Volvo XC40

Battery parameters

The Volvo XC40 has 30 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery state of charge XC40_12V_BAT_ST_CHG

  • Request22 49 46
  • Service 22DID 4946
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1024 ÷ 15625)
Range
0 to 4294 %
Unit
%

In testing for 2017 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery state of charge XC40_12V_BAT_ST_CHG

  • Request22 49 46
  • Service 22DID 4946
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1024 ÷ 15625)
Range
0 to 4294 %
Unit
%

In testing for 2017 to 2026.

Auxiliary battery current XC40_AUXILIARY_BAT

  • Request22 41 12
  • Service 22DID 4112
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 127)
Range
-127 to 128 A
Unit
A

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Auxiliary battery temperature XC40_AUXILIARY_BAT_T

  • Request22 40 D3
  • Service 22DID 40D3
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Auxiliary battery voltage XC40_AUXILIARY_BAT_V

  • Request22 41 7E
  • Service 22DID 417E
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Average static low range battery current XC40_AVG_STATIC_LOW_RANGE

  • Request22 40 25
  • Service 22DID 4025
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 511)
Range
-511 to 65024 mA
Unit
mA

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Battery current XC40_BAT_CURRENT

  • Request22 40 90
  • Service 22DID 4090
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 512)
Range
-512 to 3583 A
Unit
A

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Battery state of charge XC40_BAT_ST_CHG

  • Request22 40 28
  • Service 22DID 4028
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Battery voltage XC40_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 40 CD
  • Service 22DID 40CD
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40 + 5)
Range
0 to 1643 V
Unit
V

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Charge air pressure XC40_CHG_AIR_P

  • Request22 EE 3E
  • Service 22DID EE3E
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.007812)
Range
0 to 511 kPa
Unit
kPa

In testing for 2017 to 2026.

Charger cable current XC40_CHARGER_CABLE

  • Request22 EE 8D
  • Service 22DID EE8D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 410)
Range
-410 to 6143 A
Unit
A

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Charging socket lock XC40_CHG_SOCKET_LOCKED

  • Request22 EE 8C
  • Service 22DID EE8C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2022. Supported for 2019 to 2021, 2023.

DC charger current XC40_DC_CHARGER_CURRENT

  • Request22 EE 16
  • Service 22DID EE16
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 A
Unit
A

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

DC charger voltage XC40_DC_CHARGER_V

  • Request22 EE 17
  • Service 22DID EE17
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery current XC40_HVBAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Request22 48 02
  • Service 22DID 4802
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 A
Unit
A

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery state of charge XC40_HVBAT_ST_CHG

Pelican can show this parameter as the state of charge.

  • Request22 48 01
  • Service 22DID 4801
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 131 %
Unit
%

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery voltage XC40_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 48 03
  • Service 22DID 4803
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery, average temperature XC40_HVBAT_AVG_T

  • Request22 49 1B
  • Service 22DID 491B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 50)
Range
-50 to 605 °C
Unit
°C

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery, coolant pump speed, actual XC40_HVBAT_CLT_PMP_SPD_ACT

  • Request22 48 67
  • Service 22DID 4867
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 24)
Range
0 to 6120 rpm
Unit
rpm

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery, coolant pump speed, requested XC40_HVBAT_CLT_PMP_SPD

  • Request22 48 66
  • Service 22DID 4866
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 24)
Range
0 to 6120 rpm
Unit
rpm

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery, high-voltage coolant heater fuse voltage XC40_HVBAT_HVCH_FUSE_V

  • Request22 48 0A
  • Service 22DID 480A
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2017 to 2022. Not supported for 2023.

High voltage battery, IEM fuse voltage XC40_HVBAT_IEM_FUSE_V

  • Request22 48 08
  • Service 22DID 4808
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2017 to 2022. Not supported for 2023.

High voltage battery, IGM fuse voltage XC40_HVBAT_IGM_FUSE_V

  • Request22 48 09
  • Service 22DID 4809
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery, inlet coolant temperature XC40_HVBAT_INLET_ECT

  • Request22 48 04
  • Service 22DID 4804
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery, max temperature XC40_HVBAT_MAX_T

  • Request22 49 45
  • Service 22DID 4945
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 100 − 50)
Range
-50 to 605 °C
Unit
°C

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

High voltage battery, OBC fuse voltage XC40_HVBAT_OBC_FUSE_V

  • Request22 48 0B
  • Service 22DID 480B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Request01 5B
  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020 to 2023.

Main charger current XC40_MAIN_CHARGER_CURRENT

  • Request22 EE 15
  • Service 22DID EE15
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 A
Unit
A

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Main charger voltage XC40_MAIN_CHARGER_V

  • Request22 EE 1C
  • Service 22DID EE1C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023.

Module voltage XC40_MODULE_V

  • Request22 D1 11
  • Service 22DID D111
  • ModuleD016 → 1EC70E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2017 to 2022. Not supported for 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.