Volkswagen Atlas

Fuel parameters

The Volkswagen Atlas has 24 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level ATLAS_PQ35_FUEL_LEVEL_7E0_2206Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 22 06
  • Service 22DID 2206
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2017 to 2020, 2022 to 2026

Example reply from a 2021 Volkswagen Atlas.

Bits 0 to 7 of the reply, 8 bits.

0x07 = 7 → 7 L

Formula
val
Range
0 to 255 L
Unit
L

Confirmed for 2021. In testing for 2017, 2020, 2022, 2025. Not supported for 2018 to 2019, 2023 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Counter of fuel entry in oil ATLAS_CNT_FUEL_ENTRY_OIL

  • Request22 39 9F
  • Service 22DID 399F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2024 to 2025. Supported for 2021.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024 to 2025. Supported for 2021.

Error counter bad fuel ATLAS_ERROR_CNT_BAD_FUEL

  • Request22 44 BB
  • Service 22DID 44BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Fuel consumption ATLAS_FUEL_CONSConfirmed

  • Request22 11 3F
  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2017, 2020, 2022, 2024 to 2026

Example reply from a 2023 Volkswagen Atlas.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0 L

Formula
(val ÷ 100)
Range
0 to 655.35 L
Unit
L

Confirmed for 2018 to 2019, 2021, 2023. In testing for 2017, 2020, 2022. Not supported for 2024 to 2026.

Fuel flow ATLAS_FUEL_FLOW

  • Request22 10 A0
  • Service 22DID 10A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 L
Unit
L

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Fuel level ATLAS_FLI

  • Request22 10 08
  • Service 22DID 1008
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Fuel level ATLAS_PQ35_FUEL_LEVEL_7E0_2206Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 22 06
  • Service 22DID 2206
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2017 to 2020, 2022 to 2026

Example reply from a 2021 Volkswagen Atlas.

Bits 0 to 7 of the reply, 8 bits.

0x07 = 7 → 7 L

Formula
val
Range
0 to 255 L
Unit
L

Confirmed for 2021. In testing for 2017, 2020, 2022, 2025. Not supported for 2018 to 2019, 2023 to 2024, 2026.

Fuel level input, v1 ATLAS_FUEL_LEVEL_INPUT_V1Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 14 B4
  • Service 22DID 14B4
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2017, 2020, 2022, 2024 to 2026

Example reply from a 2023 Volkswagen Atlas.

Bits 0 to 15 of the reply, 16 bits.

0x0708 = 1800 → (1800 ÷ 100) = 18 L

Formula
(val ÷ 100)
Range
0 to 655.35 L
Unit
L

Confirmed for 2018 to 2019, 2021, 2023. In testing for 2017, 2020, 2022, 2025. Not supported for 2024, 2026.

Fuel mass request, integral controller ATLAS_FUEL_MASS_REQ_I_CTL

  • Request22 13 0D
  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 10597 ÷ 500000)
Range
-694 to 694
Unit
Raw value

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Fuel mass request, proportional controller ATLAS_FUEL_MASS_REQ_P_CTL

  • Request22 13 12
  • Service 22DID 1312
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 10597 ÷ 500000)
Range
-694 to 694
Unit
Raw value

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pressure regulator position ATLAS_PQ35_FUEL_P_REGConfirmed

  • Request22 11 BF
  • Service 22DID 11BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2020, 2022, 2024 to 2026

Example reply from a 2023 Volkswagen Atlas.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0003 = 3 → (3 ÷ 100) = 0.03 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2018 to 2019, 2021, 2023. In testing for 2017, 2020, 2022, 2025. Not supported for 2024, 2026.

Fuel pressure regulator valve: specified value rail pressure ATLAS_SPEC_VALUE_RAIL_PConfirmed

  • Request22 12 1E
  • Service 22DID 121E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017 to 2020, 2022 to 2026

Example reply from a 2021 Volkswagen Atlas.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x16A3 = 5795 → (5795 × 100) = 579,500

Formula
(val × 100)
Range
-3276800 to 3276700
Unit
Raw value

Confirmed for 2021. In testing for 2017, 2020, 2022. Not supported for 2018 to 2019, 2023 to 2026.

Fuel pressure, low actual ATLAS_FUEL_P_LOW_ACT

  • Request22 1A B8
  • Service 22DID 1AB8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Fuel pump specified value ATLAS_FUEL_PMP_SPEC

  • Request22 11 09
  • Service 22DID 1109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2018, 2024 to 2025. Supported for 2019 to 2021, 2023, 2026.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2018, 2024 to 2025. Supported for 2019 to 2021, 2023, 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2021, 2024 to 2025. Supported for 2019 to 2020, 2023, 2026.

Fuel temperature ATLAS_FUEL_T_7E0_2

  • Request22 11 1C
  • Service 22DID 111C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

High fuel pressure control deviation ATLAS_HIGH_FUEL_P_CONTROL_DEVIATIONConfirmed

  • Request22 12 1F
  • Service 22DID 121F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017 to 2020, 2022 to 2026

Example reply from a 2021 Volkswagen Atlas.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x2B0B = 11019 → (11019 × 100) = 1,101,900

Formula
(val × 100)
Range
-3276800 to 3276700
Unit
Raw value

Confirmed for 2021. In testing for 2017, 2020, 2022. Not supported for 2018 to 2019, 2023 to 2026.

High fuel pressure, target ATLAS_HIGH_FUEL_P_TGT

  • Request22 11 1B
  • Service 22DID 111B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000)
Range
0 to 32.76
Unit
Raw value

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Long term fuel trim at idle ATLAS_LONG_TERM_FUEL_TRIM_7E0

  • Request22 11 0E
  • Service 22DID 110E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638 to 1638 %
Unit
%

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Long term fuel trim at idle ATLAS_LONG_TERM_FUEL_TRIM_IDLE_7E0

  • Request22 43 81
  • Service 22DID 4381
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024 to 2025. Supported for 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.