylinder 3 CUPRA_INJ_QTY_DEV_CYL_3

  • Request22 11 04
  • Service 22DID 1104
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation cylinder 4 CUPRA_INJ_QTY_DEV_CYL_4

  • Request22 11 00
  • Service 22DID 1100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation cylinder 5 CUPRA_INJ_QTY_DEV_CYL_5

  • Request22 11 07
  • Service 22DID 1107
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation cylinder 6 CUPRA_INJ_QTY_DEV_CYL_6

  • Request22 11 05
  • Service 22DID 1105
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation, cylinder 1 CUPRA_INJ_QTY_DEV_CYL_1_V2

  • Request22 20 46
  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation, cylinder 2 CUPRA_INJ_QTY_DEV_CYL_2_V2

  • Request22 20 4A
  • Service 22DID 204A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation, cylinder 3 CUPRA_INJ_QTY_DEV_CYL_3_V2

  • Request22 20 48
  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation, cylinder 4 CUPRA_INJ_QTY_DEV_CYL_4_V2

  • Request22 20 47
  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation, cylinder 5 CUPRA_INJ_QTY_DEV_CYL_5_V2

  • Request22 20 4B
  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injection quantity deviation, cylinder 6 CUPRA_INJ_QTY_DEV_CYL_6_V2

  • Request22 20 49
  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Injector 1 rail pressure calibration point 1 CUPRA_PQ35_INJ_1_RAIL_P_1

  • Request22 10 D0
  • Service 22DID 10D0
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 1 rail pressure calibration point 2 CUPRA_INJ_1_RAIL_P_2

  • Request22 10 D6
  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 1 rail pressure calibration point 2 CUPRA_PQ35_INJ_1_RAIL_P_2

  • Request22 10 D6
  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.05 ÷ 1000)
Range
-1.6384 to 1.63835 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 1 rail pressure calibration point 3 CUPRA_PQ35_INJ_1_RAIL_P_3

  • Request22 10 DC
  • Service 22DID 10DC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 2 rail pressure calibration point 1 CUPRA_INJ_2_RAIL_P_1

  • Request22 10 D3
  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 2 rail pressure calibration point 1 CUPRA_PQ35_INJ_2_RAIL_P_1

  • Request22 10 D3
  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.05 ÷ 1000)
Range
-1.6384 to 1.63835 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 2 rail pressure calibration point 2 CUPRA_PQ35_INJ_2_RAIL_P_2

  • Request22 10 D9
  • Service 22DID 10D9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 2 rail pressure calibration point 3 CUPRA_PQ35_INJ_2_RAIL_P_3

  • Request22 10 DF
  • Service 22DID 10DF
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 2, rail pressure calibration point 1 CUPRA_INJ_2_RAIL_P_1_V2

  • Request22 10 D4
  • Service 22DID 10D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 2, rail pressure calibration point 2 CUPRA_INJ_2_RAIL_P_2

  • Request22 10 DA
  • Service 22DID 10DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 2: rail pressure calibration point 1 CUPRA_INJ_2_RAIL_P_CAL_PT_1_146E

  • Request22 14 6E
  • Service 22DID 146E
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Injector 2: rail pressure calibration point 2 CUPRA_INJ_2_RAIL_P_CAL_PT_2_1474

  • Request22 14 74
  • Service 22DID 1474
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Injector 2: rail pressure calibration point 3 CUPRA_INJ_2_RAIL_P_CAL_PT_3_147A

  • Request22 14 7A
  • Service 22DID 147A
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Injector 3 rail pressure calibration point 1 CUPRA_INJ_3_RAIL_P_1

  • Request22 10 D1
  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 3 rail pressure calibration point 1 CUPRA_PQ35_INJ_3_RAIL_P_1

  • Request22 10 D1
  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.05 ÷ 1000)
Range
-1.6384 to 1.63835 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 3 rail pressure calibration point 2 CUPRA_PQ35_INJ_3_RAIL_P_2

  • Request22 10 D2
  • Service 22DID 10D2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 3 rail pressure calibration point 3 CUPRA_PQ35_INJ_3_RAIL_P_3

  • Request22 10 DD
  • Service 22DID 10DD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 4 rail pressure calibration point 2 CUPRA_PQ35_INJ_4_RAIL_P_2

  • Request22 10 D8
  • Service 22DID 10D8
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 4 rail pressure calibration point 3 CUPRA_INJ_4_RAIL_P_3

  • Request22 10 DE
  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 4 rail pressure calibration point 3 CUPRA_PQ35_INJ_4_RAIL_P_3

  • Request22 10 DE
  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.05 ÷ 1000)
Range
-1.6384 to 1.63835 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Injector 4, rail pressure calibration point 2 CUPRA_INJ_4_RAIL_P_2

  • Request22 10 D7
  • Service 22DID 10D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 5, rail pressure calibration point 1 CUPRA_INJ_5_RAIL_P_1

  • Request22 10 D5
  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 5, rail pressure calibration point 2 CUPRA_INJ_5_RAIL_P_2

  • Request22 10 DB
  • Service 22DID 10DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 5, rail pressure calibration point 3 CUPRA_INJ_5_RAIL_P_3

  • Request22 10 E1
  • Service 22DID 10E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2020 to 2026.

Injector 7: rail pressure calibration point 1 CUPRA_INJ_7_RAIL_P_CAL_PT_1

  • Request22 14 6D
  • Service 22DID 146D
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Injector 7: rail pressure calibration point 2 CUPRA_INJ_7_RAIL_P_CAL_PT_2

  • Request22 14 73
  • Service 22DID 1473
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Injector 7: rail pressure calibration point 3 CUPRA_INJ_7_RAIL_P_CAL_PT_3

  • Request22 14 79
  • Service 22DID 1479
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Inlet flaps - actual value CUPRA_INLET_FLAPS_ACT

  • Request22 11 9D
  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Inlet flaps - requested value CUPRA_INLET_FLAPS_REQ

  • Request22 11 A0
  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Inside temperature CUPRA_INSIDE_T

  • Request22 26 13
  • Service 22DID 2613
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 50)
Range
-50 to 6503 °C
Unit
°C

In testing for 2020 to 2026.

Intake air temperature CUPRA_IAT_7E0

  • Request22 10 01
  • Service 22DID 1001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2020 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2024 to 2026.

Intake air temperature before throttle valve, raw value CUPRA_IAT_BEFORE_THROTTLE

  • Request22 15 C1
  • Service 22DID 15C1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2026.

Intake air temperature in intake manifold CUPRA_INTAKE_AIR_T_IN_INTAKE_MANIFOLD

  • Request22 14 9E
  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Intake air temperature in intake manifold CUPRA_INTAKE_AIR_T_IN_INTAKE_MANIFOLD_V2

  • Request22 14 9E
  • Service 22DID 149E
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2026.

Intake air temperature in intake manifold raw value CUPRA_IAT_INT_MANIFOLD_RAW

  • Request22 15 C0
  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2020 to 2026.

Intake air temperature raw value CUPRA_IAT_RAW

  • Request22 15 C0
  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020 to 2026.

Intake camshaft adaptation unit 1 phase length CUPRA_PQ35_CAMS_ADAPT_PHASE_1

  • Request22 12 FE
  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft signal edge position adapted edge 2 CUPRA_CAMS_EDGE_POS_2

  • Request22 11 89
  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2020 to 2026.

Intake camshaft signal edge position adapted edge 2 CUPRA_PQ35_CAMS_EDGE_POS_2

  • Request22 11 89
  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.9375 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft signal edge position adapted edge 3 CUPRA_CAMS_EDGE_POS_3

  • Request22 11 8A
  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2020 to 2026.

Intake camshaft signal edge position adapted edge 3 CUPRA_PQ35_CAMS_EDGE_POS_3

  • Request22 11 8A
  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.9375 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft signal edge position adapted edge 4 CUPRA_PQ35_CAMS_EDGE_POS_4

  • Request22 11 8B
  • Service 22DID 118B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft signal edge position adapted edge 5 CUPRA_PQ35_CAMS_EDGE_POS_5

  • Request22 11 8C
  • Service 22DID 118C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft signal edge position adapted edge 6 CUPRA_PQ35_CAMS_EDGE_POS_6

  • Request22 11 8D
  • Service 22DID 118D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft signal edge position adapted edge 7 CUPRA_PQ35_CAMS_EDGE_POS_7

  • Request22 11 8E
  • Service 22DID 118E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft signal edge position adapted edge 8 CUPRA_PQ35_CAMS_EDGE_POS_8

  • Request22 11 8F
  • Service 22DID 118F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft signal edge position adapted value edge 1 CUPRA_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1

  • Request22 17 3A
  • Service 22DID 173A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake camshaft, adaptation bias CUPRA_INT_CAM_ADPT_BIAS

  • Request22 17 4B
  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2020 to 2026.

Intake camshaft, adaptation sensor tolerance CUPRA_INT_CAM_ADPT_SENS

  • Request22 17 40
  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2020 to 2026.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023. Supported for 2021, 2024 to 2026.

Intake manifold pressure calculated CUPRA_MQB_INT_MAN_P

  • Request22 10 3C
  • Service 22DID 103C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Intake manifold pressure raw value CUPRA_INT_MANIFOLD_P_RAW

  • Request22 11 DC
  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 781.25 ÷ 10000)
Range
0 to 19.92
Unit
Raw value

In testing for 2020 to 2026.

Intake manifold pressure raw value CUPRA_INT_MANIFOLD_P_RAW_V2

  • Request22 3E 70
  • Service 22DID 3E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 bar
Unit
bar

In testing for 2020 to 2026.

Intake manifold pressure, commanded CUPRA_INT_MANIFOLD_P_CMD

  • Request22 11 DD
  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119.9218
Unit
Raw value

In testing for 2020 to 2026.

Intake manifold pressure, corrected CUPRA_INT_MANIFOLD_P

  • Request22 11 DA
  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119.9218
Unit
Raw value

In testing for 2020 to 2026.

Intake manifold runner control, acknowledgment CUPRA_INT_MANIFOLD_RUNNER_CTRL

  • Request22 20 6A
  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Intake manifold runner control, activation CUPRA_INT_MANIFOLD_RUNNER

  • Request22 20 69
  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Intake model air mass flow filtered value CUPRA_INT_MODEL_AIR_MASS

  • Request22 11 AB
  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Intake phase deviation, actual value CUPRA_INT_PHASE_DEV_ACT

  • Request22 18 00
  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2020 to 2026.

Intake phase deviation, after chain replacement CUPRA_INT_PHASE_DEV_AFTER

  • Request22 41 7B
  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2020 to 2026.

Intake phase deviation, after repair CUPRA_INT_PHASE_DEV_AFTER_REPAIR

  • Request22 41 7F
  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2020 to 2026.

Intake timing chain extension, mileage since last adaptation CUPRA_INT_TIM_CHAIN

  • Request22 51 6C
  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2020 to 2026.

Integrated mass of air since engine start CUPRA_INTEGRATED_MASS_AIR

  • Request22 11 75
  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8889 ÷ 25000)
Range
0 to 23301.6246
Unit
Raw value

In testing for 2020 to 2026.

Integrated mass of air since the first engine start CUPRA_INTEGRATED_MASS_AIR_SINCE

  • Request22 17 43
  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8889 ÷ 25000)
Range
0 to 23301.6246
Unit
Raw value

In testing for 2020 to 2026.

Intercooler air output temperature CUPRA_INTERCOOLER_AIR_T

  • Request22 16 28
  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Intercooler air output temperature CUPRA_PQ35_INTERCOOLER_AIR_OUTPUT_T

  • Request22 16 28
  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Kick down CUPRA_MQB_TCM_KICK_DOWNConfirmed

  • Request22 21 14
  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Example reply from a 2024 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021, 2024. In testing for 2020, 2022. Not supported for 2023, 2025 to 2026.

Kilometers driven since last event on K1 CUPRA_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1

  • Request22 11 5A
  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 10)
Range
0 to 7000 km
Unit
km

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Kilometers driven since last event on K2 CUPRA_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2

  • Request22 11 5C
  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 10)
Range
0 to 7000 km
Unit
km

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Knock retard 2 CUPRA_KNOCK_RETARD_2

  • Request22 10 E6
  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard 5 CUPRA_KNOCK_RETARD_5

  • Request22 10 E7
  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2020 to 2026.

Knock retard:, cylinder 1 CUPRA_KNOCK_RETARD_CYL_1

  • Request22 13 F2
  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2020 to 2026.

Knock retard:, cylinder 2 CUPRA_KNOCK_RETARD_CYL_2

  • Request22 13 F3
  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2020 to 2026.

Knock retard:, cylinder 3 CUPRA_KNOCK_RETARD_CYL_3

  • Request22 13 F4
  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2020 to 2026.

Knock retard:, cylinder 4 CUPRA_KNOCK_RETARD_CYL_4

  • Request22 13 F5
  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2020 to 2026.

Knock retard:, cylinder 5 CUPRA_KNOCK_RETARD_CYL_5

  • Request22 13 F6
  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2020 to 2026.

Knock retard:, cylinder 6 CUPRA_KNOCK_RETARD_CYL_6

  • Request22 13 F7
  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2020 to 2026.

Knock sensor 1 test CUPRA_KNOCK_SENS_1_TEST

  • Request22 39 3C
  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Knock sensor 2 test CUPRA_KNOCK_SENS_2_TEST

  • Request22 39 3C
  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Knock sensor 3 test CUPRA_KNOCK_SENS_3_TEST

  • Request22 39 3C
  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Knock sensor 4 test CUPRA_KNOCK_SENS_4_TEST

  • Request22 39 3C
  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Knock sensor, cylinder 1 CUPRA_KNOCK_SENS_CYL_1_V2

  • Request22 39 60
  • Service 22DID 3960
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

Knock sensor, cylinder 1 CUPRA_KNOCK_SNS_C1_V_MS

  • Request22 12 0E
  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0076294 ÷ 10000)
Range
0 to 3276
Unit
Number

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Knock sensor, cylinder 1 CUPRA_KNOCK_SNS_C1_V_MS_V2

  • Request22 12 0E
  • Service 22DID 120E
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0076294 ÷ 10000)
Range
0 to 3276
Unit
Number

In testing for 2020 to 2026.

Knock sensor, cylinder 2 CUPRA_KNOCK_SENS_CYL_2

  • Request22 12 12
  • Service 22DID 1212
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 7.62e-7)
Range
0 to 3272
Unit
Number

In testing for 2020 to 2026.

Knock sensor, cylinder 2 CUPRA_KNOCK_SENS_CYL_2_V3

  • Request22 39 61
  • Service 22DID 3961
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

Knock sensor, cylinder 2 CUPRA_KNOCK_SNS_C2_V_MS

  • Request22 12 11
  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0076294 ÷ 10000)
Range
0 to 3276
Unit
Number

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Knock sensor, cylinder 2 CUPRA_KNOCK_SNS_C2_V_MS_V2

  • Request22 12 11
  • Service 22DID 1211
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0076294 ÷ 10000)
Range
0 to 3276
Unit
Number

In testing for 2020 to 2026.

Knock sensor, cylinder 3 CUPRA_KNOCK_SENS_CYL_3_V3

  • Request22 39 62
  • Service 22DID 3962
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

Knock sensor, cylinder 3 CUPRA_KNOCK_SNS_C3_V_MS

  • Request22 12 0F
  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0076294 ÷ 10000)
Range
0 to 3276
Unit
Number

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Knock sensor, cylinder 3 CUPRA_KNOCK_SNS_C3_V_MS_V2

  • Request22 12 0F
  • Service 22DID 120F
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0076294 ÷ 10000)
Range
0 to 3276
Unit
Number

In testing for 2020 to 2026.

Knock sensor, cylinder 4 CUPRA_KNOCK_SENS_CYL_4_V3

  • Request22 39 63
  • Service 22DID 3963
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

Knock sensor, cylinder 4 CUPRA_KNOCK_SNS_C4_V_MS

  • Request22 12 10
  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0076294 ÷ 10000)
Range
0 to 3276
Unit
Number

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Knock sensor, cylinder 4 CUPRA_KNOCK_SNS_C4_V_MS_V2

  • Request22 12 10
  • Service 22DID 1210
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0076294 ÷ 10000)
Range
0 to 3276
Unit
Number

In testing for 2020 to 2026.

Lambda output value CUPRA_LAMBDA_OUTPUT

  • Request22 15 D4
  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 199997 ÷ 6553500000)
Range
0 to 1.99
Unit
Number

In testing for 2020 to 2026.

Lambda value at DPF inlet CUPRA_LAMBDA_DPF_INLET

  • Request22 08 0E
  • Service 22DID 080E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.768 to 32.767
Unit
Number

In testing for 2020 to 2026.

Lambda, actual value CUPRA_LAMBDA_ACT

  • Request22 10 D5
  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 50000000)
Range
-7.9999 to 7.9997
Unit
Number

In testing for 2020 to 2026.

Launch control counter CUPRA_LAUNCH_CTRL_CNT

  • Request22 38 F1
  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Launch control counter, variant 1 CUPRA_LAUNCH_CTRL_CNT_VAR_1

  • Request22 12 00
  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Left central air outlet temperature CUPRA_LEFT_CENTRAL_AIR_T

  • Request22 42 C5
  • Service 22DID 42C5
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Left footwell air outlet temperature CUPRA_LEFT_FOOTWELL_AIR_T

  • Request22 42 BC
  • Service 22DID 42BC
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Left rear footwell air outlet temperature CUPRA_LEFT_REAR_FOOTWELL_T

  • Request22 42 C1
  • Service 22DID 42C1
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Left rear upper air outlet temperature CUPRA_LEFT_REAR_HI_AIR_T

  • Request22 42 BE
  • Service 22DID 42BE
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Left side air outlet temperature CUPRA_LEFT_SIDE_AIR_OUTLET_T

  • Request22 42 C3
  • Service 22DID 42C3
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Leg deflector temperature CUPRA_CLIMATE_LEG_DEFL_T

  • Request22 26 11
  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 3)
Range
0 to 84.915 °C
Unit
°C

In testing for 2020 to 2026.

Limitation, smoke CUPRA_LIM_SMOKE

  • Request22 13 01
  • Service 22DID 1301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Limitation, torque CUPRA_LIM_TQ

  • Request22 10 6B
  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2023. Supported for 2021, 2024 to 2026.

Long term fuel trim at idle - direct injection CUPRA_LONG_TERM_FUEL_TRIM_IDLE_V2

  • Request22 17 7E
  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 3 ÷ 64)
Range
-1536 to 1535 %
Unit
%

In testing for 2020 to 2026.

Long term fuel trim at idle - port injection CUPRA_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Request22 17 80
  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 3 ÷ 64)
Range
-1536 to 1535 %
Unit
%

In testing for 2020 to 2026.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Request01 56
  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2023. Supported for 2025 to 2026.

Long term throttle adaptation to MAF sensor CUPRA_LONG_TERM_THROTTLE

  • Request22 11 3A
  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0000610351)
Range
0 to 3.99 %
Unit
%

In testing for 2020 to 2026.

Long-term adaptation of intake manifold injection CUPRA_LONG_TERM_ADPT_INT

  • Request22 41 4E
  • Service 22DID 414E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Long-term adaptation of intake manifold injection at idle CUPRA_LONG_TERM_ADPT_INT_MANIFOLD_INJ

  • Request22 41 4F
  • Service 22DID 414F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Lost torque adaptation A/C + driving mode CUPRA_LOST_TQ_ADPT_AC

  • Request22 43 7F
  • Service 22DID 437F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Lost torque adaptation driving mode CUPRA_LOST_TQ_ADPT_DRIVING

  • Request22 43 7E
  • Service 22DID 437E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Low press. EGR closing CUPRA_LOW_PRESS_EGR

  • Request22 13 14
  • Service 22DID 1314
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 2048)
Range
0 to 799 %
Unit
%

In testing for 2020 to 2026.

Low press. EGR closing CUPRA_LOW_PRESS_EGR_V2

  • Request22 40 6B
  • Service 22DID 406B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Low pressure EGR closing CUPRA_LOW_P_EGR_CLOSING

  • Request22 17 F4
  • Service 22DID 17F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × -25 ÷ 2048 + 100)
Range
-699 to 100 %
Unit
%

In testing for 2020 to 2026.

Lower adapted coupling point K2 from micro-slip path adaptation CUPRA_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT

  • Request22 11 0A
  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5)
Range
0 to 1275 mA
Unit
mA

In testing for 2020 to 2026.

M009, desired solenoid out 10 CUPRA_M009_DES_SOLENOID_10

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

M009, desired solenoid out 11 CUPRA_M009_DES_SOLENOID_11

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

M009, desired solenoid out 12 CUPRA_M009_DES_SOLENOID_12

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

M009, desired solenoid out 13 CUPRA_M009_DES_SOLENOID_13

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

M009, desired solenoid out 14 CUPRA_M009_DES_SOLENOID_14

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Main cat oxygen storage capacity age correction factor CUPRA_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR

  • Request22 14 F9
  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Main catalytic converter oxygen storage capacity age correction factor CUPRA_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR_V2

  • Request22 14 F9
  • Service 22DID 14F9
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2020 to 2026.

Main injection duration CUPRA_PQ35_MAIN_INJ_DURATION

  • Request22 14 CF
  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Main injection start position CUPRA_PQ35_MAIN_INJ_START

  • Request22 11 F2
  • Service 22DID 11F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Main injection, duration CUPRA_MAIN_INJ_DUR

  • Request22 14 CF
  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2500)
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2020 to 2026.

Main injection, start CUPRA_MAIN_INJ_START

  • Request22 11 F2
  • Service 22DID 11F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Manifold absolute pressure, raw value CUPRA_MAP_RAW

  • Request22 11 DC
  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119.9218
Unit
Raw value

In testing for 2020 to 2026.

Manual engine starts counter CUPRA_MANUAL_ENG_STARTS

  • Request22 29 98
  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Mass air flow over throttle valve CUPRA_MAF_OVER_THROTTLE

  • Request22 39 4F
  • Service 22DID 394F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2020 to 2026.

Mass air flow through throttle CUPRA_MAF_THROUGH_THROTTLE

  • Request22 11 AC
  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Mass air flow, commanded CUPRA_MAF_CMD

  • Request22 11 AD
  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Mass airflow sensor 1 bank 1 raw value CUPRA_MAF_1_B1_RAW

  • Request22 10 26
  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2020 to 2026.

Mass flow through throttle valve CUPRA_MASS_FLOW_THROUGH

  • Request22 11 0A
  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 2020 to 2026.

Max permissible engine torque CUPRA_MAX_PERMISSIBLE_ENG

  • Request22 21 1A
  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2026.

Maximum ECU temperature CUPRA_MAX_ECU_T

  • Request22 46 49
  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020 to 2026.

Maximum filling correction factor from knock control CUPRA_MAX_FILLING_CORR

  • Request22 10 E9
  • Service 22DID 10E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 3 ÷ 100000)
Range
0 to 1.96
Unit
Number

In testing for 2020 to 2026.

Maximum oil level for the service interval CUPRA_MAX_OIL_LEVEL

  • Request22 12 30
  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

In testing for 2020 to 2026.

Mean engine air mass CUPRA_MEAN_ENG_AIR_MASS

  • Request22 20 32
  • Service 22DID 2032
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2020 to 2026.

Mean engine air mass CUPRA_PQ35_MEAN_AIR_MASS

  • Request22 13 14
  • Service 22DID 1314
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.968
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Mean injection quantity CUPRA_MEAN_INJ_QTY

  • Request22 20 97
  • Service 22DID 2097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2020 to 2026.

Mean injection quantity CUPRA_MEAN_INJ_QUANTITY

  • Request22 11 39
  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Median injection timing CUPRA_MEDIAN_INJ_TIM

  • Request22 12 8C
  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2020 to 2026.

Mileage with ECU installed CUPRA_MILEAGE_ECU

  • Request22 10 A2
  • Service 22DID 10A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

In testing for 2020 to 2026.

Minimum oil level for the service interval CUPRA_MIN_OIL_LEVEL

  • Request22 12 31
  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

In testing for 2020 to 2026.

Misfires / 1000 revolutions, cylinder 1 CUPRA_MISFIRES_1000REV_C1

  • Request22 11 47
  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Misfires / 1000 revolutions, cylinder 2 CUPRA_MISFIRES_1000REV_C2

  • Request22 11 4A
  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Misfires / 1000 revolutions, cylinder 3 CUPRA_PQ35_FUEL_METER

  • Request22 11 48
  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Misfires / 1000 revolutions, cylinder 4 CUPRA_PQ35_BOOST_P_CMD

  • Request22 11 49
  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Misfires counter:, cylinder 1 CUPRA_MIS_CNT_1

  • Request22 14 7E
  • Service 22DID 147E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires counter:, cylinder 2 CUPRA_MIS_CNT_2

  • Request22 14 82
  • Service 22DID 1482
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires counter:, cylinder 3 CUPRA_MIS_CNT_3

  • Request22 14 80
  • Service 22DID 1480
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires counter:, cylinder 4 CUPRA_MIS_CNT_4

  • Request22 14 7F
  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires counter:, cylinder 5 CUPRA_MIS_CNT_5

  • Request22 14 83
  • Service 22DID 1483
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires counter:, cylinder 6 CUPRA_MIS_CNT_6

  • Request22 14 81
  • Service 22DID 1481
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires for 1000 revolutions, cylinder 1 CUPRA_MIS_1000_REVOLUTIONS_1

  • Request22 29 1D
  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires for 1000 revolutions, cylinder 2 CUPRA_MIS_1000_REVOLUTIONS_2

  • Request22 11 4B
  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires for 1000 revolutions, cylinder 2 CUPRA_MIS_1000_REVOLUTIONS_2_V2

  • Request22 29 20
  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires for 1000 revolutions, cylinder 3 CUPRA_MIS_1000_REVOLUTIONS_3

  • Request22 29 1E
  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires for 1000 revolutions, cylinder 4 CUPRA_MIS_1000_REVOLUTIONS_4

  • Request22 29 1F
  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires for 1000 revolutions, cylinder 5 CUPRA_MIS_1000_REVOLUTIONS_5

  • Request22 11 4C
  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires per 1000 revolutions, cylinder 1, port injection CUPRA_MIS_PER_1000_1

  • Request22 42 6B
  • Service 22DID 426B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires per 1000 revolutions, cylinder 2 CUPRA_MIS_PER_1000_2

  • Request22 10 F6
  • Service 22DID 10F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires per 1000 revolutions, cylinder 2, port injection CUPRA_MIS_PER_1000_2_V2

  • Request22 42 6C
  • Service 22DID 426C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires per 1000 revolutions, cylinder 3 CUPRA_MIS_PER_1000_3

  • Request22 10 F4
  • Service 22DID 10F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires per 1000 revolutions, cylinder 3, port injection CUPRA_MIS_PER_1000_3_V2

  • Request22 42 6D
  • Service 22DID 426D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires per 1000 revolutions, cylinder 4, port injection CUPRA_MIS_PER_1000_4

  • Request22 42 6E
  • Service 22DID 426E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires total CUPRA_MIS_TOT

  • Request22 29 04
  • Service 22DID 2904
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires total CUPRA_MISFIRES_TOTAL

  • Request22 11 46
  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Misfires, cylinder 1 CUPRA_MIS_1

  • Request22 10 F7
  • Service 22DID 10F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 1 CUPRA_MIS_1_V2

  • Request22 29 66
  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 1 CUPRA_MISFIRES_C1_FC00

  • Request22 29 66
  • Service 22DID 2966
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 2 CUPRA_MIS_2

  • Request22 10 FA
  • Service 22DID 10FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 2 CUPRA_MIS_2_V2

  • Request22 29 69
  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 2 CUPRA_MISFIRES_C2_V2

  • Request22 29 69
  • Service 22DID 2969
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 3 CUPRA_MIS_3

  • Request22 10 F8
  • Service 22DID 10F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 3 CUPRA_MIS_3_V2

  • Request22 29 67
  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 3 CUPRA_MISFIRES_C3_ECM

  • Request22 11 50
  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 3 CUPRA_MISFIRES_C3_FC00

  • Request22 29 67
  • Service 22DID 2967
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 4 CUPRA_MIS_4

  • Request22 10 F5
  • Service 22DID 10F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 4 CUPRA_MIS_4_V2

  • Request22 29 68
  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Misfires, cylinder 4 CUPRA_MISFIRES_C4_V2

  • Request22 29 68
  • Service 22DID 2968
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Mixture adaptation factor at partial load CUPRA_MIXTURE_ADPT_FACTOR

  • Request22 39 96
  • Service 22DID 3996
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2020 to 2026.

Motor temperature CUPRA_DIFF_MOTOR_T

  • Request22 F1 05
  • Service 22DID F105
  • Module71E → 788
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 50)
Range
-50 to 460 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

N_32 CUPRA_N_32

  • Request22 11 7D
  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 32)
Range
0 to 8160 rpm
Unit
rpm

In testing for 2020 to 2026.

NL_PRE, 0 CUPRA_NL_PRE_0

  • Request22 13 F6
  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 38147 ÷ 500000000)
Range
0 to 4.9999 V
Unit
V

In testing for 2020 to 2026.

NL_PRE, 1 CUPRA_NL_PRE_1

  • Request22 13 F7
  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 38147 ÷ 500000000)
Range
0 to 4.9999 V
Unit
V

In testing for 2020 to 2026.

NL_PRE, 2 CUPRA_NL_PRE_2

  • Request22 13 F8
  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 38147 ÷ 500000000)
Range
0 to 4.9999 V
Unit
V

In testing for 2020 to 2026.

NL_PRE, 3 CUPRA_NL_PRE_3

  • Request22 13 F9
  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 38147 ÷ 500000000)
Range
0 to 4.9999 V
Unit
V

In testing for 2020 to 2026.

Number of injections CUPRA_NUM_INJECTIONS

  • Request22 43 0E
  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Number of times the permitted centrifugal oil temperature has been exceeded CUPRA_NUM_TIMES_PERMITTED_T

  • Request22 11 54
  • Service 22DID 1154
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Number of warnings due to increased centrifugal oil temperature CUPRA_NUM_WARN_HI_CENTRIF_T

  • Request22 11 55
  • Service 22DID 1155
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

NV energy requirement CUPRA_NV_ENERGY

  • Request22 15 12
  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2020 to 2026.

Oil ash limit CUPRA_OIL_ASH_LIM

  • Request22 17 93
  • Service 22DID 1793
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Oil ash residue CUPRA_OIL_ASH_RESIDUE

  • Request22 17 8C
  • Service 22DID 178C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Oil ash residue CUPRA_OIL_ASH_RESIDUE_V2

  • Request22 20 8A
  • Service 22DID 208A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 3.052e-7)
Range
0 to 1310
Unit
Raw value

In testing for 2020 to 2026.

Oil dynamic average CUPRA_OIL_DYNAMIC_AVG

  • Request22 12 3F
  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2020 to 2026.

Oil dynamic average measurement CUPRA_PQ35_OIL_DYN_AVG

  • Request22 12 3F
  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Oil fill level CUPRA_OIL_FILL_LEVEL

  • Request22 20 06
  • Service 22DID 2006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.06)
Range
-1966.08 to 1966.02 mm
Unit
mm

In testing for 2020 to 2026.

Oil last dynamic measurement CUPRA_PQ35_OIL_DYN_LAST

  • Request22 12 3C
  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Oil last dynamic value CUPRA_OIL_LAST_DYNAMIC

  • Request22 12 3C
  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2020 to 2026.

Oil level CUPRA_OIL_LEVEL

  • Request22 11 BA
  • Service 22DID 11BA
  • Module7E0
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Oil level CUPRA_OIL_LVL

  • Request22 11 BA
  • Service 22DID 11BA
  • Module7E0
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2500)
Range
0 to 26.2 cm
Unit
cm

In testing for 2020 to 2026.

Oil level method 1 CUPRA_OIL_LEVEL_METHOD_1

  • Request22 1A F9
  • Service 22DID 1AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 %
Unit
%

In testing for 2020 to 2026.

Oil level method 2 CUPRA_OIL_LEVEL_METHOD_2

  • Request22 1A FA
  • Service 22DID 1AFA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 %
Unit
%

In testing for 2020 to 2026.

Oil level method 3 CUPRA_OIL_LEVEL_METHOD_3

  • Request22 1A FB
  • Service 22DID 1AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 %
Unit
%

In testing for 2020 to 2026.

Oil level test method 1 CUPRA_OIL_LEVEL_TEST_1

  • Request22 4E 51
  • Service 22DID 4E51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2020 to 2026.

Oil level test method 2 CUPRA_OIL_LEVEL_TEST_2

  • Request22 4E 52
  • Service 22DID 4E52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2020 to 2026.

Oil level test method 3 CUPRA_OIL_LEVEL_TEST_3

  • Request22 4E 53
  • Service 22DID 4E53
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2020 to 2026.

Oil level, average dynamic value CUPRA_OIL_LEVEL_AVG

  • Request22 15 B9
  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2020 to 2026.

Oil level, last dynamic value CUPRA_OIL_LEVEL_LAST

  • Request22 15 B8
  • Service 22DID 15B8
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2020 to 2026.

Oil level, last valid dynamic value CUPRA_OIL_LEVEL_LAST_VALID

  • Request22 10 F3
  • Service 22DID 10F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 127)
Range
-127 to 3968 mm
Unit
mm

In testing for 2020 to 2026.

Oil level, static measured CUPRA_OIL_LEVEL_STATIC_V2

  • Request22 15 A4
  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

In testing for 2020 to 2026.

Oil level, static measurement CUPRA_OIL_LEVEL_STATIC

  • Request22 40 CE
  • Service 22DID 40CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 127)
Range
-127 to 3968 mm
Unit
mm

In testing for 2020 to 2026.

Oil maximum level CUPRA_PQ35_OIL_LVL_MAX

  • Request22 11 C4
  • Service 22DID 11C4
  • Module7E0
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Oil minimum level CUPRA_PQ35_OIL_LVL_MIN

  • Request22 11 C5
  • Service 22DID 11C5
  • Module7E0
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Oil p CUPRA_OIL_P

  • Request22 25 CD
  • Service 22DID 25CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2020 to 2026.

Oil pressure 1 CUPRA_OIL_P_1

  • Request22 2B 05
  • Service 22DID 2B05
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 bar
Unit
bar

In testing for 2020 to 2026.

Oil pressure 2 CUPRA_OIL_P_2

  • Request22 2B 06
  • Service 22DID 2B06
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 bar
Unit
bar

In testing for 2020 to 2026.

Oil pressure actual CUPRA_MQB_TCM_EOP_ACTUALConfirmed

  • Request22 38 1D
  • Service 22DID 381D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 × 100 ÷ 10000) = 0 bar

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 bar
Unit
bar

Confirmed for 2021. In testing for 2020, 2022. Not supported for 2023 to 2026.

Oil pressure actual current CUPRA_MQB_TCM_EOP_ACTUAL_IConfirmed

  • Request22 38 1E
  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x000A = 10 → (10 ÷ 10) = 1 mA

Formula
(val ÷ 10)
Range
0 to 6553.5 mA
Unit
mA

Confirmed for 2021. In testing for 2020, 2022. Not supported for 2023 to 2026.

Oil pressure control valve activation pulse duty factor CUPRA_OIL_P_CTRL_VLV

  • Request22 25 D0
  • Service 22DID 25D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Oil pressure control valve, activation pulse duty factor CUPRA_OIL_P_CTRL_VLV_ACTIVATION

  • Request22 4F 97
  • Service 22DID 4F97
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Oil pressure sensor raw value CUPRA_OIL_P_SENS_RAW_V2

  • Request22 4F BE
  • Service 22DID 4FBE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2020 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status CUPRA_OIL_P_SENS_PISTON

  • Request22 15 BD
  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Oil pressure sensor, raw value CUPRA_OIL_P_SENS_RAW

  • Request22 1B 02
  • Service 22DID 1B02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Oil pressure switch activation, high pressure CUPRA_OIL_P_SWITCH_P

  • Request22 20 A2
  • Service 22DID 20A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Oil pressure switch for high pressure, closed CUPRA_OIL_P_SWITCH_HIGH_P

  • Request22 20 A3
  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Oil pressure switch for low pressure, closed CUPRA_OIL_P_SWITCH_LOW_P

  • Request22 20 A3
  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Oil pressure switch for piston-cooling jets, closed CUPRA_OIL_P_SWITCH_PISTON

  • Request22 42 70
  • Service 22DID 4270
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Oil pressure switch valve activation CUPRA_OIL_P_SWITCH_VLV

  • Request22 13 B8
  • Service 22DID 13B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Oil pressure target CUPRA_OIL_P_TGT

  • Request22 25 CF
  • Service 22DID 25CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2020 to 2026.

Oil pressure target CUPRA_OIL_P_TGT_7E0

  • Request22 4F 70
  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2020 to 2026.

Oil pressure target CUPRA_OIL_P_TGT_V2

  • Request22 4F 70
  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2020 to 2026.

Oil pressure valve for piston cooling nozzles, control switch button ratio CUPRA_OIL_P_VLV_PISTON

  • Request22 2C D8
  • Service 22DID 2CD8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Oil pressure valve switch, control CUPRA_OIL_P_VLV_SWITCH

  • Request22 11 B9
  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Oil pressure, actual value CUPRA_OIL_P_ACT

  • Request22 17 7D
  • Service 22DID 177D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2020 to 2026.

Oil pressure, actual value CUPRA_OIL_P_ACT_7E0_2

  • Request22 38 1D
  • Service 22DID 381D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2020 to 2026.

Oil pressure, actual value CUPRA_OIL_P_ACT_7E0_2_V2

  • Request22 1B 04
  • Service 22DID 1B04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Oil sensor temperature 1 CUPRA_OIL_SENS_T_1

  • Request22 2B 03
  • Service 22DID 2B03
  • Module71D → 787
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Oil sensor temperature 2 CUPRA_OIL_SENS_T_2

  • Request22 2B 04
  • Service 22DID 2B04
  • Module71D → 787
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Oil sump temperature CUPRA_OIL_SUMP_T

  • Request22 15 B7
  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Oil temp 2 CUPRA_ENGINE_OIL_T_2

  • Request22 17 9C
  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020 to 2026.

Oil temperature CUPRA_DIFF_OIL_T

  • Request22 F1 05
  • Service 22DID F105
  • Module71E → 788
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 2 − 50)
Range
-50 to 460 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Oil temperature CUPRA_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 A7
  • Service 22DID 10A7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Oil temperature CUPRA_PQ35_OIL_TConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 20 2F
  • Service 22DID 202F
  • Module714 → 77E
  • Every30 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x66 = 102 → (102 − 58) = 44 °C

Formula
(val − 58)
Range
-58 to 197 °C
Unit
°C

Confirmed for 2021. In testing for 2022. Not supported for 2020, 2023 to 2026.

Oil temperature variant CUPRA_PQ35_OIL_T_2

  • Request22 11 BE
  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Oil temperature variant CUPRA_PQ46_OIL_T_2

Pelican can show this parameter as the engine oil temperature.

  • Request22 11 BE
  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Oil thermal wear CUPRA_DASH_OIL_THERMAL_WEAR

  • Request22 22 4B
  • Service 22DID 224B
  • Module714 → 77E
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Oil warning threshold CUPRA_OIL_WARN_THR

  • Request22 20 07
  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mm
Unit
mm

In testing for 2020 to 2026.

Open cam shaft angle at quantity control valve CUPRA_OPEN_CAM_SHFT_ANG

  • Request22 10 EA
  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2020 to 2026.

Open camshaft angle at quantity control valve CUPRA_OPEN_CAM_ANG_QTY

  • Request22 10 E1
  • Service 22DID 10E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 2020 to 2026.

Outside temperature CUPRA_OUTSIDE_T

  • Request22 22 0C
  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 50)
Range
-50 to 77.5 °C
Unit
°C

In testing for 2020 to 2026.

Outside temperature CUPRA_PQ35_OUT_TConfirmed

  • Request22 26 09
  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x86 = -122 → (-122 ÷ 2) = -61 °C

Formula
(val ÷ 2)
Range
-64 to 63.5 °C
Unit
°C

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Outside temperature, system calculated CUPRA_OUTSIDE_T_SYSTEM

  • Request22 26 0A
  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 2)
Range
-64 to 63.5 °C
Unit
°C

In testing for 2020 to 2026.

Overall energy balance CUPRA_OVERALL_ENERGY

  • Request22 2A 17
  • Service 22DID 2A17
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
(val × 21 ÷ 20)
Range
-8808038 to 8808037 Ah
Unit
Ah

In testing for 2020 to 2026.

Oxygen control, adaptation value at part. load CUPRA_OXYGEN_CTRL_ADPT

  • Request22 39 A9
  • Service 22DID 39A9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature CUPRA_OXYGEN_SNS_1_BANK_1_CERAMIC_T

  • Request22 12 90
  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 234.37 ÷ 10000 − 273.15)
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Oxygen sensor 1 bank 1 ceramic temperature CUPRA_OXYGEN_SNS_1_BANK_1_CERAMIC_T_V2

  • Request22 12 90
  • Service 22DID 1290
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 234.37 ÷ 10000 − 273.15)
Range
-273.15 to 1262 °C
Unit
°C

In testing for 2020 to 2026.

Oxygen sensor 1 bank 1 lambda value CUPRA_PQ35_O2_SEN_1_LAMBDA

  • Request22 11 3D
  • Service 22DID 113D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Particle filter, field regeneration request status CUPRA_PARTICLE_FLT_FIELD

  • Request22 11 5B
  • Service 22DID 115B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Particle sensor, cleaning deviation reaction time CUPRA_PARTICLE_SENS

  • Request22 44 F5
  • Service 22DID 44F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.76 to 32.76
Unit
Number

In testing for 2020 to 2026.

Particle sensor, exhaust temperature CUPRA_PARTICLE_SENS_EXH_T

  • Request22 44 F8
  • Service 22DID 44F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2020 to 2026.

Particle sensor, soot volume in exhaust CUPRA_PARTICLE_SENS_SOOT

  • Request22 44 F7
  • Service 22DID 44F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2020 to 2026.

Particle sensor, surface temperature CUPRA_PARTICLE_SENS_T

  • Request22 44 FB
  • Service 22DID 44FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16 − 273.15)
Range
-2321 to 1774 °C
Unit
°C

In testing for 2020 to 2026.

Particle sensor, time in op.mode measurement CUPRA_PARTICLE_SENS_TIME

  • Request22 46 D4
  • Service 22DID 46D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 s
Unit
s

In testing for 2020 to 2026.

Particulate filter air pressure sensor raw value CUPRA_MQB_DPF_AIR_P_SENSOR_RAW_VALUE

  • Request22 16 2F
  • Service 22DID 162F
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Particulate filter differential pressure, dynamic offset CUPRA_DPF_DIFF_P_DYNAMIC_OFFSET

  • Request22 15 B8
  • Service 22DID 15B8
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Particulate filter differential pressure, filtered CUPRA_PF_DIFF_P_FILTERED

  • Request22 10 40
  • Service 22DID 1040
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4 − 5000)
Range
-5000 to 11383.75
Unit
Raw value

In testing for 2020 to 2026.

Pilot injection 1 duration CUPRA_PQ35_PRE_INJ_1_DURATION

  • Request22 14 D0
  • Service 22DID 14D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Pilot injection 1 start position CUPRA_PQ35_PRE_INJ_1_START

  • Request22 14 C7
  • Service 22DID 14C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Pilot injection 2 start CUPRA_PQ35_PRE_INJ_2_START

  • Request22 14 C8
  • Service 22DID 14C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Pilot injection 3 start CUPRA_PRE_INJ_3_START

  • Request22 16 31
  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 21973 ÷ 1000000)
Range
-720 to 719 °
Unit
°

In testing for 2020 to 2026.

Piston cooling nozzles, control CUPRA_PISTON_COOLING

  • Request22 16 F4
  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Piston-cooling jets, activation CUPRA_PISTON_COOLING_JETS

  • Request22 42 86
  • Service 22DID 4286
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Port injection injections counter CUPRA_PORT_INJ_INJECTIONS

  • Request22 42 68
  • Service 22DID 4268
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2020 to 2026.

Post injection 1 CUPRA_POST_INJ_1

  • Request22 08 1A
  • Service 22DID 081A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Post injection 1 CUPRA_POST_INJ_1_7E0

  • Request22 20 5D
  • Service 22DID 205D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

In testing for 2020 to 2026.

Post injection 1, quantity specified value CUPRA_POST_INJ_1_QTY_SPEC

  • Request22 16 3C
  • Service 22DID 163C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655
Unit
Raw value

In testing for 2020 to 2026.

Post injection 1: quantity specified value CUPRA_PQ35_POST_INJ_1_QTY_SPEC

  • Request22 16 3C
  • Service 22DID 163C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Post injection 2 CUPRA_POST_INJ_2_7E0

  • Request22 20 5F
  • Service 22DID 205F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

In testing for 2020 to 2026.

Post injection 2 CUPRA_POST_INJ_2_V2

  • Request22 08 0C
  • Service 22DID 080C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Post injection 2, quantity specified value CUPRA_POST_INJ_2_QTY_SPEC

  • Request22 16 3B
  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655
Unit
Raw value

In testing for 2020 to 2026.

Post injection 2: quantity specified value CUPRA_PQ35_POST_INJ_2_QTY_SPEC

  • Request22 16 3B
  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Post injection 3 CUPRA_POST_INJ_3_7E0

  • Request22 20 C0
  • Service 22DID 20C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

In testing for 2020 to 2026.

Post injection 3 CUPRA_POST_INJ_3_V2

  • Request22 08 1B
  • Service 22DID 081B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

In testing for 2020 to 2026.

Post injection 3, quantity specified value CUPRA_POST_INJ_3_QTY_SPEC

  • Request22 16 7D
  • Service 22DID 167D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655
Unit
Raw value

In testing for 2020 to 2026.

Post injection 3: quantity specified value CUPRA_PQ35_POST_INJ_3_QTY_SPEC

  • Request22 16 7D
  • Service 22DID 167D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Post-injection 1 duration CUPRA_PQ35_POST_INJ_1_DURATION

  • Request22 14 CC
  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Post-injection 1 start position CUPRA_PQ35_POST_INJ_1_START

  • Request22 11 F4
  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Post-injection 1, duration CUPRA_POST_INJ_1_DUR

  • Request22 14 CC
  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2500)
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2020 to 2026.

Post-injection 1, start CUPRA_POST_INJ_1_START

  • Request22 11 F4
  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Post-injection 2 duration CUPRA_PQ35_POST_INJ_2_DURATION

  • Request22 14 CD
  • Service 22DID 14CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Post-injection 2 start position CUPRA_PQ35_POST_INJ_2_START

  • Request22 11 F3
  • Service 22DID 11F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Post-injection 2, activation duration CUPRA_POST_INJ_2

  • Request22 12 1B
  • Service 22DID 121B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2500)
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2020 to 2026.

Post-injection 2, duration CUPRA_POST_INJ_2_DUR

  • Request22 14 CD
  • Service 22DID 14CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2500)
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2020 to 2026.

Post-injection 2, start CUPRA_POST_INJ_2_START

  • Request22 11 F3
  • Service 22DID 11F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Post-injection 3 activation duration CUPRA_POST_INJ_3_ACTIVATION_DURATION

  • Request22 14 CE
  • Service 22DID 14CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2020 to 2026.

Post-injection 3 start position CUPRA_PQ35_POST_INJ_3_START

  • Request22 11 31
  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Post-injection 3, activation start CUPRA_POST_INJ_3

  • Request22 11 31
  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Power electronics internal supply voltage 1 CUPRA_PE_SUPPLY_V1

  • Request22 46 6C
  • Service 22DID 466C
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.998 V
Unit
V

In testing for 2020 to 2026.

Power electronics internal supply voltage 2 CUPRA_PE_SUPPLY_V2

  • Request22 46 6B
  • Service 22DID 466B
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.998 V
Unit
V

In testing for 2020 to 2026.

Power electronics phase u transistor temperature CUPRA_PE_IGBT_U_T

  • Request22 46 64
  • Service 22DID 4664
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2020 to 2026.

Power electronics phase v transistor temperature CUPRA_PE_IGBT_V_T

  • Request22 46 63
  • Service 22DID 4663
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2020 to 2026.

Power electronics phase w transistor temperature CUPRA_PE_IGBT_W_T

  • Request22 46 62
  • Service 22DID 4662
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2020 to 2026.

Power electronics traction voltage CUPRA_PE_HV_V

  • Request22 46 75
  • Service 22DID 4675
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.968 V
Unit
V

In testing for 2020 to 2026.

Power electronics transistor supply voltage CUPRA_PE_IGBT_SUPPLY_V

  • Request22 46 5A
  • Service 22DID 465A
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 512)
Range
-64 to 63.998 V
Unit
V

In testing for 2020 to 2026.

Pre-injection 1, activation start CUPRA_PRE_INJ_1_ACTIVATION

  • Request22 12 C8
  • Service 22DID 12C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Pre-injection 2, activation start CUPRA_PRE_INJ_2_ACTIVATION

  • Request22 12 C7
  • Service 22DID 12C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Pre-injection 3, activation duration CUPRA_PRE_INJ_3_ACTIVATION

  • Request22 12 1A
  • Service 22DID 121A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2500)
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2020 to 2026.

Pre-injection 3, activation start CUPRA_PRE_INJ_3_ACTIVATION_START

  • Request22 12 1D
  • Service 22DID 121D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Preheat time CUPRA_PREHEAT_TIME

  • Request22 11 1F
  • Service 22DID 111F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100)
Range
-3276800 to 3276700 ms
Unit
ms

In testing for 2020 to 2026.

Pressure before throttle valve - actual value CUPRA_P_BEFORE_THROTTLE_ACT

  • Request22 11 EE
  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119.9218
Unit
Raw value

In testing for 2020 to 2026.

Pressure before throttle valve - sensor measured CUPRA_P_BEFORE_THROTTLE

  • Request22 11 EF
  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 21333 ÷ 546125)
Range
0 to 2559.96
Unit
Raw value

In testing for 2020 to 2026.

Pressure sensor 1 temperature CUPRA_P_SENS_1_T

  • Request22 13 2A
  • Service 22DID 132A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Pressure sensor 2 temperature CUPRA_P_SENS_2_T

  • Request22 13 2B
  • Service 22DID 132B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Pressure supply actual pressure CUPRA_MQB_DQ200_P_SUPPLY_ACTUAL_PConfirmed

  • Request22 11 91
  • Service 22DID 1191
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Example reply from a 2024 Cupra Leon.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x0FC7 = 4039 → (4039 ÷ 100) = 40.39 bar

Formula
(val ÷ 100)
Range
-327.68 to 327.67 bar
Unit
bar

Confirmed for 2021, 2024. In testing for 2020, 2022. Not supported for 2023, 2025 to 2026.

Pressure supply actual pressure analog digital value CUPRA_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE

  • Request22 10 2D
  • Service 22DID 102D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 CUPRA_PSN_EDGE_REL_AD_CAM_1

  • Request22 11 84
  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2020 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_2 CUPRA_PSN_EDGE_REL_AD_CAM_2

  • Request22 11 85
  • Service 22DID 1185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2020 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_IN_1 CUPRA_PSN_EDGE_REL_AD_CAM_SAVE_1

  • Request22 11 86
  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2020 to 2026.

Radiator fan 1, commanded duty CUPRA_RADIATOR_FAN_1_CMD

  • Request22 10 9E
  • Service 22DID 109E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Radiator fan 2, commanded duty CUPRA_RADIATOR_FAN_2_CMD

  • Request22 10 9C
  • Service 22DID 109C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

Radiator fan actual duty CUPRA_CLIMATE_RAD_FAN_ACT_DUTYConfirmed

  • Request22 26 06
  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x0A = 10 → (10 ÷ 2.5) = 4 %

Formula
(val ÷ 2.5)
Range
0 to 100 %
Unit
%

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Radiator fan commanded duty CUPRA_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Request22 26 07
  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2.5) = 0 %

Formula
(val ÷ 2.5)
Range
0 to 100 %
Unit
%

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Radiator fan duty CUPRA_RADIATOR_FAN_DUTY

  • Request22 20 55
  • Service 22DID 2055
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Radiator outlet coolant temperature commanded CUPRA_PQ35_RAD_COOL_T_CMD

  • Request22 11 11
  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Radiator output coolant temp: actual CUPRA_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL

  • Request22 16 26
  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Radiator output coolant temperature, actual CUPRA_RADIATOR_OUTPUT_ECT_ACT

  • Request22 16 26
  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Radiator output coolant temperature, commanded CUPRA_RADIATOR_OUTPUT_ECT_CMD

  • Request22 11 11
  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Rated drive torque CUPRA_RATED_DRIVE_TQ

  • Request22 14 A1
  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2020 to 2026.

Reached maximum temperature CUPRA_REACHED_MAXIMUM_T

  • Request22 11 17
  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Rear cat converter temperature, main catalytic converter model value CUPRA_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE

  • Request22 12 72
  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Rear catalytic converter temperature, main catalytic converter model value CUPRA_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE_V2

  • Request22 12 72
  • Service 22DID 1272
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2020 to 2026.

Rear deflector temperature CUPRA_CLIMATE_RR_DEFL_T

  • Request22 26 3D
  • Service 22DID 263D
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 3)
Range
0 to 84.915 °C
Unit
°C

In testing for 2020 to 2026.

Reducing agent tank volume, act. value filtered CUPRA_REDUCING_AGENT_TANK_ACT

  • Request22 1A 6C
  • Service 22DID 1A6C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 131 L
Unit
L

In testing for 2020 to 2026.

Refrigerant pressure CUPRA_CLIMATE_REFRIG_PConfirmed

  • Request22 26 05
  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x1C = 28 → (28 ÷ 5) = 5.6 bar

Formula
(val ÷ 5)
Range
0 to 51 bar
Unit
bar

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Refrigerant pressure CUPRA_REFRIGERANT_P

  • Request22 26 05
  • Service 22DID 2605
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 bar
Unit
bar

In testing for 2020 to 2026.

Regen. duration CUPRA_REGEN_DUR

  • Request22 13 47
  • Service 22DID 1347
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 6000)
Range
0 to 715827 min
Unit
min

In testing for 2020 to 2026.

Regeneration duration CUPRA_REGEN_DUR_V2

  • Request22 39 F9
  • Service 22DID 39F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 60)
Range
0 to 1092.25 min
Unit
min

In testing for 2020 to 2026.

Regulation factor total CUPRA_PQ35_REG_FACTOR

  • Request22 10 E4
  • Service 22DID 10E4
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10000)
Range
0 to 3.276 %
Unit
%

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Relative load value CUPRA_REL_LOAD

  • Request22 12 16
  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0234403081)
Range
0 to 1536.1605
Unit
Number

In testing for 2020 to 2026.

Relay for reserve coolant pump status CUPRA_RELAY_RESERVE_CLT

  • Request22 39 99
  • Service 22DID 3999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Requested torque, amount for auxiliary units CUPRA_REQ_TQ_AMOUNT

  • Request22 10 BE
  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Reserve torque CUPRA_RESERVE_TQ

  • Request22 10 6A
  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2026.

Result of crankcase ventilation test, fail CUPRA_RESULT_CRANKCASE

  • Request22 15 CC
  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Result of crankcase ventilation test, successful CUPRA_RESULT_CRANKCASE_VENTILATION_TEST

  • Request22 15 CB
  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Right central air outlet temperature CUPRA_RIGHT_CENTRAL_AIR_T

  • Request22 42 C6
  • Service 22DID 42C6
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Right footwell air outlet temperature CUPRA_RIGHT_FOOTWELL_AIR_T

  • Request22 42 BD
  • Service 22DID 42BD
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Right rear footwell air outlet temperature CUPRA_RIGHT_REAR_FOOTWELL_T

  • Request22 42 C2
  • Service 22DID 42C2
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Right rear upper air outlet temperature CUPRA_RIGHT_REAR_HI_AIR_T

  • Request22 42 C0
  • Service 22DID 42C0
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Right side air outlet temperature CUPRA_RIGHT_SIDE_AIR_T

  • Request22 42 C4
  • Service 22DID 42C4
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2020 to 2026.

Rotor position sensor cosine amplitude CUPRA_ROTOR_COS_AMP_V

  • Request22 4E 91
  • Service 22DID 4E91
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.998 V
Unit
V

In testing for 2020 to 2026.

Rotor position sensor cosine offset CUPRA_ROTOR_COS_OFS_V

  • Request22 4E 93
  • Service 22DID 4E93
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.998 V
Unit
V

In testing for 2020 to 2026.

Rotor position sensor cosine track CUPRA_ROTOR_COS

  • Request22 46 61
  • Service 22DID 4661
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Rotor position sensor sine amplitude CUPRA_ROTOR_SIN_AMP_V

  • Request22 4E 90
  • Service 22DID 4E90
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.998 V
Unit
V

In testing for 2020 to 2026.

Rotor position sensor sine track CUPRA_ROTOR_SIN

  • Request22 46 60
  • Service 22DID 4660
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Rotor position sensor sine voltage CUPRA_ROTOR_SIN_V

  • Request22 4E 92
  • Service 22DID 4E92
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.998 V
Unit
V

In testing for 2020 to 2026.

Rotor temperature model CUPRA_ROTOR_T_MODEL

  • Request22 2C CC
  • Service 22DID 2CCC
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2022, 2025. Not supported for 2020 to 2021, 2023 to 2024, 2026.

Route data, active CUPRA_ROUTE_DATA_ACTIVE

  • Request22 28 2C
  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Second pilot injection, duration CUPRA_PRE_INJ_2_DURATION

  • Request22 14 D1
  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2020 to 2026.

Second pilot injection, start CUPRA_PRE_INJ_2_START

  • Request22 14 C8
  • Service 22DID 14C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 °
Unit
°

In testing for 2020 to 2026.

Secondary air injection sensor 1 CUPRA_SECONDARY_AIR_INJ_1

  • Request22 3F 68
  • Service 22DID 3F68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 bar
Unit
bar

In testing for 2020 to 2026.

SEG_AD_MMV_ER_H, 0 CUPRA_SEG_AD_MMV_ER_H_0

  • Request22 11 38
  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER_H, 2 CUPRA_SEG_AD_MMV_ER_H_2

  • Request22 11 3A
  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER_H, 3 CUPRA_SEG_AD_MMV_ER_H_3

  • Request22 11 3B
  • Service 22DID 113B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER_L, 0 CUPRA_SEG_AD_MMV_ER_L_0

  • Request22 11 3E
  • Service 22DID 113E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER_L, 2 CUPRA_SEG_AD_MMV_ER_L_2

  • Request22 11 40
  • Service 22DID 1140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER_L, 3 CUPRA_SEG_AD_MMV_ER_L_3

  • Request22 11 41
  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER_MID, 0 CUPRA_SEG_AD_MMV_ER_MID_0

  • Request22 11 32
  • Service 22DID 1132
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER_MID, 1 CUPRA_SEG_AD_MMV_ER_MID_1

  • Request22 11 33
  • Service 22DID 1133
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER_MID, 2 CUPRA_SEG_AD_MMV_ER_MID_2

  • Request22 11 34
  • Service 22DID 1134
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER, 1 CUPRA_SEG_AD_MMV_ER_1

  • Request22 11 2D
  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER, 2 CUPRA_SEG_AD_MMV_ER_2

  • Request22 11 2E
  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

SEG_AD_MMV_ER, 3 CUPRA_SEG_AD_MMV_ER_3

  • Request22 11 2F
  • Service 22DID 112F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 78123 ÷ 327670000)
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2020 to 2026.

Sensor for particle filter differential pressure, raw value CUPRA_SENS_PARTICLE_FLT_P

  • Request22 39 E9
  • Service 22DID 39E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020 to 2026.

Service interval extension, max oil level CUPRA_WIV_MAX_OIL_LEVEL

  • Request22 12 30
  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2020 to 2026.

Service interval extension, min oil level CUPRA_WIV_MIN_OIL_LEVEL

  • Request22 12 31
  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2020 to 2026.

Service limit CUPRA_SERVICE_LIM

  • Request22 12 CB
  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655
Unit
Raw value

In testing for 2020 to 2026.

Service limit CUPRA_SERVICE_LIM_7E0

  • Request22 58 51
  • Service 22DID 5851
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020 to 2026.

Service limit CUPRA_SERVICE_LIM_V2

  • Request22 20 DA
  • Service 22DID 20DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020 to 2026.

Service limit value CUPRA_PQ35_SRV_LIM

  • Request22 12 CB
  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Service regeneration current duration CUPRA_SERVICE_REGEN

  • Request22 11 C3
  • Service 22DID 11C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 100)
Range
0 to 42949672 s
Unit
s

In testing for 2020 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021, 2023 to 2026.

Shunt temperature CUPRA_BMS_SHUNT_T

  • Request22 18 0F
  • Service 22DID 180F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

SIM card, SIM card in main unit CUPRA_SIM_CARD_SIM_CARD

  • Request22 18 14
  • Service 22DID 1814
  • Module773 → 7DD
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Simulated DPF temperature CUPRA_SIMULATED_DPF_T

  • Request22 3D 7F
  • Service 22DID 3D7F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2020 to 2026.

Smoke limit CUPRA_PQ35_LIM_SMOKE

  • Request22 13 01
  • Service 22DID 1301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Soot mass calculated CUPRA_SOOT_MASS_CALC

  • Request22 20 8B
  • Service 22DID 208B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020 to 2026.

Soot mass measured CUPRA_SOOT_MASS_MEAS_V2

  • Request22 20 8C
  • Service 22DID 208C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127
Unit
Raw value

In testing for 2020 to 2026.

Spark efficiency deviation at idle CUPRA_SPARK_EFFICIENCY_DEV

  • Request22 11 2C
  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 781 ÷ 1000)
Range
0 to 199 %
Unit
%

In testing for 2020 to 2026.

Spark efficiency deviation at idle, maximum CUPRA_SPARK_EFFICIENCY_DEV_MAX

  • Request22 15 5B
  • Service 22DID 155B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Spark efficiency deviation at part load CUPRA_SPARK_EFF_DEV

  • Request22 11 2D
  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 78.1 ÷ 100)
Range
0 to 199.14 %
Unit
%

In testing for 2020 to 2026.

Spark efficiency deviation at part load CUPRA_SPARK_EFF_DEV_PART

  • Request22 11 2D
  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 78.1 ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Spark efficiency deviation at part load CUPRA_SPARK_EFFICIENCY_DEV_V2

  • Request22 11 2D
  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 781 ÷ 1000)
Range
0 to 199 %
Unit
%

In testing for 2020 to 2026.

Spark efficiency deviation at part load, maximum CUPRA_SPARK_EFFICIENCY_DEV_PART_MAX

  • Request22 15 5C
  • Service 22DID 155C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Static torque limitation CUPRA_STATIC_TQ_LIM

  • Request22 10 66
  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2026.

Status CC ECU, temperature. st.disc CUPRA_STAT_CC_ECU_T_ST

  • Request22 11 0A
  • Service 22DID 110A
  • Module70F → 779
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2020 to 2026.

Stop signal switch CUPRA_MQB_TCM_STOP_SIGNAL_SWITCHConfirmed

  • Request22 38 00
  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Example reply from a 2021 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021. In testing for 2020, 2022, 2024. Not supported for 2023, 2025 to 2026.

Sum of misfires counter CUPRA_SUM_MIS_CNT

  • Request22 10 F2
  • Service 22DID 10F2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Tank fill level diagnostic reference value CUPRA_TANK_FILL_LEVEL

  • Request22 51 D8
  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 L
Unit
L

In testing for 2020 to 2026.

TCO_1_ST CUPRA_TCO_1_ST

  • Request22 11 D0
  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

TCO_1_SYS CUPRA_TCO_1_SYS

  • Request22 11 CD
  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Temperature after evaporator CUPRA_CLIMATE_T_AFTER_EVAP

  • Request22 26 12
  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 3)
Range
-42.624 to 42.291 °C
Unit
°C

In testing for 2020 to 2026.

Temperature after evaporator CUPRA_PQ35_EVAP_OUT_TConfirmed

  • Request22 26 12
  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing

Example reply from a 2026 Cupra Leon.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x01 = 1 → (1 × 0.333) = 0.333 °C

Formula
(val × 0.333)
Range
-42.624 to 42.291 °C
Unit
°C

Confirmed for 2020 to 2021, 2023 to 2026. In testing for 2022.

Temperature at air conditioner heat exchanger output CUPRA_T_AC_HEAT_EXCHANGER

  • Request22 11 77
  • Service 22DID 1177
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Temperature sensor 14 CUPRA_T_SENS_14

  • Request22 1E BB
  • Service 22DID 1EBB
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

In testing for 2020 to 2026.

Temperature sensor for engine temperature management CUPRA_T_SENS_ENG_T

  • Request22 39 2A
  • Service 22DID 392A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Temperature sensor for engine temperature management, target value CUPRA_T_SENS_ENG_T_TGT

  • Request22 40 E2
  • Service 22DID 40E2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2020 to 2026.

Temperature status, controller CUPRA_STAT_NIA_T

  • Request22 11 01
  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 136 to 151 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Temperature status, RPS CUPRA_STAT_NIA_T_RPS

  • Request22 11 01
  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 152 to 167 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Temperature status, SBC CUPRA_STAT_NIA_T_SBC

  • Request22 11 01
  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Temperature, electric drive inflow coolant CUPRA_ELEC_DRIVE_INFLOW_COOLANT_T

  • Request22 4F AE
  • Service 22DID 4FAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2022, 2025. Not supported for 2020 to 2021, 2023 to 2024, 2026.

Temperature, motor CUPRA_MOTOR_T

  • Request22 46 72
  • Service 22DID 4672
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2022, 2025. Not supported for 2020 to 2021, 2023 to 2024, 2026.

Test of catalytic converter status, canceled CUPRA_TEST_CATALYTIC_CONV_STAT

  • Request22 29 27
  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Test of catalytic converter, measured value CUPRA_TEST_CATALYTIC_CONV

  • Request22 29 26
  • Service 22DID 2926
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535
Unit
Number

In testing for 2020 to 2026.

Thermal load of AWD drive pump CUPRA_THERMAL_LOAD_AWD

  • Request22 2B 09
  • Service 22DID 2B09
  • Module71D → 787
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2020 to 2026.

Thermostat, actual CUPRA_THERMOSTAT_ACT

  • Request22 44 18
  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12207 ÷ 1000000)
Range
0 to 799 %
Unit
%

In testing for 2020 to 2026.

Thermostat, commanded CUPRA_THERMOSTAT_CMD

  • Request22 44 17
  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12207 ÷ 1000000)
Range
0 to 799 %
Unit
%

In testing for 2020 to 2026.

Throttle regulator nominal value CUPRA_THROTTLE_REGULATOR

  • Request22 16 C5
  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Throttle valve adapter position CUPRA_PQ35_THROT_VALVE_ADAPT

  • Request22 12 FC
  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Throttle valve adapter, actual value CUPRA_THROTTLE_VLV_ADAPTER_ACT

  • Request22 12 FC
  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2020 to 2026.

TI_1_MPI, 0 CUPRA_TI_1_MPI_0

  • Request22 13 AC
  • Service 22DID 13AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_1_MPI, 1 CUPRA_TI_1_MPI_1

  • Request22 13 AD
  • Service 22DID 13AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_1_MPI, 2 CUPRA_TI_1_MPI_2

  • Request22 13 AE
  • Service 22DID 13AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_1_MPI, 3 CUPRA_TI_1_MPI_3

  • Request22 13 AF
  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_1, 1 CUPRA_TI_MES4_PLS_1_1

  • Request22 13 A1
  • Service 22DID 13A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_1, 2 CUPRA_TI_MES4_PLS_1_2

  • Request22 13 A2
  • Service 22DID 13A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_1, 3 CUPRA_TI_MES4_PLS_1_3

  • Request22 13 A3
  • Service 22DID 13A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_2, 0 CUPRA_TI_MES4_PLS_2_0

  • Request22 13 A4
  • Service 22DID 13A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_2, 1 CUPRA_TI_MES4_PLS_2_1

  • Request22 13 A5
  • Service 22DID 13A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_2, 2 CUPRA_TI_MES4_PLS_2_2

  • Request22 13 A6
  • Service 22DID 13A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_2, 3 CUPRA_TI_MES4_PLS_2_3

  • Request22 13 A7
  • Service 22DID 13A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_3, 0 CUPRA_TI_MES4_PLS_3_0

  • Request22 13 A8
  • Service 22DID 13A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_3, 1 CUPRA_TI_MES4_PLS_3_1

  • Request22 13 A9
  • Service 22DID 13A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_3, 2 CUPRA_TI_MES4_PLS_3_2

  • Request22 13 AA
  • Service 22DID 13AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

TI_MES4_PLS_3, 3 CUPRA_TI_MES4_PLS_3_3

  • Request22 13 AB
  • Service 22DID 13AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2020 to 2026.

Time in run-on after shutdown CUPRA_TIME_AFTERRUN

  • Request22 10 3A
  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2020 to 2026.

Time since last regen. CUPRA_TIME_SINCE_REGEN

  • Request22 11 5E
  • Service 22DID 115E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 60)
Range
0 to 71582788 min
Unit
min

In testing for 2020 to 2026.

Time since last regeneration CUPRA_TIME_SINCE_REGEN_V2

  • Request22 20 89
  • Service 22DID 2089
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2020 to 2026.

Time since reset CUPRA_TIME_SINCE_RESET

  • Request22 10 3B
  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 30)
Range
0 to 7650 ms
Unit
ms

In testing for 2020 to 2026.

Time with transmission fluid above 135 degrees CUPRA_ANALYSIS_40_ATF_T_135_C

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
(val ÷ 5)
Range
0 to 858993459 s
Unit
s

In testing for 2020 to 2026.

Time with transmission fluid at 65 to 80 degrees CUPRA_ANALYSIS_40_ATF_T_65_C_80_C

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 5)
Range
0 to 858993459 s
Unit
s

In testing for 2020 to 2026.

Time with transmission fluid at 80 to 110 degrees CUPRA_ANALYSIS_40_ATF_T_80_C_110_C

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
(val ÷ 5)
Range
0 to 858993459 s
Unit
s

In testing for 2020 to 2026.

Time with transmission fluid at 110 to 135 degrees CUPRA_ANALYSIS_40_ATF_T_110_C_135_C

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
(val ÷ 5)
Range
0 to 858993459 s
Unit
s

In testing for 2020 to 2026.

Time with transmission fluid below 65 degrees CUPRA_ANALYSIS_40_ATF_T_65_C

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 5)
Range
0 to 858993459 s
Unit
s

In testing for 2020 to 2026.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2023. Supported for 2021, 2024 to 2026.

Timing angle retardation cylinder 1 CUPRA_TIMING_ANGLE_RETARDATION_CYL_1

  • Request22 20 0A
  • Service 22DID 200A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.375 − 48)
Range
-48 to 47.625 °
Unit
°

In testing for 2020 to 2026.

Timing angle retardation cylinder 2 CUPRA_TIMING_ANGLE_RETARDATION_CYL_2

  • Request22 20 0B
  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.375 − 48)
Range
-48 to 47.625 °
Unit
°

In testing for 2020 to 2026.

Timing angle retardation cylinder 3 CUPRA_TIMING_ANGLE_RETARDATION_CYL_3

  • Request22 20 0C
  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.375 − 48)
Range
-48 to 47.625 °
Unit
°

In testing for 2020 to 2026.

Timing angle retardation cylinder 4 CUPRA_TIMING_ANGLE_RETARDATION_CYL_4

  • Request22 20 0D
  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.375 − 48)
Range
-48 to 47.625 °
Unit
°

In testing for 2020 to 2026.

Timing deviation after chain replacement, exhaust bank 1 CUPRA_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Request22 41 7D
  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °
Unit
°

In testing for 2020 to 2026.

Timing deviation after chain replacement, intake bank 1 CUPRA_TIM_DEV_AFTER_CHAIN_1

  • Request22 41 7B
  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °
Unit
°

In testing for 2020 to 2026.

Timing deviation after other repairs, intake bank 1 CUPRA_TIM_DEV_AFTER_OTHER_1

  • Request22 41 7F
  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °
Unit
°

In testing for 2020 to 2026.

Timing deviation after other repairs, intake bank 1 CUPRA_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Request22 41 81
  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °
Unit
°

In testing for 2020 to 2026.

Timing deviation current value exhaust bank 1 CUPRA_TIM_DEV_CURRENT_EXH_1

  • Request22 41 85
  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °
Unit
°

In testing for 2020 to 2026.

Timing deviation current value intake bank 1 CUPRA_TIM_DEV_CURRENT_INT_1

  • Request22 41 83
  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °
Unit
°

In testing for 2020 to 2026.

Torque converter clutch status CUPRA_TC_STS

  • Request22 70 78
  • Service 22DID 7078
  • ModuleFC00 → FE0077
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 55)
Range
-55 to 200 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Torque converter slip CUPRA_TORQUE_CONVERTER_SLIP_FC00

  • Request22 21 31
  • Service 22DID 2131
  • ModuleFC00 → FE0077
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2020 to 2026.

Torque converter: torque loss CUPRA_TORQUE_CONVERTER_TORQUE_LOSS

  • Request22 70 53
  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Torque converter: torque loss CUPRA_TORQUE_CONVERTER_TORQUE_LOSS_V2

  • Request22 70 53
  • Service 22DID 7053
  • ModuleFC00 → FE0077
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque distribution CUPRA_TQ_DISTRIBUTION

  • Request22 2B 0A
  • Service 22DID 2B0A
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque factor CUPRA_TQ_FACTOR

  • Request22 21 19
  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Torque increase request from ESP CUPRA_TQ_INCREASE_REQ_ESP

  • Request22 13 40
  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque limit CUPRA_PQ35_LIM_TRQ

  • Request22 10 6B
  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Torque limitation CUPRA_TORQUE_LIMITATION

  • Request22 20 3F
  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Torque limitation CUPRA_TORQUE_LIMITATION_V2

  • Request22 20 3F
  • Service 22DID 203F
  • ModuleFC00 → FE0077
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque limitation CUPRA_TQ_LIM

  • Request22 10 7D
  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque limitation CUPRA_TQ_LIM_7E0

  • Request22 20 3F
  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque limitation, clutch protection CUPRA_TQ_LIM_CLU

  • Request22 20 A0
  • Service 22DID 20A0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque loss adaptation CUPRA_TQ_LOSS_ADPT

  • Request22 21 22
  • Service 22DID 2122
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque loss adaptation at idle CUPRA_TQ_LOSS_ADPT_IDLE

  • Request22 12 25
  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque loss adaptation, A/C compressor CUPRA_TQ_LOSS_ADPT_AC_COMP_7E0

  • Request22 12 23
  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque loss adaptation, A/C compressor CUPRA_TQ_LOSS_ADPT_AC_COMP_V2

  • Request22 12 23
  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque reduction due to exhaust temperature CUPRA_PQ35_TRQ_RED_EXH_T

  • Request22 10 E3
  • Service 22DID 10E3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10000)
Range
-3.2768 to 3.276
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Torque reduction request from ESP CUPRA_TQ_REDUCTION_REQ_ESP

  • Request22 13 3F
  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque request, sum of auxiliary aggregate CUPRA_TQ_REQ_SUM_AUXILIARY

  • Request22 20 9B
  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque transmitting function CUPRA_TQ_TRANSMITTING_V2

  • Request22 21 05
  • Service 22DID 2105
  • Module71D → 787
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 49 ÷ 6250)
Range
0 to 513
Unit
Number

In testing for 2020 to 2026.

Torque transmitting function, ratio CUPRA_TQ_TRANSMITTING

  • Request22 21 05
  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Number

In testing for 2020 to 2026.

Total mass of gasoline and ethyl alcohol in oil CUPRA_TOT_MASS_GASOLINE

  • Request22 17 13
  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.021333)
Range
0 to 1398.0581
Unit
Raw value

In testing for 2020 to 2026.

Transmission fluid temperature CUPRA_ATF_T_FC00

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 21 04
  • Service 22DID 2104
  • ModuleFC00 → FE0077
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Transmission fluid temperature, calculated CUPRA_ATF_T_CALCULATED

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 70 4E
  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Transmission fluid temperature, calculated CUPRA_ATF_T_CALCULATED_V2

  • Request22 70 4E
  • Service 22DID 704E
  • ModuleFC00 → FE0077
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

Transmission fluid temperature, dual-clutch CUPRA_ATF_T_DUAL_CLU

  • Request22 21 04
  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2020 to 2026.

Transmission fluid temperature, maximum reached CUPRA_ATF_T_MAX_REACHED

  • Request22 70 4F
  • Service 22DID 704F
  • ModuleFC00 → FE0077
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Transmission fluid temperature, modeled max reached CUPRA_ATF_T_MODELED_MAX_REACHED_V2

  • Request22 70 51
  • Service 22DID 7051
  • ModuleFC00 → FE0077
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 55)
Range
-55 to 200 °C
Unit
°C

In testing for 2020 to 2026.

Transmission fluid temperature, modeled maximum reached CUPRA_ATF_T_MODELED_MAX_REACHED

  • Request22 70 51
  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 55)
Range
-55 to 200 °C
Unit
°C

In testing for 2020, 2022 to 2025. Not supported for 2021, 2026.

Turbine actuator 1 bank 1 activation CUPRA_PQ35_TURB_ACT_1_B1

  • Request22 11 7E
  • Service 22DID 117E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Turbine actuator 1 bank 1: activation CUPRA_ACT

  • Request22 11 2C
  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2023. Supported for 2025 to 2026.

Upper adapted coupling point K1 from macro slip path adaptation CUPRA_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT

  • Request22 11 0B
  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5)
Range
0 to 1275 mA
Unit
mA

In testing for 2020 to 2026.

Upper adapted coupling point K2 from macro slip path adaptation CUPRA_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT

  • Request22 11 0C
  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5)
Range
0 to 1275 mA
Unit
mA

In testing for 2020 to 2026.

Valve lift system, result of last switch, intake CUPRA_VLV_LIFT_SYSTEM

  • Request22 16 BE
  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Valve lift system, valve lift, exhaust CUPRA_VLV_LIFT_SYSTEM_VLV_LIFT

  • Request22 16 BB
  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Valve lift system, valve lift, intake CUPRA_VLV_LIFT_SYSTEM_VLV

  • Request22 16 BA
  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Valve timing, the difference between the, actual and the set angle CUPRA_VLV_TIM_DIFF_ACT_SET

  • Request22 10 EC
  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °
Unit
°

In testing for 2020 to 2026.

Variable valve timing, intake, bank 1, regulation CUPRA_VARIABLE_VLV_TIM_INT_1

  • Request22 12 7B
  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0030517549)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Variable valve timing, intake, bank 1, switch on CUPRA_VARIABLE_VLV_TIM_INT_1_ON

  • Request22 12 7D
  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0030517549)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Washer nozzle heater active CUPRA_HTR_NOZZLE

  • Request22 19 45
  • Service 22DID 1945
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Wear index CUPRA_PQ35_WEAR_IDX

  • Request22 10 E2
  • Service 22DID 10E2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Wear index %, 0=new engine CUPRA_WEAR_INDEX_0_NEW_ENG

  • Request22 20 C2
  • Service 22DID 20C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine › DPF

Diesel particulate filter ash load limit CUPRA_MQB_DPF_ASH_LOAD_LIMIT

  • Request22 1A BF
  • Service 22DID 1ABF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 78.125 ÷ 10000)
Range
0 to 511.992
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter diff pressure: raw value 1 CUPRA_MQB_DPF_DIFF_P_RAW_VALUE_1

  • Request22 26 9A
  • Service 22DID 269A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter diff pressure: raw value 2 CUPRA_MQB_DPF_DIFF_P_RAW_VALUE_2

  • Request22 26 9B
  • Service 22DID 269B
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter field regeneration lock status CUPRA_DPF_FIELD_REGEN_LOCK

  • Request22 11 C1
  • Service 22DID 11C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter field regeneration request CUPRA_MQB_DPF_FIELD_REGEN_REQUEST

  • Request22 1A C2
  • Service 22DID 1AC2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter fuel consumption since last regeneration CUPRA_MQB_DPF_FUEL_CONSUMPTION_SINCE_LAST_REGEN

  • Request22 1A C1
  • Service 22DID 1AC1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 L
Unit
L

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter fuel consumption since last regeneration CUPRA_PQ35_DPF_FUEL_CON_REGEN

  • Request22 11 5A
  • Service 22DID 115A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 L
Unit
L

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter inlet lambda value CUPRA_MQB_DPF_INLET_LAMBDA_VALUE

  • Request22 1A D5
  • Service 22DID 1AD5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 10 ÷ 10000)
Range
-32.768 to 32.767
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter oil ash volume CUPRA_PQ35_DPF_OIL_ASH_VOL

  • Request22 11 53
  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every10.25 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 L
Unit
L

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Diesel particulate filter regeneration level current CUPRA_MQB_DPF_REGEN_LEVEL_I

  • Request22 1A D3
  • Service 22DID 1AD3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter regeneration release requirement CUPRA_MQB_DPF_REGEN_RELEASE_REQUIREMENT

  • Request22 1A D2
  • Service 22DID 1AD2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter regeneration status CUPRA_MQB_DPF_REGEN_STATUS

  • Request22 1A D4
  • Service 22DID 1AD4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter regeneration time counter CUPRA_MQB_DPF_REGEN_TIME_COUNTER

  • Request22 1A C0
  • Service 22DID 1AC0
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 6400 ÷ 10000)
Range
0 to 41942.4 s
Unit
s

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter service regeneration current duration CUPRA_MQB_DPF_SERVICE_REGEN_I_DURATION

  • Request22 1A C4
  • Service 22DID 1AC4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 6400 ÷ 10000)
Range
0 to 41942.4 s
Unit
s

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter soot mass measured CUPRA_MQB_DPF_SOOT_MASS_MEASURED

  • Request22 1A BE
  • Service 22DID 1ABE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics average drive cycle time during charge cycle CUPRA_MQB_DPF_STATISTICS_AVERAGE_DRIVE_CYCLE_TIME_DURING_CHARGE_CYCLE

  • Request22 1A CC
  • Service 22DID 1ACC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1600 ÷ 100)
Range
0 to 4080 s
Unit
s

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics error status CUPRA_MQB_DPF_STATISTICS_ERROR_STATUS

  • Request22 1A CA
  • Service 22DID 1ACA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics exhaust temperature regulation average value CUPRA_MQB_DPF_STATISTICS_EXHAUST_T_REGULATION_AVERAGE_VALUE

  • Request22 1A C7
  • Service 22DID 1AC7
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 1.98 ÷ 127)
Range
-1.99 to 1.98
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics number of interrupted regenerations CUPRA_MQB_DPF_STATISTICS_NUMBER_INTERRUPTED_REGENS

  • Request22 1A C9
  • Service 22DID 1AC9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics regeneration blocked status CUPRA_MQB_DPF_STATISTICS_REGEN_BLOCKED_STATUS

  • Request22 1A C8
  • Service 22DID 1AC8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics regeneration request CUPRA_MQB_DPF_STATISTICS_REGEN_REQUEST

  • Request22 1A C5
  • Service 22DID 1AC5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics regeneration time CUPRA_MQB_DPF_STATISTICS_REGEN_TIME

  • Request22 1A CD
  • Service 22DID 1ACD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 6400 ÷ 100)
Range
0 to 16320 s
Unit
s

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics regeneration time slice not possible in charge cycle CUPRA_MQB_DPF_STATISTICS_REGEN_TIME_SLICE_NOT_POSS_IN_CHARGE_CYCLE

  • Request22 1A CE
  • Service 22DID 1ACE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.498 ÷ 255)
Range
0 to 0.498
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter statistics route in charge cycle CUPRA_MQB_DPF_STATISTICS_ROUTE_IN_CHARGE_CYCLE

  • Request22 1A CB
  • Service 22DID 1ACB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 800 ÷ 100)
Range
0 to 2040 km
Unit
km

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter time since last regeneration CUPRA_MQB_DPF_TIME_SINCE_LAST_REGEN

  • Request22 1A C3
  • Service 22DID 1AC3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 127.998 ÷ 65535)
Range
0 to 127.998 h
Unit
h

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter unburned fuel calculated CUPRA_MQB_DPF_UNBURNED_FUEL_CALCULATED

  • Request22 18 BB
  • Service 22DID 18BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.768 to 32.767
Unit
Number

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter, charge limit for service regeneration while driving CUPRA_MQB_DPF_CHARGE_LIMIT_SERVICE_REGEN_WHILE_DRIVING

  • Request22 1A BB
  • Service 22DID 1ABB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter, charge limit over-charge CUPRA_MQB_DPF_CHARGE_LIMIT_OVER_CHARGE

  • Request22 1A BC
  • Service 22DID 1ABC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Diesel particulate filter, distance since last regeneration CUPRA_MQB_DPF_DISTANCE_SINCE_LAST_REGEN

  • Request22 1A BA
  • Service 22DID 1ABA
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 km
Unit
km

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Distance since last regeneration CUPRA_PQ35_DIST_LAST_REGEN

  • Request22 11 56
  • Service 22DID 1156
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Particulate filter soot mass calculated CUPRA_DPF_SOOT_MASS_CALCULATED

  • Request22 26 09
  • Service 22DID 2609
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020 to 2026.

Regeneration duration CUPRA_PQ35_REGEN_DUR

  • Request22 13 47
  • Service 22DID 1347
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Service regeneration status CUPRA_SRV_REGEN_STAT

  • Request22 11 5C
  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Soot index CUPRA_PQ35_SOOT_IDX

  • Request22 13 54
  • Service 22DID 1354
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Soot mass calculated CUPRA_PQ35_SOOT_MASS_CALC

  • Request22 11 4F
  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Soot mass measured CUPRA_SOOT_MASS_MEAS

  • Request22 11 4E
  • Service 22DID 114E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2020 to 2026.

Unidentified engine value, raw count CUPRA_ENG_114F_RAW

  • Request22 11 4F
  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Engine › EGR

Exhaust gas recirculation 2: filter press loss, modeled CUPRA_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED

  • Request22 2A E1
  • Service 22DID 2AE1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 500)
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Exhaust gas recirculation 2: filter press loss, simulated CUPRA_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED

  • Request22 2A E2
  • Service 22DID 2AE2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 500)
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

High press EGR closing v1 CUPRA_PQ35_HIGH_P_EGR_CLOSING_VAR_1

  • Request22 F4 69
  • Service 22DID F469
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

High press EGR closing v2 CUPRA_PQ35_HIGH_P_EGR_CLOSING_VAR_2

  • Request22 F4 2C
  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020, 2022. Not supported for 2021, 2023 to 2026.

Engine › Internal

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2023. Supported for 2025.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2023. Supported for 2025.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2024 to 2026.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2024 to 2026.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2024 to 2026.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2024 to 2026.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2024 to 2026.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2024 to 2026.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2024 to 2026.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2024 to 2026.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2021, 2023 to 2026.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Request01 15
  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2023. Supported for 2021, 2024 to 2026.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2023. Supported for 2021, 2024 to 2026.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2021, 2023 to 2026.

Engine › Water pump

Water pump power CUPRA_PTC_PUMP_PWR

  • Request22 27 D6
  • Service 22DID 27D6
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 40)
Range
0 to 10200
Unit
Raw value

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Water pump RPM CUPRA_PTC_PUMP_RPM

  • Request22 27 D6
  • Service 22DID 27D6
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 300)
Range
0 to 76500 rpm
Unit
rpm

In testing for 2022. Not supported for 2020 to 2021, 2023 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f