Battery parameters
The Volvo XC40 has 30 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery state of charge XC40_12V_BAT_ST_CHG
- Request
22 49 46 - Service 22
DID 4946 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1024 ÷ 15625)- Range
- 0 to 4294 %
- Unit
- %
In testing for 2017 to 2026.
Auxiliary battery current XC40_AUXILIARY_BAT
- Request
22 41 12 - Service 22
DID 4112 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Auxiliary battery temperature XC40_AUXILIARY_BAT_T
- Request
22 40 D3 - Service 22
DID 40D3 - Module
D01A → 1F402E80 - Every
5 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Auxiliary battery voltage XC40_AUXILIARY_BAT_V
- Request
22 41 7E - Service 22
DID 417E - Module
D01A → 1F402E80 - Every
5 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Average static low range battery current XC40_AVG_STATIC_LOW_RANGE
- Request
22 40 25 - Service 22
DID 4025 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 mA
- Unit
- mA
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Battery current XC40_BAT_CURRENT
- Request
22 40 90 - Service 22
DID 4090 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 512)- Range
- -512 to 3583 A
- Unit
- A
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Battery state of charge XC40_BAT_ST_CHG
- Request
22 40 28 - Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Battery voltage XC40_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 CD - Service 22
DID 40CD - Module
D01A → 1F402E80 - Every
5 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 + 5)- Range
- 0 to 1643 V
- Unit
- V
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Charge air pressure XC40_CHG_AIR_P
- Request
22 EE 3E - Service 22
DID EE3E - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.007812)- Range
- 0 to 511 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Charger cable current XC40_CHARGER_CABLE
- Request
22 EE 8D - Service 22
DID EE8D - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 410)- Range
- -410 to 6143 A
- Unit
- A
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Charging socket lock XC40_CHG_SOCKET_LOCKED
- Request
22 EE 8C - Service 22
DID EE8C - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | UNLOCKED | Unlocked |
2 | LOCKED | Locked |
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2022. Supported for 2019 to 2021, 2023.
DC charger current XC40_DC_CHARGER_CURRENT
- Request
22 EE 16 - Service 22
DID EE16 - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
DC charger voltage XC40_DC_CHARGER_V
- Request
22 EE 17 - Service 22
DID EE17 - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery current XC40_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 48 02 - Service 22
DID 4802 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 A
- Unit
- A
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery state of charge XC40_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 %
- Unit
- %
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery voltage XC40_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 48 03 - Service 22
DID 4803 - Module
D016 → 1EC6AE80 - Every
5 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery, average temperature XC40_HVBAT_AVG_T
- Request
22 49 1B - Service 22
DID 491B - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery, coolant pump speed, actual XC40_HVBAT_CLT_PMP_SPD_ACT
- Request
22 48 67 - Service 22
DID 4867 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery, coolant pump speed, requested XC40_HVBAT_CLT_PMP_SPD
- Request
22 48 66 - Service 22
DID 4866 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery, high-voltage coolant heater fuse voltage XC40_HVBAT_HVCH_FUSE_V
- Request
22 48 0A - Service 22
DID 480A - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2022. Not supported for 2023.
High voltage battery, IEM fuse voltage XC40_HVBAT_IEM_FUSE_V
- Request
22 48 08 - Service 22
DID 4808 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2022. Not supported for 2023.
High voltage battery, IGM fuse voltage XC40_HVBAT_IGM_FUSE_V
- Request
22 48 09 - Service 22
DID 4809 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery, inlet coolant temperature XC40_HVBAT_INLET_ECT
- Request
22 48 04 - Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery, max temperature XC40_HVBAT_MAX_T
- Request
22 49 45 - Service 22
DID 4945 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
High voltage battery, OBC fuse voltage XC40_HVBAT_OBC_FUSE_V
- Request
22 48 0B - Service 22
DID 480B - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Request
01 5B - Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2023.
Main charger current XC40_MAIN_CHARGER_CURRENT
- Request
22 EE 15 - Service 22
DID EE15 - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Main charger voltage XC40_MAIN_CHARGER_V
- Request
22 EE 1C - Service 22
DID EE1C - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.
Module voltage XC40_MODULE_V
- Request
22 D1 11 - Service 22
DID D111 - Module
D016 → 1EC70E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2022. Not supported for 2023.