DTC parameters
The Audi Q4 e-tron has 48 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
Pelican can show this parameter as the checkEngineLightOn.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022 to 2025. Supported for 2021.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
Pelican can show this parameter as the storedDTCCount.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2022 to 2025. Supported for 2021.
DTCs › Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022 to 2025. Supported for 2021.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022 to 2025. Supported for 2021.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022 to 2025. Supported for 2021.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2021, 2024.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
DTCs › Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2022 to 2025. Supported for 2021.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2025. Supported for 2021, 2024.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2021, 2024.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022 to 2025. Supported for 2021.