Fuel parameters
The Volkswagen Atlas has 24 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Counter of fuel entry in oil ATLAS_CNT_FUEL_ENTRY_OIL
- Request
22 39 9F - Service 22
DID 399F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Request
01 9E - Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2024 to 2025. Supported for 2021.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024 to 2025. Supported for 2021.
Error counter bad fuel ATLAS_ERROR_CNT_BAD_FUEL
- Request
22 44 BB - Service 22
DID 44BB - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Fuel consumption ATLAS_FUEL_CONSConfirmed
- Request
22 11 3F - Service 22
DID 113F - Module
7E0 → 7E8 - Every
30 s - Testing for 2017, 2020, 2022, 2024 to 2026
Example reply from a 2023 Volkswagen Atlas.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0 L
- Formula
(val ÷ 100)- Range
- 0 to 655.35 L
- Unit
- L
Confirmed for 2018 to 2019, 2021, 2023. In testing for 2017, 2020, 2022. Not supported for 2024 to 2026.
Fuel flow ATLAS_FUEL_FLOW
- Request
22 10 A0 - Service 22
DID 10A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 L
- Unit
- L
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Fuel level ATLAS_FLI
- Request
22 10 08 - Service 22
DID 1008 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Fuel level ATLAS_PQ35_FUEL_LEVEL_7E0_2206Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 22 06 - Service 22
DID 2206 - Module
7E0 → 7E8 - Every
30 s - Testing for 2017 to 2020, 2022 to 2026
Example reply from a 2021 Volkswagen Atlas.
Bits 0 to 7 of the reply, 8 bits.
0x07 = 7 → 7 L
- Formula
val- Range
- 0 to 255 L
- Unit
- L
Confirmed for 2021. In testing for 2017, 2020, 2022, 2025. Not supported for 2018 to 2019, 2023 to 2024, 2026.
Fuel level input, v1 ATLAS_FUEL_LEVEL_INPUT_V1Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 14 B4 - Service 22
DID 14B4 - Module
7E0 → 7E8 - Every
30 s - Testing for 2017, 2020, 2022, 2024 to 2026
Example reply from a 2023 Volkswagen Atlas.
Bits 0 to 15 of the reply, 16 bits.
0x0708 = 1800 → (1800 ÷ 100) = 18 L
- Formula
(val ÷ 100)- Range
- 0 to 655.35 L
- Unit
- L
Confirmed for 2018 to 2019, 2021, 2023. In testing for 2017, 2020, 2022, 2025. Not supported for 2024, 2026.
Fuel mass request, integral controller ATLAS_FUEL_MASS_REQ_I_CTL
- Request
22 13 0D - Service 22
DID 130D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 10597 ÷ 500000)- Range
- -694 to 694
- Unit
- Raw value
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Fuel mass request, proportional controller ATLAS_FUEL_MASS_REQ_P_CTL
- Request
22 13 12 - Service 22
DID 1312 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 10597 ÷ 500000)- Range
- -694 to 694
- Unit
- Raw value
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Fuel pressure regulator position ATLAS_PQ35_FUEL_P_REGConfirmed
- Request
22 11 BF - Service 22
DID 11BF - Module
7E0 → 7E8 - Every
1 s - Testing for 2017, 2020, 2022, 2024 to 2026
Example reply from a 2023 Volkswagen Atlas.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0003 = 3 → (3 ÷ 100) = 0.03 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018 to 2019, 2021, 2023. In testing for 2017, 2020, 2022, 2025. Not supported for 2024, 2026.
Fuel pressure regulator valve: specified value rail pressure ATLAS_SPEC_VALUE_RAIL_PConfirmed
- Request
22 12 1E - Service 22
DID 121E - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2020, 2022 to 2026
Example reply from a 2021 Volkswagen Atlas.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x16A3 = 5795 → (5795 × 100) = 579,500
- Formula
(val × 100)- Range
- -3276800 to 3276700
- Unit
- Raw value
Confirmed for 2021. In testing for 2017, 2020, 2022. Not supported for 2018 to 2019, 2023 to 2026.
Fuel pressure, low actual ATLAS_FUEL_P_LOW_ACT
- Request
22 1A B8 - Service 22
DID 1AB8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Fuel pump specified value ATLAS_FUEL_PMP_SPEC
- Request
22 11 09 - Service 22
DID 1109 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2018, 2024 to 2025. Supported for 2019 to 2021, 2023, 2026.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2018, 2024 to 2025. Supported for 2019 to 2021, 2023, 2026.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2021, 2024 to 2025. Supported for 2019 to 2020, 2023, 2026.
Fuel temperature ATLAS_FUEL_T_7E0_2
- Request
22 11 1C - Service 22
DID 111C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
High fuel pressure control deviation ATLAS_HIGH_FUEL_P_CONTROL_DEVIATIONConfirmed
- Request
22 12 1F - Service 22
DID 121F - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2020, 2022 to 2026
Example reply from a 2021 Volkswagen Atlas.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x2B0B = 11019 → (11019 × 100) = 1,101,900
- Formula
(val × 100)- Range
- -3276800 to 3276700
- Unit
- Raw value
Confirmed for 2021. In testing for 2017, 2020, 2022. Not supported for 2018 to 2019, 2023 to 2026.
High fuel pressure, target ATLAS_HIGH_FUEL_P_TGT
- Request
22 11 1B - Service 22
DID 111B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000)- Range
- 0 to 32.76
- Unit
- Raw value
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Long term fuel trim at idle ATLAS_LONG_TERM_FUEL_TRIM_7E0
- Request
22 11 0E - Service 22
DID 110E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638 to 1638 %
- Unit
- %
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Long term fuel trim at idle ATLAS_LONG_TERM_FUEL_TRIM_IDLE_7E0
- Request
22 43 81 - Service 22
DID 4381 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2017 to 2023, 2025 to 2026. Not supported for 2024.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024 to 2025. Supported for 2021.