Climate parameters
The Volvo V50 has 15 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
Auxiliary water pump duty cycle VOLVO_AUXILIARY_WATER_PMP
- Request
22 43 36 - Service 22
DID 4336 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2004 to 2012.
Cabin blower command VOLVO_BLOWER
- Request
22 34 CB - Service 22
DID 34CB - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2012.
Evaporator temperature VOLVO_EVAPORATOR_T
- Request
22 98 4F - Service 22
DID 984F - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2004 to 2012.
Evaporator temperature v.2 VOLVO_EVAPORATOR_T_V_2
- Request
22 98 20 - Service 22
DID 9820 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 16 ÷ 5)- Range
- -409 to 406 °C
- Unit
- °C
In testing for 2004 to 2012.
Fuel-operated heater, inlet water temperature VOLVO_FOH_INLET_WATER_T
- Request
22 43 BE - Service 22
DID 43BE - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2012.
Fuel-operated heater, outlet water temperature VOLVO_FOH_OUTLET_WATER_T
- Request
22 43 BE - Service 22
DID 43BE - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2012.
Heat exchanger temperature VOLVO_HEAT_EXCHANGER_T
- Request
22 98 50 - Service 22
DID 9850 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2004 to 2012.
Heat exchanger temperature v.2 VOLVO_HEAT_EXCHANGER_T_V_2
- Request
22 43 37 - Service 22
DID 4337 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 16 ÷ 5)- Range
- -409 to 406 °C
- Unit
- °C
In testing for 2004 to 2012.
High-voltage coolant heater coolant inlet temperature VOLVO_HVCH_CLT_INLET_T
- Request
22 43 44 - Service 22
DID 4344 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2012.
High-voltage coolant heater coolant outlet temperature VOLVO_HVCH_CLT_OUTLET_T
- Request
22 43 44 - Service 22
DID 4344 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2012.
High-voltage coolant heater current consumption VOLVO_HVCH_CURRENT_CONS
- Request
22 43 45 - Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 A
- Unit
- A
In testing for 2004 to 2012.
High-voltage coolant heater power consumption VOLVO_HVCH_POWER_CONS
- Request
22 43 45 - Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700 W
- Unit
- W
In testing for 2004 to 2012.
High-voltage coolant heater required power consumption VOLVO_HVCH_REQUIRED_POWER
- Request
22 43 45 - Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700 W
- Unit
- W
In testing for 2004 to 2012.
Interior temperature VOLVO_INTERIOR_T
- Request
22 98 43 - Service 22
DID 9843 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4 ÷ 5 − 60)- Range
- -60 to 144 °C
- Unit
- °C
In testing for 2004 to 2012.
Outside temperature VOLVO_AAT
- Request
22 20 0C - Service 22
DID 200C - Module
743 → 763 - Every
20 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2004 to 2012.