BMW M2

Battery parameters

The BMW M2 has 64 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Aging factor BMW_HVBAT_IMPEDANCE_ALPHA

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Aging factor BMW_HVBAT_IMPEDANCE_ALPHA

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Battery capacity BMW_BAT_CAP

  • Request22 40 A9
  • Service 22DID 40A9
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2016 to 2021, 2023 to 2026.

Battery state of charge current BMW_BAT_ST_CHG_CURRENT

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery state of charge last-1 BMW_BAT_ST_CHG_LAST_1

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery state of charge last-2 BMW_BAT_ST_CHG_LAST_2

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery state of charge last-3 BMW_BAT_ST_CHG_LAST_3

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery state of charge last-4 BMW_BAT_ST_CHG_LAST_4

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery state of charge last-5 BMW_BAT_ST_CHG_LAST_5

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery time in invalid state of charge BMW_BAT_TIME_INVALID_ST

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery time in state of charge 0-40% BMW_BAT_TIME_ST_CHG_0_40

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery time in state of charge 40-60% BMW_BAT_TIME_ST_CHG_40_60

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery time in state of charge 60-70% BMW_BAT_TIME_ST_CHG_60_70

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery time in state of charge 70-80% BMW_BAT_TIME_ST_CHG_70_80

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery time in state of charge 80-90% BMW_BAT_TIME_ST_CHG_80_90

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery time in state of charge 90-100% BMW_BAT_TIME_ST_CHG_90_100

  • Request22 40 AD
  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021, 2023 to 2026.

Battery voltage BMW_BAT_V

  • Request22 E5 4D
  • Service 22DID E54D
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2016 to 2021, 2023 to 2026.

Cell capacity, average BMW_HVBAT_C_CAP_AVG

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell capacity, max BMW_HVBAT_C_CAP_MAX

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell capacity, min BMW_HVBAT_C_CAP_MIN

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell OCV, average BMW_HVBAT_C_OCV_AVG

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535 V
Unit
V

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell OCV, max BMW_HVBAT_C_OCV_MAX

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535 V
Unit
V

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell OCV, min BMW_HVBAT_C_OCV_MIN

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535 V
Unit
V

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell resistance factor, average BMW_HVBAT_C_RES_FACTOR_AVG

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell resistance factor, max BMW_HVBAT_C_RES_FACTOR_MAX

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell resistance factor, min BMW_HVBAT_C_RES_FACTOR_MIN

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell state of charge, average BMW_HVBAT_C_SOC_AVG

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell state of charge, max BMW_HVBAT_C_SOC_MAX

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell state of charge, min BMW_HVBAT_C_SOC_MIN

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell temperature, average BMW_HVBAT_C_TEMP_AVG

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell temperature, max BMW_HVBAT_C_TEMP_MAX

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell temperature, min BMW_HVBAT_C_TEMP_MIN

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell voltage, average BMW_HVBAT_C_V_AVG

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535 V
Unit
V

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell voltage, max BMW_HVBAT_C_V_MAX

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535 V
Unit
V

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Cell voltage, min BMW_HVBAT_C_V_MIN

  • Request22 DF A0
  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.5535 V
Unit
V

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Charge port light state BMW_CHG_LED

  • Request22 DE F3
  • Service 22DID DEF3
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021, 2023 to 2026.

Charging interface ready BMW_CHG_READY

  • Request22 DE F2
  • Service 22DID DEF2
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2021, 2023 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2024. Supported for 2016 to 2020, 2023, 2025.

DC charge contactor state BMW_DC_CONTACTOR

  • Request22 DE F8
  • Service 22DID DEF8
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021, 2023 to 2026.

DC charge control 1 BMW_DC_CTRL_1

  • Request22 DE F7
  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2021, 2023 to 2026.

DC charge control 2 BMW_DC_CTRL_2

  • Request22 DE F7
  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2021, 2023 to 2026.

DC charge permission BMW_DC_PERMIT

  • Request22 DE F7
  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2021, 2023 to 2026.

DC charge plug connected BMW_DC_PLUG

  • Request22 DE F7
  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2021, 2023 to 2026.

High voltage battery current BMW_HVBAT_CURRENT

  • Request22 E5 61
  • Service 22DID E561
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val × -1 ÷ 100)
Range
-327 to 327 A
Unit
A

In testing for 2016 to 2021, 2023 to 2026.

HV battery cell temperature, max BMW_HVBAT_CT_MAX

  • Request22 DD C0
  • Service 22DID DDC0
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.67 to 327.67 °C
Unit
°C

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery cell temperature, min BMW_HVBAT_CT_MIN

  • Request22 DD C0
  • Service 22DID DDC0
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.67 to 327.67 °C
Unit
°C

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery charge BMW_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Request22 DD BC
  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery charge BMW_HVBAT_SOC_V2

Pelican can show this parameter as the state of charge.

  • Request22 E5 CE
  • Service 22DID E5CE
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery charge, max BMW_HVBAT_SOC_MAX

  • Request22 DD BC
  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery charge, min BMW_HVBAT_SOC_MIN

  • Request22 DD BC
  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery current BMW_HVBAT_C

Pelican can show this parameter as the traction battery current.

  • Request22 DD 69
  • Service 22DID DD69
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 100)
Range
-10000 to 10000 A
Unit
A

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery current BMW_HVBAT_CURR

  • Request22 DD 69
  • Service 22DID DD69
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 100)
Range
-10000 to 10000 A
Unit
A

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery health BMW_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Request22 63 35
  • Service 22DID 6335
  • Module6F1 → 607
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018, 2020 to 2021, 2026. Not supported for 2016 to 2017, 2019, 2023 to 2025.

HV battery health BMW_HVBAT_SOH_V2

Pelican can show this parameter as the state of health.

  • Request22 E5 C7
  • Service 22DID E5C7
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

HV battery voltage BMW_HVBAT_VOLT

  • Request22 DD 68
  • Service 22DID DD68
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 2016 to 2021, 2023 to 2026.

Is charger connected BMW_HVBAT_CHG_CON

Pelican can show this parameter as the plug state.

  • Request22 DE 00
  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Is charging BMW_HVBAT_CHG_CON_EXT

Pelican can show this parameter as the charging state.

  • Request22 DE 00
  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Minimum state of charge BMW_HVBAT_HVPM_MIN_SOC

  • Request22 DE 00
  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Number of cells BMW_HVBAT_C_CNT

  • Request22 DF 71
  • Service 22DID DF71
  • Module6F1 → 607
  • Every86400 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Number of cells per module BMW_HVBAT_C_CNT_MOD

  • Request22 DF 71
  • Service 22DID DF71
  • Module6F1 → 607
  • Every86400 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Number of modules BMW_HVBAT_MOD_CNT

  • Request22 DF 71
  • Service 22DID DF71
  • Module6F1 → 607
  • Every86400 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Number of temperature sensors per module BMW_HVBAT_MOD_T_CNT

  • Request22 DF 71
  • Service 22DID DF71
  • Module6F1 → 607
  • Every86400 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Original battery capacity BMW_ORIGINAL_BAT_CAP

  • Request22 40 A9
  • Service 22DID 40A9
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2016 to 2021, 2023 to 2026.

Ready to drive BMW_HVBAT_CHG_RDY

  • Request22 DE 00
  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

State of charge, power module BMW_HVBAT_HVPM_SOC

Battery level reading from the high voltage power module

  • Request22 DE 00
  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

In testing for 2016, 2018, 2020 to 2021, 2026. Not supported for 2017, 2019, 2023 to 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.