Volvo XC40

Transmission parameters

The Volvo XC40 has 12 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Clutch 1 temperature XC40_CLU_1_T

  • Request22 D9 26
  • Service 22DID D926
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2017 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Clutch 1 temperature XC40_CLU_1_T

  • Request22 D9 26
  • Service 22DID D926
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2017 to 2026.

Clutch 2 temperature XC40_CLU_2_T

  • Request22 D9 40
  • Service 22DID D940
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2017 to 2026.

Clutch actuator 1 temperature XC40_CLU_ACTUATOR_1_T

  • Request22 D9 6B
  • Service 22DID D96B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2017 to 2026.

Clutch actuator 2 temperature XC40_CLU_ACTUATOR_2_T

  • Request22 D9 74
  • Service 22DID D974
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2017 to 2026.

Clutch pump duty XC40_CLU_PMP_DUTY

  • Request22 D9 20
  • Service 22DID D920
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2022. Not supported for 2023.

Gear XC40_GEAR

  • Request22 DA 85
  • Service 22DID DA85
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing for 2017 to 2022, 2024 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Gear ratio, actual XC40_GEAR_RAT_ACT

  • Request22 DA 34
  • Service 22DID DA34
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 61 ÷ 250000)
Range
0 to 15.99
Unit
Number

In testing for 2017 to 2022. Not supported for 2023.

Gear ratio, requested XC40_GEAR_RAT_REQ

  • Request22 DA 47
  • Service 22DID DA47
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2017 to 2022. Not supported for 2023.

Torque converter lock XC40_TQ_CONV_LOCK

  • Request22 DA 3C
  • Service 22DID DA3C
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022. Not supported for 2023.

Transmission fluid temperature XC40_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 DA 3B
  • Service 22DID DA3B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2017 to 2022. Not supported for 2023.

Transmission fluid temperature XC40_ATF_T_D016

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D9 0D
  • Service 22DID D90D
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 °C
Unit
°C

In testing for 2017 to 2026.

Transmission fluid temperature XC40_ATF_T_D016_2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D9 00
  • Service 22DID D900
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1000)
Range
-32768000 to 32767000 °C
Unit
°C

In testing for 2017 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.