Volvo V50

Fuel parameters

The Volvo V50 has 20 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel filter heater VOLVO_FUEL_FLT_HEATER

  • Request22 DC 14
  • Service 22DID DC14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2012.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Fuel filter heater VOLVO_FUEL_FLT_HEATER

  • Request22 DC 14
  • Service 22DID DC14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2012.

Fuel filter heater VOLVO_FUEL_FLT_HEATER_7E0

  • Request22 DB 35
  • Service 22DID DB35
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2012.

Fuel heater fan adjustment VOLVO_FUEL_HEATER_FAN_ADJ

  • Request22 9A 03
  • Service 22DID 9A03
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2004 to 2012.

Fuel high pressure VOLVO_FUEL_HIGH_P

  • Request22 EE 4F
  • Service 22DID EE4F
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000)
Range
0 to 32.76
Unit
Raw value

In testing for 2004 to 2012.

Fuel level 1 of 2 VOLVO_DIM_FLI_1_2

  • Request22 61 D1
  • Service 22DID 61D1
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 L
Unit
L

In testing for 2004 to 2012.

Fuel level 2 of 2 ejector side saddle tank VOLVO_DIM_FLI_2_2_EJECTOR

  • Request22 61 D0
  • Service 22DID 61D0
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 L
Unit
L

In testing for 2004 to 2012.

Fuel level damped VOLVO_DIM_FLI_DAMPED

  • Request22 EE 11
  • Service 22DID EE11
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 L
Unit
L

In testing for 2004 to 2012.

Fuel level damped VOLVO_FLI_DAMPED

  • Request22 EE 12
  • Service 22DID EE12
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 L
Unit
L

In testing for 2004 to 2012.

Fuel level input VOLVO_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Request22 F4 2F
  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2004 to 2012.

Fuel level sensor VOLVO_FLI_SENS

  • Request22 41 17
  • Service 22DID 4117
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 20459)
Range
0 to 320 V
Unit
V

In testing for 2004 to 2012.

Fuel level sensor ejector side saddle tank VOLVO_FLI_SENS_EJECTOR

  • Request22 41 18
  • Service 22DID 4118
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 20459)
Range
0 to 320 V
Unit
V

In testing for 2004 to 2012.

Fuel low pressure VOLVO_FUEL_LOW_P

  • Request22 EE 57
  • Service 22DID EE57
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2004 to 2012.

Fuel pressure VOLVO_FUEL_P

  • Request22 F4 23
  • Service 22DID F423
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100)
Range
0 to 6553500
Unit
Raw value

In testing for 2004 to 2012.

Fuel pressure VOLVO_FUEL_P_DA10

  • Request22 F4 0A
  • Service 22DID F40A
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2004 to 2012.

Fuel pressure nominal value VOLVO_FUEL_P_NOMINAL

  • Request22 D9 FF
  • Service 22DID D9FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100)
Range
0 to 6553500
Unit
Raw value

In testing for 2004 to 2012.

Fuel pressure regulator valve current VOLVO_FUEL_P_REGULATOR_VLV

  • Request22 D9 EE
  • Service 22DID D9EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2004 to 2012.

Fuel pump low pressure side duty cycle VOLVO_FUEL_PMP_LOW_P_SIDE

  • Request22 EF 59
  • Service 22DID EF59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2004 to 2012.

Fuel temperature VOLVO_FUEL_T

  • Request22 D9 9C
  • Service 22DID D99C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2004 to 2012.

Fuel volume control valve VOLVO_FUEL_VOLUME_CTRL_VLV

  • Request22 DA D5
  • Service 22DID DAD5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2004 to 2012.

Fuel volume control valve VOLVO_FUEL_VOLUME_CTRL_VLV_7E0

  • Request22 DC 13
  • Service 22DID DC13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2004 to 2012.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.