Volkswagen e-Up

Connectable parameters

The Volkswagen e-Up has 12 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery charge EUP_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Request22 02 8C
  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

HV battery charge EUP_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Request22 02 8C
  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

HV battery charge, displayed EUP_HVBAT_SOC_DISP

Pelican can show this parameter as the state of charge.

  • Request22 11 64
  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

State of health

HV battery health EUP_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Request22 51 E0
  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.127 − 1798.574)
Range
-1798.574 to 100 %
Unit
%

In testing for 2013 to 2023.

Speed

Vehicle speed EUP_VSS

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Request22 F4 0D
  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2013 to 2023.

Electric range

Range remaining, displayed EUP_RANGE_DSP

Pelican can show this parameter as the electric range.

  • Request22 22 E0
  • Service 22DID 22E0
  • Module714 → 77E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2013 to 2023.

Odometer

Odometer EUP_ODO

Pelican can show this parameter as the odometer.

  • Request22 22 03
  • Service 22DID 2203
  • Module714 → 77E
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2013 to 2023.

Distance since trouble codes were cleared

Distance traveled since diagnostic trouble codes cleared EUP_CLR_DIST

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Request22 F4 31
  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2013 to 2023.

Engine speed

Drive motor speed, actual EUP_MOTOR_RPM

Pelican can show this parameter as the engine speed.

  • Request22 3E 97
  • Service 22DID 3E97
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2013 to 2023.

Starter battery voltage

Battery voltage EUP_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 5A
  • Service 22DID 105A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20)
Range
0 to 1310700 mV
Unit
mV

In testing for 2013 to 2023.

Terminal 30 voltage EUP_KL30_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 F4 42
  • Service 22DID F442
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65 V
Unit
V

In testing for 2013 to 2023.

Traction battery current

HV battery current EUP_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Request22 1E 3D
  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4 − 511)
Range
-200 to 200 A
Unit
A

In testing for 2013 to 2023.

Traction battery voltage

HV battery voltage EUP_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 1E 3B
  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 1000 V
Unit
V

In testing for 2013 to 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.