Acura ZDX

Engine parameters

The Acura ZDX has 94 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C clutch ACURA_AC_CLU_PCM

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2010 to 2013, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C clutch ACURA_AC_CLU_PCM

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2010 to 2013, 2024.

Active cylinders ACURA_ACTIVE_CYL

  • Request22 26 15
  • Service 22DID 2615
  • ModuleDA10 → 10
  • Every500 ms
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2010 to 2013. Not supported for 2024.

Active cylinders ACURA_ACTIVE_CYL_PCM

  • Request22 26 15
  • Service 22DID 2615
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2010 to 2013, 2024.

Air conditioner clutch ACURA_AC_CLU_DA11

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2010 to 2013, 2024.

Air conditioning pressure, raw count ACURA_AC_P_RAW_CNT

  • Request22 26 13
  • Service 22DID 2613
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Air/gas ratio ACURA_AIRGAS_RAT

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 2010 to 2013, 2024.

Air/gas ratio ACURA_AIRGAS_RAT_PCM

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 2010 to 2013, 2024.

Air/gas ratio ACURA_AIRGAS_RATIO

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 2010 to 2013. Not supported for 2024.

Air/gas ratio ACURA_AIRGAS_RATIO_PCM

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 2010 to 2013, 2024.

Air/gas ratio ACURA_AIRGAS_RATIO_V2

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 2010 to 2013. Not supported for 2024.

Ambient air temperature, cabin ACURA_AAT_CAB

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 832 to 839 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Ambient air temperature, outside ACURA_AAT_OUT

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 840 to 847 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Cabin air temperature ACURA_CABIN_AIR_TEMPERATURE

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 1.8 + 32)
Range
0 to 491 °F
Unit
°F

In testing for 2010 to 2013, 2024.

Catalyst temperature ACURA_CAT_T

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 1500 °C
Unit
°C

In testing for 2010 to 2013. Not supported for 2024.

DC-DC converter temperature ACURA_DC_DC_CONVERTER_TEMPERATURE

  • Request22 20 10
  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Electric load detector current ACURA_ELD_ELEC_LOAD_DUTY

  • Request22 26 61
  • Service 22DID 2661
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 A
Unit
A

In testing for 2010 to 2013, 2024.

Electric motor load ACURA_ELEC_MOTOR_LOAD

  • Request22 26 68
  • Service 22DID 2668
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
(val × 40 ÷ 51 − 100)
Range
-100 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

Electric motor load ACURA_ELEC_MOTOR_LOAD_DA10

  • Request22 26 68
  • Service 22DID 2668
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
(val × 40 ÷ 51 − 100)
Range
-100 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

Engine coolant temperature sensor 1 ACURA_ECT_1

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine coolant temperature sensor 2 ACURA_ECT_2

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine coolant temperature sensor 3 ACURA_ECT_3

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine coolant temperature sensor 4 ACURA_ECT_4

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine oil level ACURA_OIL_LEVEL

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 mm
Unit
mm

In testing for 2010 to 2013, 2024.

Engine oil temperature, variant 1 ACURA_EOT_VAR_1

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine oil temperature, variant 2 ACURA_EOT_VAR_2

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine oil temperature, variant 3 ACURA_EOT_VAR_3

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine oil temperature, variant 3 ACURA_EOT_VAR_3_PCM

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine oil temperature, variant 4 ACURA_EOT_VAR_4

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Engine oil temperature, variant 4 ACURA_EOT_VAR_4_PCM

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Evaporative purge control load ACURA_EVAP_PC_LOAD

  • Request22 26 13
  • Service 22DID 2613
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 99.61 %
Unit
%

In testing for 2010 to 2013, 2024.

Fuel/air commanded equivalence ratio ACURA_FUELAIR_CAR

  • Request22 26 61
  • Service 22DID 2661
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 2229.081633)
Range
0 to 29.4
Unit
Number

In testing for 2010 to 2013. Not supported for 2024.

Fuel/air commanded equivalence ratio ACURA_FUELAIR_CAR_PCM

  • Request22 26 61
  • Service 22DID 2661
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 2229.081633)
Range
0 to 29.4
Unit
Number

In testing for 2010 to 2013, 2024.

Generator ACURA_GEN

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

Generator ACURA_GENERATOR

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013. Not supported for 2024.

Generator ACURA_GENERATOR_DA11

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

Generator ACURA_GENERATOR_PCM

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

Knock control ACURA_KNOCK_CONTROL

ECU's determination of fuel quality.

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 2 ÷ 255)
Range
0 to 2
Unit
Raw value

In testing for 2010 to 2013. Not supported for 2024.

Knock control ACURA_KNOCK_CONTROL_V2

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 1.99 ÷ 255)
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2013. Not supported for 2024.

Maintenance, air cleaner ACURA_MAINT_AIR_CLN

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2010 to 2013, 2024.

Maintenance, brake fluid ACURA_MAINT_BRK_FLD

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2010 to 2013, 2024.

Maintenance, cabin filter ACURA_MAINT_CABIN_FLT

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2010 to 2013, 2024.

Maintenance, engine coolant ACURA_MAINT_COOL

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2010 to 2013, 2024.

Maintenance, general inspection ACURA_MAINT_INSP

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2010 to 2013, 2024.

Maintenance, oil & filter ACURA_MAINT_OIL_FLT

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2010 to 2013, 2024.

Maintenance, spark plugs & valves ACURA_MAINT_SPARK

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2010 to 2013, 2024.

Maintenance, transmission fluid ACURA_MAINT_TRANS_FLD

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2010 to 2013, 2024.

Misfire count #1, variant 1 ACURA_MIS_CNT_1_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #1, variant 1 ACURA_MISFIRE_COUNT_1_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #1, variant 2 ACURA_MISFIRE_COUNT_1_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #1, variant 3 ACURA_MIS_CNT_1_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #1, variant 3 ACURA_MISFIRE_COUNT_1_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #2, variant 1 ACURA_MIS_CNT_2_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #2, variant 1 ACURA_MISFIRE_COUNT_2_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #2, variant 2 ACURA_MISFIRE_COUNT_2_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #2, variant 3 ACURA_MIS_CNT_2_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #2, variant 3 ACURA_MISFIRE_COUNT_2_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #3, variant 1 ACURA_MIS_CNT_3_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #3, variant 1 ACURA_MISFIRE_COUNT_3_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #3, variant 2 ACURA_MISFIRE_COUNT_3_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #3, variant 3 ACURA_MIS_CNT_3_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #3, variant 3 ACURA_MISFIRE_COUNT_3_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #4, variant 1 ACURA_MIS_CNT_4_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #4, variant 1 ACURA_MISFIRE_COUNT_4_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #4, variant 2 ACURA_MISFIRE_COUNT_4_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #4, variant 3 ACURA_MIS_CNT_4_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #4, variant 3 ACURA_MISFIRE_COUNT_4_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #5, variant 1 ACURA_MIS_CNT_5_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #5, variant 1 ACURA_MISFIRE_COUNT_5_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #5, variant 2 ACURA_MISFIRE_COUNT_5_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #5, variant 3 ACURA_MIS_CNT_5_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #5, variant 3 ACURA_MISFIRE_COUNT_5_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #6, variant 1 ACURA_MIS_CNT_6_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #6, variant 1 ACURA_MISFIRE_COUNT_6_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #6, variant 2 ACURA_MISFIRE_COUNT_6_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #6, variant 3 ACURA_MIS_CNT_6_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count #6, variant 3 ACURA_MISFIRE_COUNT_6_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count 1 ACURA_MIS_CNT_1

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count 2 ACURA_MIS_CNT_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count 3 ACURA_MIS_CNT_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count 4 ACURA_MIS_CNT_4

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count, cylinder 1 ACURA_MIS_1

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count, cylinder 2 ACURA_MIS_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count, cylinder 3 ACURA_MIS_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Misfire count, cylinder 4 ACURA_MIS_4

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2013, 2024.

Motor inverter, current ACURA_MOTOR_INVERTER_CURRENT

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

In testing for 2010 to 2013, 2024.

Outside air temperature ACURA_OUTSIDE_AIR_TEMPERATURE

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val × 1.8 + 32)
Range
0 to 491 °F
Unit
°F

In testing for 2010 to 2013, 2024.

Transmission fluid temperature ACURA_ATF_T_NEW

  • Request22 22 01
  • Service 22DID 2201
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013. Not supported for 2024.

Transmission fluid temperature, variant 4 ACURA_ATF_T_VAR_4

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 22 01
  • Service 22DID 2201
  • ModuleDA1E → 1E
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2013, 2024.

Variable timing control duty ACURA_VARIABLE_TIM_CTRL

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

Variable timing control duty ACURA_VTC_DUTY_DA11

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

Variable valve timing duty ACURA_VTC_DUTY

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013. Not supported for 2024.

Variable valve timing duty ACURA_VTC_DUTY_PCM

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2013, 2024.

VTEC valve control ACURA_VTEC_VALVE_CTRL

VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2010 to 2013. Not supported for 2024.

VTEC valve control ACURA_VTEC_VALVE_CTRL_PCM

VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2010 to 2013, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.