Volkswagen e-Up

Control parameters

The Volkswagen e-Up has 7 control parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Accelerator pedal position EUP_APP_PE

  • Request22 F4 49
  • Service 22DID F449
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Accelerator pedal position EUP_APP_PE

  • Request22 F4 49
  • Service 22DID F449
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

Accelerator pedal position 1 EUP_APP1

  • Request22 F4 49
  • Service 22DID F449
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

Accelerator pedal position 2 EUP_APP2

  • Request22 F4 4A
  • Service 22DID F44A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

Accelerator pedal release detection threshold voltage EUP_APP_REDUCE_V

  • Request22 10 29
  • Service 22DID 1029
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2023.

Accelerator pedal sensor 1 voltage EUP_APP_V1

  • Request22 10 2A
  • Service 22DID 102A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2023.

Accelerator pedal sensor 2 voltage EUP_APP_V2

  • Request22 10 2B
  • Service 22DID 102B
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2023.

Downshift point adaptation voltage EUP_DOWNSHIFT_ADAPT_V

  • Request22 10 28
  • Service 22DID 1028
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.