Acura ZDX

Connectable parameters

The Acura ZDX has 25 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

State of charge ACURA_SOC

Pelican can show this parameter as the state of charge.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

State of charge ACURA_SOC

Pelican can show this parameter as the state of charge.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

Fuel tank level

Fuel level ACURA_FLV

Pelican can show this parameter as the fuel tank level.

  • Request22 70 29
  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 L
Unit
L

In testing for 2010 to 2013. Not supported for 2024.

Speed

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Request01 0D
  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024.

Odometer

Odometer ACURA_ODO_PCM

Pelican can show this parameter as the odometer.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2010 to 2013, 2024.

Odometer ACURA_ODO

Pelican can show this parameter as the odometer.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2010 to 2013. Not supported for 2024.

Odometer ACURA_ODO_V2

Pelican can show this parameter as the odometer.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA1D → 1D
  • Every30 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2010 to 2013. Not supported for 2024.

Front left tire pressure

Front left tire pressure ACURA_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2010 to 2013. Not supported for 2024.

Front right tire pressure

Front right tire pressure ACURA_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2010 to 2013. Not supported for 2024.

Rear left tire pressure

Rear left tire pressure ACURA_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2010 to 2013. Not supported for 2024.

Rear right tire pressure

Rear right tire pressure ACURA_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2010 to 2013. Not supported for 2024.

Distance since trouble codes were cleared

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Request01 31
  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024.

Engine coolant temperature

Engine coolant temperature sensor 1 ACURA_ECT_1

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine coolant temperature sensor 2 ACURA_ECT_2

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine coolant temperature sensor 3 ACURA_ECT_3

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine coolant temperature sensor 4 ACURA_ECT_4

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Front left tire temperature

Front left tire temperature ACURA_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2013. Not supported for 2024.

Front right tire temperature

Front right tire temperature ACURA_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing

Bits 192 to 199 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2013. Not supported for 2024.

Rear left tire temperature

Rear left tire temperature ACURA_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2013. Not supported for 2024.

Rear right tire temperature

Rear right tire temperature ACURA_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Request22 60 01
  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2013. Not supported for 2024.

Starter battery voltage

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2024.

High voltage battery voltage, line B ACURA_HVB_V_B

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

In testing for 2010 to 2013, 2024.

Traction battery current

High voltage battery total current ACURA_HVB_C_TOTAL

Pelican can show this parameter as the traction battery current.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-100 to 200 A
Unit
A

In testing for 2010 to 2013, 2024.

Traction battery voltage

High voltage battery voltage ACURA_HVB_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

In testing for 2010 to 2013, 2024.

Transmission fluid temperature

Transmission fluid temperature ACURA_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 22 01
  • Service 22DID 2201
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013. Not supported for 2024.

Transmission fluid temperature, variant 4 ACURA_ATF_T_VAR_4

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 22 01
  • Service 22DID 2201
  • ModuleDA1E → 1E
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.