Battery parameters
The Audi Q4 e-tron has 221 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery adapted capacity Q4ETRON_AUX_BAT_CAPConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 176 to 183 of the reply, 8 bits.
0x2E = 46 → 46 Ah
- Formula
val- Range
- 0 to 100 Ah
- Unit
- Ah
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
12V battery aging by capacity Q4ETRON_AUX_BAT_AGE_CAPConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 160 to 167 of the reply, 8 bits.
0x5E = 94 → 94 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
12V battery aging by power Q4ETRON_AUX_BAT_AGE_POWConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 168 to 175 of the reply, 8 bits.
0x5E = 94 → 94 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
12V battery current Q4ETRON_AUX_BAT_CConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 16 to 47 of the reply, 32 bits. The value is signed.
0x00000578 = 1400 → (1400 ÷ 1000) = 1.4 A
- Formula
(val ÷ 1000)- Range
- -1000000 to 1000000 A
- Unit
- A
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
12V battery soc Q4ETRON_AUX_BAT_SOCConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 56 to 63 of the reply, 8 bits.
0x5F = 95 → 95 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
12V battery total charge Q4ETRON_AUX_BAT_CHRG_TOTConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 96 to 127 of the reply, 32 bits.
0x00002728 = 10024 → (10024 ÷ 10) = 1,002.4 Ah
- Formula
(val ÷ 10)- Range
- 0 to 10000000 Ah
- Unit
- Ah
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
12V battery total discharge Q4ETRON_AUX_BAT_DSCH_TOTConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 128 to 159 of the reply, 32 bits.
0x000024D1 = 9425 → (9425 ÷ 10) = 942.5 Ah
- Formula
(val ÷ 10)- Range
- 0 to 10000000 Ah
- Unit
- Ah
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
12V battery voltage Q4ETRON_AUX_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 0 to 15 of the reply, 16 bits.
0x2399 = 9113 → (9113 ÷ 1000 + 4) = 13.113 V
- Formula
(val ÷ 1000 + 4)- Range
- 0 to 69 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
AC charging Q4ETRON_AC_CHARGINGConfirmed
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Average battery consumption Q4ETRON_HVBAT_CSMP_AVG_INTConfirmed
- Request
22 2A B4 - Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 72 to 79 of the reply, 8 bits.
0x2E = 46 → 46 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery cell soc max, ID Q4ETRON_HVBAT_CELL_SOC_MAX_IDConfirmed
- Request
22 1E 2C - Service 22
DID 1E2C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery cell soc min, ID Q4ETRON_HVBAT_CELL_SOC_MIN_IDConfirmed
- Request
22 1E 2D - Service 22
DID 1E2D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery cell soc, maximum Q4ETRON_HVBAT_CELL_SOC_MAXConfirmed
- Request
22 1E 2C - Service 22
DID 1E2C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery cell soc, minimum Q4ETRON_HVBAT_CELL_SOC_MINConfirmed
- Request
22 1E 2D - Service 22
DID 1E2D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery current limit, charging Q4ETRON_HVBAT_I_LIM_CHGConfirmed
- Request
22 1E 1B - Service 22
DID 1E1B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 2621.4 A
- Unit
- A
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery current limit, discharging Q4ETRON_HVBAT_I_LIM_DSCHConfirmed
- Request
22 1E 1C - Service 22
DID 1E1C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 2621.4 A
- Unit
- A
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery current, DC, second read Q4ETRON_HVBAT_I_DC_2Confirmed
- Request
22 1E 3E - Service 22
DID 1E3E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100 − 1500)- Range
- -1500 to 42948172.95 A
- Unit
- A
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery current, motor controller Q4ETRON_HVBAT_I_ENGConfirmed
- Request
22 03 5E - Service 22
DID 035E - Module
FC00 → FE0076 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2024. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021.
Battery heater current Q4ETRON_HVBAT_PTC_IConfirmed
- Request
22 16 20 - Service 22
DID 1620 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 A
- Unit
- A
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery heater temperature, #1 Q4ETRON_HVBAT_PTC_T_1Confirmed
- Request
22 16 23 - Service 22
DID 1623 - Module
FC00 → FE007B - Every
5 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery heater temperature, #2 Q4ETRON_HVBAT_PTC_T_2Confirmed
- Request
22 16 24 - Service 22
DID 1624 - Module
FC00 → FE007B - Every
5 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery heater voltage Q4ETRON_HVBAT_PTC_VConfirmed
- Request
22 16 21 - Service 22
DID 1621 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery temperature, inlet Q4ETRON_HVBAT_T_INConfirmed
- Request
22 18 9D - Service 22
DID 189D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery temperature, max Q4ETRON_HVBAT_T_MAXConfirmed
- Request
22 1E 0E - Service 22
DID 1E0E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery temperature, max sensor ID Q4ETRON_HVBAT_T_MAX_IDConfirmed
- Request
22 1E 0E - Service 22
DID 1E0E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery temperature, min Q4ETRON_HVBAT_T_MINConfirmed
- Request
22 1E 0F - Service 22
DID 1E0F - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery temperature, min sensor ID Q4ETRON_HVBAT_T_MIN_IDConfirmed
- Request
22 1E 0F - Service 22
DID 1E0F - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery temperature, outlet Q4ETRON_HVBAT_T_OUTConfirmed
- Request
22 18 9D - Service 22
DID 189D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery voltage, after main switch Q4ETRON_HVBAT_V_AFTERConfirmed
- Request
22 1E 38 - Service 22
DID 1E38 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 312499785 ÷ 10000000000)- Range
- 0 to 2047.967 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery voltage, before main switch Q4ETRON_HVBAT_V_BEFOREConfirmed
- Request
22 1E 36 - Service 22
DID 1E36 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 312499785 ÷ 10000000000)- Range
- 0 to 2047.967 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery voltage, charging Q4ETRON_HVBAT_V_CHGConfirmed
- Request
22 1E 39 - Service 22
DID 1E39 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 312499785 ÷ 10000000000)- Range
- -1023.999 to 1023.967 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery voltage, sum of all cells Q4ETRON_HVBAT_V_CELLS_SUMConfirmed
- Request
22 1E 3C - Service 22
DID 1E3C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val × 244140625 ÷ 1000000000)- Range
- -524288 to 524287.99 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery voltage, traction mode Q4ETRON_HVBAT_V_TRACConfirmed
- Request
22 46 75 - Service 22
DID 4675 - Module
FC00 → FE0076 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 V
- Unit
- V
Confirmed for 2024. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021.
Charge voltage, max Q4ETRON_MAXIMUM_CHARGE_VConfirmed
- Request
22 51 71 - Service 22
DID 5171 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Charger coolant temperature Q4ETRON_CHRGR_COOLANT_TConfirmed
- Request
22 15 E2 - Service 22
DID 15E2 - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 0 to 7 of the reply, 8 bits.
0x39 = 57 → (57 − 40) = 17 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Charging duration total Q4ETRON_CHRGR_DUR_TOTALConfirmed
- Request
22 15 EE - Service 22
DID 15EE - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 0 to 31 of the reply, 32 bits.
0x0003560A = 218634 → 218,634 min
- Formula
val- Range
- 0 to 4294967295 min
- Unit
- min
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Charging, rapid? Q4ETRON_RAPID_CHARGE_PORTConfirmed
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Control module temperature Q4ETRON_HVBAT_ECU_TConfirmed
- Request
22 16 22 - Service 22
DID 1622 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2024 to 2025. Supported for 2021.
Current gear Q4ETRON_DRIVE_MODEConfirmed
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bit 7 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STANDBY | Standby |
1 | DRIVING | Driving |
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Cycle energy transformation Q4ETRON_OBC_CYCLE_ENERGYConfirmed
- Request
22 10 3E - Service 22
DID 103E - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0 kWh
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
DC battery voltage Q4ETRON_DC_BATTERY_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 1E 3B - Service 22
DID 1E3B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
DC link voltage Q4ETRON_DC_LINK_V
- Request
22 3E 93 - Service 22
DID 3E93 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 V
- Unit
- V
In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
DC link voltage reserve Q4ETRON_DC_LINK_V_RESERVE
- Request
22 43 B9 - Service 22
DID 43B9 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 V
- Unit
- V
In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
DC-DC converter coolant temperature Q4ETRON_DCDC_T_COOLConfirmed
- Request
22 43 B8 - Service 22
DID 43B8 - Module
FC00 → FE0076 - Every
5 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
Confirmed for 2024. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021.
DC-DC converter current, alternate Q4ETRON_DCDC_I_ALTConfirmed
- Request
22 46 5B - Service 22
DID 465B - Module
FC00 → FE00B9 - Every
1 s - Testing for 2022 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 A
- Unit
- A
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
DC-DC converter, current Q4ETRON_DCDC_IConfirmed
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 8 to 23 of the reply, 16 bits.
0x020A = 522 → (522 − 511) = 11 A
- Formula
(val − 511)- Range
- -511 to 65024 A
- Unit
- A
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
DC-DC converter, low voltage Q4ETRON_DCDC_V_LOWConfirmed
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 0 to 7 of the reply, 8 bits.
0x84 = 132 → (132 ÷ 10) = 13.2 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
DC-DC converter, reserved current Q4ETRON_DCDC_I_RSVConfirmed
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 24 to 39 of the reply, 16 bits.
0x02BC = 700 → (700 − 511) = 189 A
- Formula
(val − 511)- Range
- -511 to 65024 A
- Unit
- A
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
DC-DC voltage Q4ETRON_DC_DC_VConfirmed
- Request
22 46 5D - Service 22
DID 465D - Module
FC00 → FE00B9 - Every
1 s - Testing for 2022 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.9980469 V
- Unit
- V
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Desired link voltage Q4ETRON_DESIRED_LINK_V
- Request
22 3E ED - Service 22
DID 3EED - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 V
- Unit
- V
In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Discharge voltage, min Q4ETRON_MINIMUM_DISCHARGE_VConfirmed
- Request
22 51 70 - Service 22
DID 5170 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Electric motor battery energy Q4ETRON_HV_EM_HVBAT_ENERGY_INFORMATIONConfirmed
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 40 to 55 of the reply, 16 bits.
0x02DE = 734 → (734 × 50 ÷ 1000) = 36.7 kWh
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 3276.75 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Supported for 2024.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 1 to 2 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
Confirmed for 2024 to 2025. Supported for 2021.
Estimated electric power reserve Q4ETRON_RANGE_RESERVE_ESTConfirmed
- Request
22 2A B4 - Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 16 to 31 of the reply, 16 bits.
0x008C = 140 → 140 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Estimated reserve range Q4ETRON_RANGE_EST_CANConfirmed
- Request
22 2A B5 - Service 22
DID 2AB5 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 32 to 47 of the reply, 16 bits.
0x008C = 140 → 140 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
High voltage output Q4ETRON_OBC_HIGH_V_OUTPUTConfirmed
- Request
22 1D A7 - Service 22
DID 1DA7 - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 0 to 15 of the reply, 16 bits.
0x0D99 = 3481 → (3481 ÷ 10) = 348.1 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
HV auxiliary current total Q4ETRON_HVAUX_IConfirmed
- Request
22 03 60 - Service 22
DID 0360 - Module
FC00 → FE0076 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2024. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021.
HV auxiliary power Q4ETRON_HVAUX_PWRConfirmed
- Request
22 03 64 - Service 22
DID 0364 - Module
FC00 → FE0076 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 kW
- Unit
- kW
Confirmed for 2024. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021.
HV battery after contacts voltage Q4ETRON_HVBAT_AFTER_CONTACTS_VConfirmed
- Request
22 18 9B - Service 22
DID 189B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 1000)- Range
- -1000 to 31767.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage max, ID Q4ETRON_HVBAT_CELL_V_MAX_IDConfirmed
- Request
22 1E 33 - Service 22
DID 1E33 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage min, ID Q4ETRON_HVBAT_CELL_V_MIN_IDConfirmed
- Request
22 1E 34 - Service 22
DID 1E34 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, maximum Q4ETRON_HVBAT_CELL_V_MAXConfirmed
- Request
22 1E 33 - Service 22
DID 1E33 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2441 ÷ 10000)- Range
- 0 to 15.997 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, minimum Q4ETRON_HVBAT_CELL_V_MINConfirmed
- Request
22 1E 34 - Service 22
DID 1E34 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2441 ÷ 10000)- Range
- 0 to 15.997 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery energy Q4ETRON_HVBAT_KWHConfirmed
Energy stored in the high voltage battery
- Request
22 2A B8 - Service 22
DID 2AB8 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 16 to 31 of the reply, 16 bits.
0x03C2 = 962 → (962 × 25 ÷ 1000) = 24.05 kWh
- Formula
(val × 25 ÷ 1000)- Range
- 0 to 1638 kWh
- Unit
- kWh
Confirmed for 2021, 2024. In testing for 2023, 2025 to 2026. Not supported for 2022.
HV battery module temperature, #1 Q4ETRON_HVBAT_MOD_T_1Confirmed
- Request
22 1E AE - Service 22
DID 1EAE - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #2 Q4ETRON_HVBAT_MOD_T_2Confirmed
- Request
22 1E AF - Service 22
DID 1EAF - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #3 Q4ETRON_HVBAT_MOD_T_3Confirmed
- Request
22 1E B0 - Service 22
DID 1EB0 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #4 Q4ETRON_HVBAT_MOD_T_4Confirmed
- Request
22 1E B1 - Service 22
DID 1EB1 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #17 Q4ETRON_HVBAT_MOD_T_17Confirmed
- Request
22 74 25 - Service 22
DID 7425 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #18 Q4ETRON_HVBAT_MOD_T_18Confirmed
- Request
22 74 26 - Service 22
DID 7426 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #19 Q4ETRON_HVBAT_MOD_T_19Confirmed
- Request
22 74 27 - Service 22
DID 7427 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #20 Q4ETRON_HVBAT_MOD_T_20Confirmed
- Request
22 74 28 - Service 22
DID 7428 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #21 Q4ETRON_HVBAT_MOD_T_21Confirmed
- Request
22 74 29 - Service 22
DID 7429 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #22 Q4ETRON_HVBAT_MOD_T_22Confirmed
- Request
22 74 2A - Service 22
DID 742A - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #23 Q4ETRON_HVBAT_MOD_T_23Confirmed
- Request
22 74 2B - Service 22
DID 742B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #24 Q4ETRON_HVBAT_MOD_T_24Confirmed
- Request
22 74 2C - Service 22
DID 742C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery, max energy Q4ETRON_HVBAT_CAPConfirmed
- Request
22 2A B2 - Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 0 to 15 of the reply, 16 bits.
0x05CD = 1485 → (1485 × 50 ÷ 1000) = 74.25 kWh
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 3276.75 kWh
- Unit
- kWh
Confirmed for 2021, 2024. In testing for 2023, 2025 to 2026. Not supported for 2022.
HV battery: circulation pump flow Q4ETRON_CIRC_PUMP_FLOWConfirmed
- Request
22 74 3B - Service 22
DID 743B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Request
01 5B - Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2021.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2024 to 2025. Supported for 2021.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2024 to 2025. Supported for 2021.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2024 to 2025. Supported for 2021.
Non-vehicle energy requirement Q4ETRON_NV_ENERGY_REQUIREMENTConfirmed
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 32 to 39 of the reply, 8 bits.
0x33 = 51 → (51 × 50 ÷ 1000) = 2.55 kWh
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 12.75 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Supported for 2024.
On-board charger, hv/dc current Q4ETRON_OBC_HVDC_CConfirmed
- Request
22 10 3D - Service 22
DID 103D - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Power efficiency Q4ETRON_CHRGR_EFFICIENCYConfirmed
- Request
22 15 D6 - Service 22
DID 15D6 - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 10 + 75) = 75 A
- Formula
(val ÷ 10 + 75)- Range
- 75 to 100.5 A
- Unit
- A
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Rail 1 energy transformation Q4ETRON_CHRGR_RAIL1_EConfirmed
- Request
22 15 07 - Service 22
DID 1507 - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 0 to 23 of the reply, 24 bits.
0x007E82 = 32386 → (32386 ÷ 10) = 3,238.6 kWh
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Rail 2 energy transformation Q4ETRON_CHRGR_RAIL2_EConfirmed
- Request
22 15 07 - Service 22
DID 1507 - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 24 to 47 of the reply, 24 bits.
0x007C74 = 31860 → (31860 ÷ 10) = 3,186 kWh
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Rail 3 energy transformation Q4ETRON_CHRGR_RAIL3_EConfirmed
- Request
22 15 07 - Service 22
DID 1507 - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 48 to 71 of the reply, 24 bits.
0x007C52 = 31826 → (31826 ÷ 10) = 3,182.6 kWh
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Start/stop battery resistance Q4ETRON_SSB_RConfirmed
- Request
22 2A 0E - Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 2 ÷ 10) = 0 mΩ
- Formula
(val × 2 ÷ 10)- Range
- 0 to 51 mΩ
- Unit
- mΩ
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
State of charge Q4ETRON_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
FC00 - Every
250 ms - Testing for 2021 to 2022, 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 250)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025. In testing for 2026. Not supported for 2021 to 2022, 2024.
State of charge Q4ETRON_SOC_FC00Confirmed
Pelican can show this parameter as the state of charge.
- Request
22 3D EF - Service 22
DID 3DEF - Module
FC00 → FE0076 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2021.
Temperature sensor, socket a Q4ETRON_OBC_T_AConfirmed
- Request
22 1D DA - Service 22
DID 1DDA - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 8 to 23 of the reply, 16 bits.
0x0352 = 850 → (850 ÷ 10 − 55) = 30 °C
- Formula
(val ÷ 10 − 55)- Range
- -55 to 6498.5 °C
- Unit
- °C
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Temperature, 12V battery Q4ETRON_AUX_BAT_TConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 64 to 71 of the reply, 8 bits.
0x3B = 59 → (59 − 40) = 19 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Temperature, 12V battery sensor Q4ETRON_AUX_BAT_T_SConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Example reply from a 2024 Audi Q4 e-tron.
Bits 72 to 79 of the reply, 8 bits.
0x3A = 58 → (58 − 40) = 18 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Temperature, battery Q4ETRON_BATTERY_TConfirmed
- Request
22 2A 0B - Service 22
DID 2A0B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Voltage proximity, socket a Q4ETRON_OBC_V_PROX_AConfirmed
- Request
22 15 25 - Service 22
DID 1525 - Module
744 → 7AE - Every
1 s - Testing for 2022 to 2026
Example reply from a 2021 Audi Q4 e-tron.
Bits 0 to 15 of the reply, 16 bits.
0x1236 = 4662 → 4,662 mV
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
Confirmed for 2021. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Cells
HV battery cell voltage, #1 Q4ETRON_HVBAT_CELL_V_001Confirmed
- Request
22 1E 40 - Service 22
DID 1E40 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #2 Q4ETRON_HVBAT_CELL_V_002Confirmed
- Request
22 1E 41 - Service 22
DID 1E41 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #3 Q4ETRON_HVBAT_CELL_V_003Confirmed
- Request
22 1E 42 - Service 22
DID 1E42 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #4 Q4ETRON_HVBAT_CELL_V_004Confirmed
- Request
22 1E 43 - Service 22
DID 1E43 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #5 Q4ETRON_HVBAT_CELL_V_005Confirmed
- Request
22 1E 44 - Service 22
DID 1E44 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #6 Q4ETRON_HVBAT_CELL_V_006Confirmed
- Request
22 1E 45 - Service 22
DID 1E45 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #7 Q4ETRON_HVBAT_CELL_V_007Confirmed
- Request
22 1E 46 - Service 22
DID 1E46 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #8 Q4ETRON_HVBAT_CELL_V_008Confirmed
- Request
22 1E 47 - Service 22
DID 1E47 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #9 Q4ETRON_HVBAT_CELL_V_009Confirmed
- Request
22 1E 48 - Service 22
DID 1E48 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #10 Q4ETRON_HVBAT_CELL_V_010Confirmed
- Request
22 1E 49 - Service 22
DID 1E49 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #11 Q4ETRON_HVBAT_CELL_V_011Confirmed
- Request
22 1E 4A - Service 22
DID 1E4A - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #12 Q4ETRON_HVBAT_CELL_V_012Confirmed
- Request
22 1E 4B - Service 22
DID 1E4B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #13 Q4ETRON_HVBAT_CELL_V_013Confirmed
- Request
22 1E 4C - Service 22
DID 1E4C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #14 Q4ETRON_HVBAT_CELL_V_014Confirmed
- Request
22 1E 4D - Service 22
DID 1E4D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #15 Q4ETRON_HVBAT_CELL_V_015Confirmed
- Request
22 1E 4E - Service 22
DID 1E4E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #16 Q4ETRON_HVBAT_CELL_V_016Confirmed
- Request
22 1E 4F - Service 22
DID 1E4F - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #17 Q4ETRON_HVBAT_CELL_V_017Confirmed
- Request
22 1E 50 - Service 22
DID 1E50 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #18 Q4ETRON_HVBAT_CELL_V_018Confirmed
- Request
22 1E 51 - Service 22
DID 1E51 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #19 Q4ETRON_HVBAT_CELL_V_019Confirmed
- Request
22 1E 52 - Service 22
DID 1E52 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #20 Q4ETRON_HVBAT_CELL_V_020Confirmed
- Request
22 1E 53 - Service 22
DID 1E53 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #21 Q4ETRON_HVBAT_CELL_V_021Confirmed
- Request
22 1E 54 - Service 22
DID 1E54 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #22 Q4ETRON_HVBAT_CELL_V_022Confirmed
- Request
22 1E 55 - Service 22
DID 1E55 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #23 Q4ETRON_HVBAT_CELL_V_023Confirmed
- Request
22 1E 56 - Service 22
DID 1E56 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #24 Q4ETRON_HVBAT_CELL_V_024Confirmed
- Request
22 1E 57 - Service 22
DID 1E57 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #25 Q4ETRON_HVBAT_CELL_V_025Confirmed
- Request
22 1E 58 - Service 22
DID 1E58 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #26 Q4ETRON_HVBAT_CELL_V_026Confirmed
- Request
22 1E 59 - Service 22
DID 1E59 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #27 Q4ETRON_HVBAT_CELL_V_027Confirmed
- Request
22 1E 5A - Service 22
DID 1E5A - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #28 Q4ETRON_HVBAT_CELL_V_028Confirmed
- Request
22 1E 5B - Service 22
DID 1E5B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #29 Q4ETRON_HVBAT_CELL_V_029Confirmed
- Request
22 1E 5C - Service 22
DID 1E5C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #30 Q4ETRON_HVBAT_CELL_V_030Confirmed
- Request
22 1E 5D - Service 22
DID 1E5D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #31 Q4ETRON_HVBAT_CELL_V_031Confirmed
- Request
22 1E 5E - Service 22
DID 1E5E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #32 Q4ETRON_HVBAT_CELL_V_032Confirmed
- Request
22 1E 5F - Service 22
DID 1E5F - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #33 Q4ETRON_HVBAT_CELL_V_033Confirmed
- Request
22 1E 60 - Service 22
DID 1E60 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #34 Q4ETRON_HVBAT_CELL_V_034Confirmed
- Request
22 1E 61 - Service 22
DID 1E61 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #35 Q4ETRON_HVBAT_CELL_V_035Confirmed
- Request
22 1E 62 - Service 22
DID 1E62 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #36 Q4ETRON_HVBAT_CELL_V_036Confirmed
- Request
22 1E 63 - Service 22
DID 1E63 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #37 Q4ETRON_HVBAT_CELL_V_037Confirmed
- Request
22 1E 64 - Service 22
DID 1E64 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #38 Q4ETRON_HVBAT_CELL_V_038Confirmed
- Request
22 1E 65 - Service 22
DID 1E65 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #39 Q4ETRON_HVBAT_CELL_V_039Confirmed
- Request
22 1E 66 - Service 22
DID 1E66 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #40 Q4ETRON_HVBAT_CELL_V_040Confirmed
- Request
22 1E 67 - Service 22
DID 1E67 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #41 Q4ETRON_HVBAT_CELL_V_041Confirmed
- Request
22 1E 68 - Service 22
DID 1E68 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #42 Q4ETRON_HVBAT_CELL_V_042Confirmed
- Request
22 1E 69 - Service 22
DID 1E69 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #43 Q4ETRON_HVBAT_CELL_V_043Confirmed
- Request
22 1E 6A - Service 22
DID 1E6A - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #44 Q4ETRON_HVBAT_CELL_V_044Confirmed
- Request
22 1E 6B - Service 22
DID 1E6B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #45 Q4ETRON_HVBAT_CELL_V_045Confirmed
- Request
22 1E 6C - Service 22
DID 1E6C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #46 Q4ETRON_HVBAT_CELL_V_046Confirmed
- Request
22 1E 6D - Service 22
DID 1E6D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #47 Q4ETRON_HVBAT_CELL_V_047Confirmed
- Request
22 1E 6E - Service 22
DID 1E6E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #48 Q4ETRON_HVBAT_CELL_V_048Confirmed
- Request
22 1E 6F - Service 22
DID 1E6F - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #49 Q4ETRON_HVBAT_CELL_V_049Confirmed
- Request
22 1E 70 - Service 22
DID 1E70 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #50 Q4ETRON_HVBAT_CELL_V_050Confirmed
- Request
22 1E 71 - Service 22
DID 1E71 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #51 Q4ETRON_HVBAT_CELL_V_051Confirmed
- Request
22 1E 72 - Service 22
DID 1E72 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #52 Q4ETRON_HVBAT_CELL_V_052Confirmed
- Request
22 1E 73 - Service 22
DID 1E73 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #53 Q4ETRON_HVBAT_CELL_V_053Confirmed
- Request
22 1E 74 - Service 22
DID 1E74 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #54 Q4ETRON_HVBAT_CELL_V_054Confirmed
- Request
22 1E 75 - Service 22
DID 1E75 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #55 Q4ETRON_HVBAT_CELL_V_055Confirmed
- Request
22 1E 76 - Service 22
DID 1E76 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #56 Q4ETRON_HVBAT_CELL_V_056Confirmed
- Request
22 1E 77 - Service 22
DID 1E77 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #57 Q4ETRON_HVBAT_CELL_V_057Confirmed
- Request
22 1E 78 - Service 22
DID 1E78 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #58 Q4ETRON_HVBAT_CELL_V_058Confirmed
- Request
22 1E 79 - Service 22
DID 1E79 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #59 Q4ETRON_HVBAT_CELL_V_059Confirmed
- Request
22 1E 7A - Service 22
DID 1E7A - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #60 Q4ETRON_HVBAT_CELL_V_060Confirmed
- Request
22 1E 7B - Service 22
DID 1E7B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #61 Q4ETRON_HVBAT_CELL_V_061Confirmed
- Request
22 1E 7C - Service 22
DID 1E7C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #62 Q4ETRON_HVBAT_CELL_V_062Confirmed
- Request
22 1E 7D - Service 22
DID 1E7D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #63 Q4ETRON_HVBAT_CELL_V_063Confirmed
- Request
22 1E 7E - Service 22
DID 1E7E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #64 Q4ETRON_HVBAT_CELL_V_064Confirmed
- Request
22 1E 7F - Service 22
DID 1E7F - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #65 Q4ETRON_HVBAT_CELL_V_065Confirmed
- Request
22 1E 80 - Service 22
DID 1E80 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #66 Q4ETRON_HVBAT_CELL_V_066Confirmed
- Request
22 1E 81 - Service 22
DID 1E81 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #67 Q4ETRON_HVBAT_CELL_V_067Confirmed
- Request
22 1E 82 - Service 22
DID 1E82 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #68 Q4ETRON_HVBAT_CELL_V_068Confirmed
- Request
22 1E 83 - Service 22
DID 1E83 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #69 Q4ETRON_HVBAT_CELL_V_069Confirmed
- Request
22 1E 84 - Service 22
DID 1E84 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #70 Q4ETRON_HVBAT_CELL_V_070Confirmed
- Request
22 1E 85 - Service 22
DID 1E85 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #71 Q4ETRON_HVBAT_CELL_V_071Confirmed
- Request
22 1E 86 - Service 22
DID 1E86 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #72 Q4ETRON_HVBAT_CELL_V_072Confirmed
- Request
22 1E 87 - Service 22
DID 1E87 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #73 Q4ETRON_HVBAT_CELL_V_073Confirmed
- Request
22 1E 88 - Service 22
DID 1E88 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #74 Q4ETRON_HVBAT_CELL_V_074Confirmed
- Request
22 1E 89 - Service 22
DID 1E89 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #75 Q4ETRON_HVBAT_CELL_V_075Confirmed
- Request
22 1E 8A - Service 22
DID 1E8A - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #76 Q4ETRON_HVBAT_CELL_V_076Confirmed
- Request
22 1E 8B - Service 22
DID 1E8B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #77 Q4ETRON_HVBAT_CELL_V_077Confirmed
- Request
22 1E 8C - Service 22
DID 1E8C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #78 Q4ETRON_HVBAT_CELL_V_078Confirmed
- Request
22 1E 8D - Service 22
DID 1E8D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #79 Q4ETRON_HVBAT_CELL_V_079Confirmed
- Request
22 1E 8E - Service 22
DID 1E8E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #80 Q4ETRON_HVBAT_CELL_V_080Confirmed
- Request
22 1E 8F - Service 22
DID 1E8F - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #81 Q4ETRON_HVBAT_CELL_V_081Confirmed
- Request
22 1E 90 - Service 22
DID 1E90 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #82 Q4ETRON_HVBAT_CELL_V_082Confirmed
- Request
22 1E 91 - Service 22
DID 1E91 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #83 Q4ETRON_HVBAT_CELL_V_083Confirmed
- Request
22 1E 92 - Service 22
DID 1E92 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #84 Q4ETRON_HVBAT_CELL_V_084Confirmed
- Request
22 1E 93 - Service 22
DID 1E93 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #85 Q4ETRON_HVBAT_CELL_V_085Confirmed
- Request
22 1E 94 - Service 22
DID 1E94 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #86 Q4ETRON_HVBAT_CELL_V_086Confirmed
- Request
22 1E 95 - Service 22
DID 1E95 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #87 Q4ETRON_HVBAT_CELL_V_087Confirmed
- Request
22 1E 96 - Service 22
DID 1E96 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #88 Q4ETRON_HVBAT_CELL_V_088Confirmed
- Request
22 1E 97 - Service 22
DID 1E97 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #89 Q4ETRON_HVBAT_CELL_V_089Confirmed
- Request
22 1E 98 - Service 22
DID 1E98 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #90 Q4ETRON_HVBAT_CELL_V_090Confirmed
- Request
22 1E 99 - Service 22
DID 1E99 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #91 Q4ETRON_HVBAT_CELL_V_091Confirmed
- Request
22 1E 9A - Service 22
DID 1E9A - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #92 Q4ETRON_HVBAT_CELL_V_092Confirmed
- Request
22 1E 9B - Service 22
DID 1E9B - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #93 Q4ETRON_HVBAT_CELL_V_093Confirmed
- Request
22 1E 9C - Service 22
DID 1E9C - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #94 Q4ETRON_HVBAT_CELL_V_094Confirmed
- Request
22 1E 9D - Service 22
DID 1E9D - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #95 Q4ETRON_HVBAT_CELL_V_095Confirmed
- Request
22 1E 9E - Service 22
DID 1E9E - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #96 Q4ETRON_HVBAT_CELL_V_096Confirmed
- Request
22 1E 9F - Service 22
DID 1E9F - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #97 Q4ETRON_HVBAT_CELL_V_097Confirmed
- Request
22 1E A0 - Service 22
DID 1EA0 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #98 Q4ETRON_HVBAT_CELL_V_098Confirmed
- Request
22 1E A1 - Service 22
DID 1EA1 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #99 Q4ETRON_HVBAT_CELL_V_099Confirmed
- Request
22 1E A2 - Service 22
DID 1EA2 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #100 Q4ETRON_HVBAT_CELL_V_100Confirmed
- Request
22 1E A3 - Service 22
DID 1EA3 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #101 Q4ETRON_HVBAT_CELL_V_101Confirmed
- Request
22 1E A4 - Service 22
DID 1EA4 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #102 Q4ETRON_HVBAT_CELL_V_102Confirmed
- Request
22 1E A5 - Service 22
DID 1EA5 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #103 Q4ETRON_HVBAT_CELL_V_103Confirmed
- Request
22 1E A6 - Service 22
DID 1EA6 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #104 Q4ETRON_HVBAT_CELL_V_104Confirmed
- Request
22 1E A7 - Service 22
DID 1EA7 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #105 Q4ETRON_HVBAT_CELL_V_105Confirmed
- Request
22 1E A8 - Service 22
DID 1EA8 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #106 Q4ETRON_HVBAT_CELL_V_106Confirmed
- Request
22 1E A9 - Service 22
DID 1EA9 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #107 Q4ETRON_HVBAT_CELL_V_107Confirmed
- Request
22 1E AA - Service 22
DID 1EAA - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery cell voltage, #108 Q4ETRON_HVBAT_CELL_V_108Confirmed
- Request
22 1E AB - Service 22
DID 1EAB - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
Battery › Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2021.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2021.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2021.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2021.
Battery › Modules
HV battery module temperature, #5 Q4ETRON_HVBAT_MOD_T_5Confirmed
- Request
22 1E B2 - Service 22
DID 1EB2 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #6 Q4ETRON_HVBAT_MOD_T_6Confirmed
- Request
22 1E B3 - Service 22
DID 1EB3 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #7 Q4ETRON_HVBAT_MOD_T_7Confirmed
- Request
22 1E B4 - Service 22
DID 1EB4 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #8 Q4ETRON_HVBAT_MOD_T_8Confirmed
- Request
22 1E B5 - Service 22
DID 1EB5 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #9 Q4ETRON_HVBAT_MOD_T_9Confirmed
- Request
22 1E B6 - Service 22
DID 1EB6 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #10 Q4ETRON_HVBAT_MOD_T_10Confirmed
- Request
22 1E B7 - Service 22
DID 1EB7 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #11 Q4ETRON_HVBAT_MOD_T_11Confirmed
- Request
22 1E B8 - Service 22
DID 1EB8 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #12 Q4ETRON_HVBAT_MOD_T_12Confirmed
- Request
22 1E B9 - Service 22
DID 1EB9 - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #13 Q4ETRON_HVBAT_MOD_T_13Confirmed
- Request
22 1E BA - Service 22
DID 1EBA - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #14 Q4ETRON_HVBAT_MOD_T_14Confirmed
- Request
22 1E BB - Service 22
DID 1EBB - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #15 Q4ETRON_HVBAT_MOD_T_15Confirmed
- Request
22 1E BC - Service 22
DID 1EBC - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.
HV battery module temperature, #16 Q4ETRON_HVBAT_MOD_T_16Confirmed
- Request
22 1E BD - Service 22
DID 1EBD - Module
FC00 → FE007B - Every
1 s - Testing for 2022 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2021, 2024. In testing for 2022 to 2023, 2025 to 2026.