Vauxhall/Opel Ampera

Engine parameters

The Vauxhall/Opel Ampera has 355 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

5V power supply state number 1 VAUXHALLOPEL_5V_POWER_SUP_ST_1

  • Request22 D4 23
  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

5V power supply state number 1 VAUXHALLOPEL_5V_POWER_SUP_ST_1

  • Request22 D4 23
  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

5V power supply state number 2 VAUXHALLOPEL_5V_POWER_SUP_ST_2

  • Request22 D4 24
  • Service 22DID D424
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

5V power supply state number 3 VAUXHALLOPEL_5V_POWER_SUP_ST_3

  • Request22 D4 25
  • Service 22DID D425
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

5V power supply state number 4 VAUXHALLOPEL_5V_POWER_SUP_ST_4

  • Request22 D4 26
  • Service 22DID D426
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

12V network allowed stop VAUXHALLOPEL_12V_NETWORK_ALLOWED

  • Request22 D7 4C
  • Service 22DID D74C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Activation count, brake electromagnetic valve B1 VAUXHALLOPEL_NUM_ACTIVATIONS_B1

  • Request22 D7 45
  • Service 22DID D745
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Activation count, line pressure control solenoid VAUXHALLOPEL_NUM_LINE_P_CTRL

  • Request22 D7 51
  • Service 22DID D751
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Activation count, the electromagnetic valve of brake B2 VAUXHALLOPEL_NUM_ACTIVATIONS_B2

  • Request22 D7 5A
  • Service 22DID D75A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Actual oil pressure VAUXHALLOPEL_ACT_OIL_P

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Additional heater control 1 VAUXHALLOPEL_ADDITIONAL_HEATER_1

  • Request22 D4 16
  • Service 22DID D416
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

AFT DPF oulet pressure sensor VAUXHALLOPEL_AFT_DPF_OULET_P_SENS

  • Request22 A0 0A
  • Service 22DID A00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 2000)
Range
0 to 294 psi
Unit
psi

In testing for 2011 to 2015, 2017 to 2019.

Air conditioning VAUXHALLOPEL_AC

  • Request22 D4 AF
  • Service 22DID D4AF
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Air conditioning compressor current VAUXHALLOPEL_AC_COMP_CURRENT

  • Request22 D4 1C
  • Service 22DID D41C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Air conditioning high side pressure VAUXHALLOPEL_AC_HIGH_SIDE_P

  • Request22 03 29
  • Service 22DID 0329
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 14)
Range
0 to 3570 kPa
Unit
kPa

In testing for 2011 to 2015, 2017 to 2019.

Air conditioning high side pressure VAUXHALLOPEL_AC_HIGH_SIDE_P_7E0

  • Request21 A7
  • Service 21PID A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 55)
Range
0 to 1191 psi
Unit
psi

In testing for 2011 to 2015, 2017 to 2019.

Air conditioning high side pressure VAUXHALLOPEL_AC_HIGH_SIDE_P_V2

  • Request22 D8 FF
  • Service 22DID D8FF
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Air conditioning pressure VAUXHALLOPEL_AC_P

  • Request22 D4 21
  • Service 22DID D421
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Air conditioning refrigerant pressure VAUXHALLOPEL_AC_REFRIGERANT_P

  • Request22 40 01
  • Service 22DID 4001
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Air doser first electronic loading VAUXHALLOPEL_AIR_DOSER_FIRST

  • Request22 D5 3B
  • Service 22DID D53B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Air flow VAUXHALLOPEL_AIR_FLOW

  • Request22 D4 89
  • Service 22DID D489
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Air flow target VAUXHALLOPEL_AIR_FLOW_TGT

  • Request22 D4 8E
  • Service 22DID D48E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Air heater core temperature VAUXHALLOPEL_AIRHEATER_CORE_T

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Air heater current VAUXHALLOPEL_AIRHEATER_CURRENT

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 A
Unit
A

In testing for 2011 to 2015, 2017 to 2019.

Air heater power consumption VAUXHALLOPEL_AIRHEATER_POWER_CONS

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Air metering valve duty cycle VAUXHALLOPEL_AIR_METERING_VLV

  • Request22 D4 61
  • Service 22DID D461
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Air metering valve position VAUXHALLOPEL_AIR_METERING_VLV_POS

  • Request22 D5 4F
  • Service 22DID D54F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Air metering valve, target position VAUXHALLOPEL_AIR_METERING_VLV_TGT

  • Request22 D4 60
  • Service 22DID D460
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Air temperature by air flow meter VAUXHALLOPEL_AIR_T_AIR_FLOW_METER

  • Request22 D5 4E
  • Service 22DID D54E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Alternator load value VAUXHALLOPEL_ALTERNATOR_LOAD

  • Request22 D4 A5
  • Service 22DID D4A5
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Ambient air temperature VAUXHALLOPEL_AAT_6A9

  • Request22 D5 52
  • Service 22DID D552
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Ambient air temperature VAUXHALLOPEL_AAT_7E0

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Ambient temperature VAUXHALLOPEL_AAT

  • Request22 01 27
  • Service 22DID 0127
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 83)
Range
-83 to 376 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Ambient temperature VAUXHALLOPEL_AAT_V2

  • Request22 D4 34
  • Service 22DID D434
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

ANTI START PROGRAMMING STATUS VAUXHALLOPEL_ANTI_START

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Assessment of thermal aging of the particulate filter VAUXHALLOPEL_ASSESSMENT_THERMAL

  • Request22 D5 32
  • Service 22DID D532
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 128)
Range
0 to 12799 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

AT main cylinder pressure VAUXHALLOPEL_MAIN_CYL_P

  • Request22 50 34
  • Service 22DID 5034
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Atmospheric pressure VAUXHALLOPEL_ATMOSPHERIC_P

  • Request22 D4 65
  • Service 22DID D465
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Automatic restart request from body control module VAUXHALLOPEL_AUTOMATIC_RESTART_REQ_BSI

  • Request22 D7 0A
  • Service 22DID D70A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Automatic restart request from engine management computer VAUXHALLOPEL_AUTOMATIC_RESTART

  • Request22 D7 09
  • Service 22DID D709
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Automatic stop allowed by body control module VAUXHALLOPEL_AUTOMATIC_STOP

  • Request22 D7 03
  • Service 22DID D703
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Automatic stop allowed by power steering computer VAUXHALLOPEL_AUTOMATIC_STOP_ALLOWED_POWER_STEER

  • Request22 D7 05
  • Service 22DID D705
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Automatic transmission fluid temperature VAUXHALLOPEL_ATF_T_3RDGEN

  • Request21 18
  • Service 21PID 18
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 40)
Range
-40 to 983.9843 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Auxiliary heater 2 control VAUXHALLOPEL_AUXILIARY_HEATER_2

  • Request22 D4 17
  • Service 22DID D417
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Average mileage for the last 10 regenerations VAUXHALLOPEL_AVG_MILEAGE_LAST_10

  • Request22 D5 25
  • Service 22DID D525
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 16)
Range
0 to 4095 km
Unit
km

In testing for 2011 to 2015, 2017 to 2019.

Barometric pressure VAUXHALLOPEL_BAROMETRIC_P

  • Request22 01 09
  • Service 22DID 0109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 2011 to 2015, 2017 to 2019.

Boost air temperature VAUXHALLOPEL_BOOST_AIR_T

  • Request22 D4 11
  • Service 22DID D411
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Boost pressure VAUXHALLOPEL_BOOST_P

  • Request22 A0 54
  • Service 22DID A054
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 435)
Range
0 to 150 psi
Unit
psi

In testing for 2011 to 2015, 2017 to 2019.

Boost pressure estimate VAUXHALLOPEL_BOOST_P_ESTIMATE

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 441)
Range
0 to 148 psi
Unit
psi

In testing for 2011 to 2015, 2017 to 2019.

Button state VAUXHALLOPEL_BUTTON_ST

  • Request22 D5 17
  • Service 22DID D517
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Cam crank difference VAUXHALLOPEL_CAM_CRANK_DIFF

  • Request22 05 9E
  • Service 22DID 059E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 2011 to 2015, 2017 to 2019.

Camshaft/crankshaft position synchronization VAUXHALLOPEL_CAM_CRANK_POS

  • Request22 D4 18
  • Service 22DID D418
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Catalyst modeled temperature VAUXHALLOPEL_CAT_MODEL_T

  • Request22 01 2B
  • Service 22DID 012B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

CHANGE REPORT IN PROGRESS VAUXHALLOPEL_CHANGE_REPORT

  • Request22 D5 16
  • Service 22DID D516
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Closed loop soot load assessment of the diesel particulate filter VAUXHALLOPEL_CLOSED_LOOP_SOOT

  • Request22 D5 4B
  • Service 22DID D54B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.99 g/L
Unit
g/L

In testing for 2011 to 2015, 2017 to 2019.

Combustion engine state VAUXHALLOPEL_ICE_ST

  • Request22 D7 09
  • Service 22DID D709
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Commanded oil pressure VAUXHALLOPEL_CMD_OIL_P

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Commanded power VAUXHALLOPEL_CMD_POWER

  • Request22 19 97
  • Service 22DID 1997
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Computer lock VAUXHALLOPEL_COMPUTER_LOCK

  • Request22 DA DD
  • Service 22DID DADD
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Computer remote wake-up state VAUXHALLOPEL_COMPUTER_WAKE_UP_ST

  • Request22 D5 15
  • Service 22DID D515
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Computer restarts since memory erase VAUXHALLOPEL_CNT_NUM_RE

  • Request22 D4 D8
  • Service 22DID D4D8
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Computer temperature VAUXHALLOPEL_COMPUTER_T

  • Request22 D4 35
  • Service 22DID D435
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Control current of electromagnetic valve for changing the pressure in the brake system B2 VAUXHALLOPEL_CTRL_CURRENT_P_B2

  • Request22 D6 22
  • Service 22DID D622
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2011 to 2015, 2017 to 2019.

Control current of the electromagnetic valve for changing the pressure in the brake system B1 VAUXHALLOPEL_CTRL_CURRENT_P_B1

  • Request22 D6 08
  • Service 22DID D608
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2011 to 2015, 2017 to 2019.

Controlled air supply module VAUXHALLOPEL_CONTROLLED_AIR_SUP

  • Request22 D4 A0
  • Service 22DID D4A0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Coolant temperature VAUXHALLOPEL_ECT_6A8

Pelican can show this parameter as the engine coolant temperature.

  • Request22 D4 15
  • Service 22DID D415
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Coolant temperature VAUXHALLOPEL_ECT_ECU

  • Request22 10 03
  • Service 22DID 1003
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Coolant temperature VAUXHALLOPEL_ECT_V2

Pelican can show this parameter as the engine coolant temperature.

  • Request22 D8 FB
  • Service 22DID D8FB
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Coolant temperature target VAUXHALLOPEL_ECT_TGT

  • Request22 D4 0D
  • Service 22DID D40D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Coolant temperature, corrected VAUXHALLOPEL_ECT_CORRECTED

  • Request22 D4 0A
  • Service 22DID D40A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Crankcase differential pressure VAUXHALLOPEL_CRANKCASE_DIFF_P

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Crankcase pressure VAUXHALLOPEL_CRANKCASE_P

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1761)
Range
0 to 37.21 psi
Unit
psi

In testing for 2011 to 2015, 2017 to 2019.

Cruise control, RW status VAUXHALLOPEL_CRUISE_CTRL_RW_STAT

  • Request22 D4 B0
  • Service 22DID D4B0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Cylinder 1 injector flow correction VAUXHALLOPEL_CYL_1_INJ_FLOW_CORR

  • Request22 D5 46
  • Service 22DID D546
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Cylinder 2 injector flow correction VAUXHALLOPEL_CYL_2_INJ_FLOW_CORR

  • Request22 D5 47
  • Service 22DID D547
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Cylinder 3 injector flow correction VAUXHALLOPEL_CYL_3_INJ_FLOW_CORR

  • Request22 D5 48
  • Service 22DID D548
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Cylinder 4 injector flow correction VAUXHALLOPEL_CYL_4_INJ_FLOW_CORR

  • Request22 D5 49
  • Service 22DID D549
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Date VAUXHALLOPEL_DATE

  • Request22 D4 CA
  • Service 22DID D4CA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 s
Unit
s

In testing for 2011 to 2015, 2017 to 2019.

DEF dosing rate, gph VAUXHALLOPEL_DEF_DOSING_RATE_GPH

  • Request22 A1 29
  • Service 22DID A129
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

DEF level VAUXHALLOPEL_DEF_LEVEL

  • Request22 A0 06
  • Service 22DID A006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

DEF quality VAUXHALLOPEL_DEF_QUALITY

  • Request22 A1 2B
  • Service 22DID A12B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

DEF temperature VAUXHALLOPEL_DEF_T

  • Request22 A0 04
  • Service 22DID A004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Diesel fuel temperature VAUXHALLOPEL_FUEL_TEMP

  • Request22 19 00
  • Service 22DID 1900
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter delta pressure VAUXHALLOPEL_DPF_DELTA_P

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 73 ÷ 500)
Range
0 to 37.2299 psi
Unit
psi

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter differential pressure VAUXHALLOPEL_DPF_DIFF_P

  • Request22 18 E2
  • Service 22DID 18E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 32768)
Range
-32768 to -26214.5
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter differential pressure sensor signal deviation from reference value VAUXHALLOPEL_DPF_DIFF_P_SENS_SIG

  • Request22 D5 18
  • Service 22DID D518
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter flow resistance VAUXHALLOPEL_DPF_FLOW_RES_V2

  • Request22 01 E2
  • Service 22DID 01E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10000)
Range
-3.2768 to 3.2767
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter inlet gas temperature VAUXHALLOPEL_INLET_DPF_GAS_T

  • Request22 18 DE
  • Service 22DID 18DE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.019608 − 40)
Range
-40 to 1245.0102 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter regen active VAUXHALLOPEL_DPF_REGEN_ACTIVE_7E0

  • Request21 D8
  • Service 21PID D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 79 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter regeneration VAUXHALLOPEL_DPF_REGEN

  • Request21 48
  • Service 21PID 48
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 383 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter regeneration status VAUXHALLOPEL_DPF_REGEN_STAT

  • Request22 D5 21
  • Service 22DID D521
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter soot load VAUXHALLOPEL_DPF_SOOT_LOAD

  • Request22 01 E2
  • Service 22DID 01E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 g/L
Unit
g/L

In testing for 2011 to 2015, 2017 to 2019.

Diesel particulate filter soot mass VAUXHALLOPEL_DPF_SOOT_MASS

  • Request22 18 E4
  • Service 22DID 18E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 763 ÷ 50000)
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Differential pressure at particulate filter VAUXHALLOPEL_DIFF_P_PF

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Drive motor coolant inlet temperature VAUXHALLOPEL_DRIVE_MOTOR_CLT_T

  • Request22 D8 D6
  • Service 22DID D8D6
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor coolant inlet temperature VAUXHALLOPEL_EMOTOR_CLT_INLET_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor coolant outlet temperature VAUXHALLOPEL_EMOTOR_CLT_OUTLET_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor inverter temperature 0 VAUXHALLOPEL_EMOTOR_INVERTER_T_0

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor inverter temperature 1 VAUXHALLOPEL_EMOTOR_INVERTER_T_1

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor inverter temperature 2 VAUXHALLOPEL_EMOTOR_INVERTER_T_2

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor inverter temperature model VAUXHALLOPEL_EMOTOR_INVERTER_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor PCB temperature VAUXHALLOPEL_EMOTOR_PCB_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor power VAUXHALLOPEL_DRIVE_MOTOR_POWER

  • Request22 D8 D9
  • Service 22DID D8D9
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100)
Range
-3276800 to 3276700 W
Unit
W

In testing for 2011 to 2015, 2017 to 2019.

Drive motor rotor temperature VAUXHALLOPEL_EMOTOR_ROTOR_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor stator temperature VAUXHALLOPEL_DRIVE_MOTOR_STATOR_T

  • Request22 D8 CD
  • Service 22DID D8CD
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor stator temperature VAUXHALLOPEL_EMOTOR_STATOR_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Drive motor torque achieved VAUXHALLOPEL_EMOTOR_TQ_ACHIEVED

  • Request22 30 64
  • Service 22DID 3064
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Drive motor torque limit VAUXHALLOPEL_EMOTOR_TQ_LIM

  • Request22 30 63
  • Service 22DID 3063
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Drive motor torque, actual VAUXHALLOPEL_DRIVE_MOTOR_TQ_ACT

  • Request22 D8 D0
  • Service 22DID D8D0
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Drive motor torque, commanded VAUXHALLOPEL_EMOTOR_TQ_CMD

  • Request22 30 64
  • Service 22DID 3064
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Drive motor torque, desired VAUXHALLOPEL_DRIVE_MOTOR_TQ_DES

  • Request22 D8 80
  • Service 22DID D880
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Driver presence VAUXHALLOPEL_DRIVER_PRESENCE

  • Request22 D7 23
  • Service 22DID D723
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Driver, requested torque value VAUXHALLOPEL_DRIVER_REQ_TQ

  • Request22 D5 07
  • Service 22DID D507
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Economy mode off state VAUXHALLOPEL_ECO_MODE_OFF_ST

  • Request22 D7 24
  • Service 22DID D724
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Electric A/C compressor HV current VAUXHALLOPEL_EAC_HV_CURRENT

  • Request22 40 11
  • Service 22DID 4011
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 A
Unit
A

In testing for 2011 to 2015, 2017 to 2019.

Electric cooling fan control VAUXHALLOPEL_GMV_ELEC_COOLING_FAN

  • Request22 D4 2F
  • Service 22DID D42F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Electric machine torque VAUXHALLOPEL_ELEC_MACHINE_TQ

  • Request22 DC B6
  • Service 22DID DCB6
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 1638.3)
Range
-1638 to 4915 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Electric machine torque reduction VAUXHALLOPEL_ELEC_MACHINE_TQ_REDUCTION

  • Request22 DC 69
  • Service 22DID DC69
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Energy accumulator state transfer VAUXHALLOPEL_ENERGY_ACCUMULATOR_ST

  • Request22 D7 55
  • Service 22DID D755
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Energy accumulator temperature limiter state VAUXHALLOPEL_ENERGY_ACCUMULATOR_T

  • Request22 D7 58
  • Service 22DID D758
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine control module status VAUXHALLOPEL_ENG_CTRL_MODULE_STAT

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine coolant temperature VAUXHALLOPEL_ECT

  • Request22 01 1D
  • Service 22DID 011D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Engine coolant temperature VAUXHALLOPEL_ECT_6A9

  • Request22 D5 55
  • Service 22DID D555
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Engine oil degradation VAUXHALLOPEL_OIL_DEGRAD

  • Request22 38 13
  • Service 22DID 3813
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Engine oil dilution protection status VAUXHALLOPEL_ENG_OIL_DILUTION

  • Request22 D5 24
  • Service 22DID D524
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine oil pressure VAUXHALLOPEL_EOP

  • Request22 02 2A
  • Service 22DID 022A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 29 ÷ 50)
Range
0 to 147.8999 psi
Unit
psi

In testing for 2011 to 2015, 2017 to 2019.

Engine oil temperature VAUXHALLOPEL_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549.94 to 3003.56 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Engine oil temperature VAUXHALLOPEL_EOT_212D

Pelican can show this parameter as the engine oil temperature.

  • Request21 2D
  • Service 21PID 2D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 83)
Range
-83 to 376 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Engine oil temperature VAUXHALLOPEL_EOT_21D2

Pelican can show this parameter as the engine oil temperature.

  • Request21 D2
  • Service 21PID D2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Engine oil temperature VAUXHALLOPEL_EOT_V2

  • Request21 2D
  • Service 21PID 2D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Engine operating mode VAUXHALLOPEL_ENG_OP_MODE

  • Request22 D5 53
  • Service 22DID D553
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8)
Range
0 to 8191 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2019.

Engine operational status VAUXHALLOPEL_ENGINE_STATUS

  • Request22 10 02
  • Service 22DID 1002
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine restart counter VAUXHALLOPEL_ENG_RESTART_CNT

  • Request22 D4 06
  • Service 22DID D406
  • Module6A9 → 689
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine restart counter by stop and start function VAUXHALLOPEL_ENG_RESTART_CNT_STOP

  • Request22 D7 1B
  • Service 22DID D71B
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine restart request sent by ESP computer VAUXHALLOPEL_ENG_RESTART_REQ_SENT

  • Request22 D7 0D
  • Service 22DID D70D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine RPM VAUXHALLOPEL_RPM

  • Request22 10 00
  • Service 22DID 1000
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2019.

Engine stalls VAUXHALLOPEL_ENG_STALLS

  • Request22 D7 30
  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine start prohibition control, start lock VAUXHALLOPEL_ENG_START

  • Request22 D7 03
  • Service 22DID D703
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Engine stop time VAUXHALLOPEL_ENG_STOP_TIME

  • Request22 D4 77
  • Service 22DID D477
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

In testing for 2011 to 2015, 2017 to 2019.

Engine temperature VAUXHALLOPEL_ENG_TEMEPRATURE

  • Request22 01 98
  • Service 22DID 0198
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Engine torque VAUXHALLOPEL_ENG_TQ

  • Request21 C3
  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Estimated soot removal time VAUXHALLOPEL_ESITMATED_SOOT

  • Request21 57
  • Service 21PID 57
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2011 to 2015, 2017 to 2019.

Estimated torque of internal friction of the engine VAUXHALLOPEL_ESTIMATED_TQ

  • Request22 D4 E2
  • Service 22DID D4E2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Evaluation of carbon content in engine oil VAUXHALLOPEL_EVALUATION_CARBON

  • Request22 D5 23
  • Service 22DID D523
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 32)
Range
0 to 7.96 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Evaluation of the degree of dilution of motor oil VAUXHALLOPEL_EVALUATION_DEGREE

  • Request22 D5 1F
  • Service 22DID D51F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Evaluation of the exhaust gas flow using the nox sensor VAUXHALLOPEL_EVALUATION_EXH_GAS

  • Request22 D5 42
  • Service 22DID D542
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val × 100)
Range
-214748364800 to 214748364700 L
Unit
L

In testing for 2011 to 2015, 2017 to 2019.

Exhaust camshaft 1 to crankshaft offset VAUXHALLOPEL_EXH_CAM_1_OFFSET

  • Request22 06 1B
  • Service 22DID 061B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas flow through the particulate filter VAUXHALLOPEL_EXH_GAS_FLOW_THROUGH

  • Request22 D5 33
  • Service 22DID D533
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 219.726593)
Range
0 to 14399782 L
Unit
L

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas pressure at the outlet of the particulate filter VAUXHALLOPEL_EXH_GAS_P_OUTLET_PF

  • Request22 D5 44
  • Service 22DID D544
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 999.9999525)
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation airflow control valve position VAUXHALLOPEL_EGR_AIRFLOW_CTRL_VLV

  • Request21 D7
  • Service 21PID D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 39 ÷ 5000)
Range
0 to 511 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation cooler downstream temperature VAUXHALLOPEL_EGR_COOLER_T

  • Request22 39 17
  • Service 22DID 3917
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 900 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation flow VAUXHALLOPEL_EGR_FLOW

  • Request21 D9
  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 kg/h
Unit
kg/h

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation high limit electronic loading VAUXHALLOPEL_EGR_HIGH_LIM

  • Request22 D5 53
  • Service 22DID D553
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation low limit electronic loading VAUXHALLOPEL_EGR_LOW_LIM

  • Request22 D5 52
  • Service 22DID D552
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation orifice temperature VAUXHALLOPEL_EGR_ORIFICE_T

  • Request21 D9
  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val × 9 ÷ 20 + 32)
Range
0 to 29522 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation temperature VAUXHALLOPEL_EGR_T

  • Request22 A0 DC
  • Service 22DID A0DC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 9 ÷ 640)
Range
0 to 921 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation valve duty cycle VAUXHALLOPEL_EGR_VLV_CTRL_SIG_RCO

  • Request22 D5 11
  • Service 22DID D511
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation valve first electronic loading VAUXHALLOPEL_EGR_VLV_FIRST

  • Request22 D5 3A
  • Service 22DID D53A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation valve position VAUXHALLOPEL_EGR_VLV_POS

  • Request22 A0 DA
  • Service 22DID A0DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation valve position VAUXHALLOPEL_EGR_VLV_POS_V2

  • Request22 D5 09
  • Service 22DID D509
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation valve set position VAUXHALLOPEL_EGR_VLV_SET_POS

  • Request22 D5 10
  • Service 22DID D510
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas recirculation valve, commanded position VAUXHALLOPEL_EGR_VLV_CMD_POSTIION

  • Request21 D9
  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 + 32)
Range
0 to 543 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 1 VAUXHALLOPEL_EXH_GAS_T_1

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 144 ÷ 5 + 32)
Range
0 to 7376 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 1 VAUXHALLOPEL_EXH_GAS_T_1_7E0

  • Request21 48
  • Service 21PID 48
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 1 – DOC inlet VAUXHALLOPEL_EXH_GAS_T_1_DOC

  • Request22 A0 BD
  • Service 22DID A0BD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 2 VAUXHALLOPEL_EXH_GAS_T_2

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 9 ÷ 80 + 32)
Range
0 to 7404 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 2 VAUXHALLOPEL_EXH_GAS_T_2_7E0

  • Request21 48
  • Service 21PID 48
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 2 – DOC outlet VAUXHALLOPEL_EXH_GAS_T_2_DOC

  • Request22 A0 C2
  • Service 22DID A0C2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 3 VAUXHALLOPEL_EXH_GAS_T_3

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 9 ÷ 80 + 32)
Range
0 to 7404 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 3 – DPF outlet VAUXHALLOPEL_EXH_GAS_T_3_DPF

  • Request22 A0 C4
  • Service 22DID A0C4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 4 VAUXHALLOPEL_EXH_GAS_T_4

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val × 9 ÷ 80 + 32)
Range
0 to 7404 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 4, catalyst middle VAUXHALLOPEL_EXH_GAS_T_4_SCR_CAT

  • Request22 A0 C6
  • Service 22DID A0C6
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust gas temperature 5 – SCR CAT outlet VAUXHALLOPEL_EXH_GAS_T_5_SCR_CAT

  • Request22 A0 C8
  • Service 22DID A0C8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Exhaust temperature, downstream of exhaust manifold VAUXHALLOPEL_EXH_T_DN_EXH

  • Request22 01 7E
  • Service 22DID 017E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549.94 to 3003.56 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Exhaust temperature, EGR cooler downstream VAUXHALLOPEL_EXH_T_EGR_COOLER_DN

  • Request22 01 7E
  • Service 22DID 017E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549.94 to 3003.56 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Exhaust temperature, upstream of exhaust manifold VAUXHALLOPEL_EXH_T_UP_EXH

  • Request22 01 7E
  • Service 22DID 017E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549.94 to 3003.56 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Expected generator supplier identifier of the reversible generator VAUXHALLOPEL_EXPECTED_GEN

  • Request22 D7 89
  • Service 22DID D789
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Expected identifier of electronic power circuit of reversible generator generator VAUXHALLOPEL_EXPECTED_IDENTIFIER_ELECTRONIC

  • Request22 D7 88
  • Service 22DID D788
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Expected identifier of reversible generator VAUXHALLOPEL_EXPECTED_IDENTIFIER

  • Request22 D7 87
  • Service 22DID D787
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Fuel correction cylinder 1 VAUXHALLOPEL_FUEL_CORR_CYL1

  • Request22 38 00
  • Service 22DID 3800
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2011 to 2015, 2017 to 2019.

Fuel correction cylinder 2 VAUXHALLOPEL_FUEL_CORR_CYL2

  • Request22 38 01
  • Service 22DID 3801
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2011 to 2015, 2017 to 2019.

Fuel correction cylinder 3 VAUXHALLOPEL_FUEL_CORR_CYL3

  • Request22 38 02
  • Service 22DID 3802
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2011 to 2015, 2017 to 2019.

Fuel correction cylinder 4 VAUXHALLOPEL_FUEL_CORR_CYL4

  • Request22 38 03
  • Service 22DID 3803
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2011 to 2015, 2017 to 2019.

Fuel rail pressure commanded VAUXHALLOPEL_RAIL_PRESS_CMD

  • Request22 19 46
  • Service 22DID 1946
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3000 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Fuel rail pressure measured VAUXHALLOPEL_RAIL_PRESS

  • Request22 19 47
  • Service 22DID 1947
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3000 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

FUGITIVE TRIP IN EMERGENCY MODE VAUXHALLOPEL_FUGITIVE_TRIP

  • Request22 D6 71
  • Service 22DID D671
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Generator mode VAUXHALLOPEL_GEN_MODE

  • Request22 D7 14
  • Service 22DID D714
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 75)
Range
0 to 19125 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2019.

Generator shutdown VAUXHALLOPEL_GEN_SHUTDOWN

  • Request22 D7 5B
  • Service 22DID D75B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Glow plug plug set temperature VAUXHALLOPEL_PREHEATING_T

  • Request22 D5 0F
  • Service 22DID D50F
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Glow plug relay status VAUXHALLOPEL_STAT_PRE_POST

  • Request22 D5 0D
  • Service 22DID D50D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

IAT post-intercooler VAUXHALLOPEL_IAT_TURBO

  • Request22 19 35
  • Service 22DID 1935
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Identifier of the electronic power circuit of the reversible generator VAUXHALLOPEL_IDENTIFIER

  • Request22 D7 32
  • Service 22DID D732
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Identifier of the supplier of the reversible generator VAUXHALLOPEL_IDENTIFIER_SUPPLIER

  • Request22 D7 33
  • Service 22DID D733
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Immobilizer code programming status VAUXHALLOPEL_IMMOBILIZER_CODE

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Indicated engine torque VAUXHALLOPEL_INDICATED_ENG_TQ

  • Request22 D4 D2
  • Service 22DID D4D2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Injection pulse, cylinder 1 VAUXHALLOPEL_INJ_CYL_1

  • Request22 02 34
  • Service 22DID 0234
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Injection pulse, cylinder 2 VAUXHALLOPEL_INJ_CYL_2

  • Request22 02 35
  • Service 22DID 0235
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Injection pulse, cylinder 3 VAUXHALLOPEL_INJ_CYL_3

  • Request22 02 36
  • Service 22DID 0236
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Injection pulse, cylinder 4 VAUXHALLOPEL_INJ_CYL_4

  • Request22 02 37
  • Service 22DID 0237
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Injector code 1 VAUXHALLOPEL_INJ_CODE_1

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 47 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Injector code 2 VAUXHALLOPEL_INJ_CODE_2

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 72 to 111 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Injector code 3 VAUXHALLOPEL_INJ_CODE_3

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 136 to 175 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Injector code 4 VAUXHALLOPEL_INJ_CODE_4

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 200 to 239 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Injector pulse width, cylinder 1 VAUXHALLOPEL_INJ_WIDTH_CYL_1

  • Request22 02 34
  • Service 22DID 0234
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2011 to 2015, 2017 to 2019.

Injector pulse width, cylinder 2 VAUXHALLOPEL_INJ_WIDTH_CYL_2

  • Request22 02 35
  • Service 22DID 0235
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2011 to 2015, 2017 to 2019.

Injector pulse width, cylinder 3 VAUXHALLOPEL_INJ_WIDTH_CYL_3

  • Request22 02 36
  • Service 22DID 0236
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2011 to 2015, 2017 to 2019.

Injector pulse width, cylinder 4 VAUXHALLOPEL_INJ_WIDTH_CYL_4

  • Request22 02 37
  • Service 22DID 0237
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2011 to 2015, 2017 to 2019.

Intake camshaft 1 to crankshaft offset VAUXHALLOPEL_INT_CAM_1_OFFSET

  • Request22 06 C2
  • Service 22DID 06C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2011 to 2015, 2017 to 2019.

Intake manifold air pressure VAUXHALLOPEL_MAP

  • Request22 01 74
  • Service 22DID 0174
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 2011 to 2015, 2017 to 2019.

Intake manifold air temperature VAUXHALLOPEL_IAT_01FF

  • Request22 01 FF
  • Service 22DID 01FF
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Intake manifold air temperature VAUXHALLOPEL_IAT_70B8

  • Request22 70 B8
  • Service 22DID 70B8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0198412698 − 40)
Range
-40 to 1260.2976 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Intake manifold air temperature VAUXHALLOPEL_INT_MANIFOLD_AIR_T

  • Request22 19 35
  • Service 22DID 1935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 40)
Range
-40 to 65495 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Inverter temperature estimated VAUXHALLOPEL_INVERTER_T_ESTIMATED

  • Request22 DC 6A
  • Service 22DID DC6A
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Inverter temperature, commanded VAUXHALLOPEL_INVERTER_T_CMD

  • Request22 DC 04
  • Service 22DID DC04
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Knock sensor 1 VAUXHALLOPEL_KNOCK_SENS_1

  • Request22 01 A9
  • Service 22DID 01A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 2011 to 2015, 2017 to 2019.

Knock sensor 2 VAUXHALLOPEL_KNOCK_SENS_2

  • Request22 01 AA
  • Service 22DID 01AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 2011 to 2015, 2017 to 2019.

Line pressure VAUXHALLOPEL_LINE_P

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2011 to 2015, 2017 to 2019.

Line pressure duty cycle VAUXHALLOPEL_LINE_P_DUTY

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 655)
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Line pressure solenoid valve control current VAUXHALLOPEL_SLT_LINE_P_VARIATION

  • Request22 D6 06
  • Service 22DID D606
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2011 to 2015, 2017 to 2019.

Lock status VAUXHALLOPEL_LOCK_STAT

  • Request22 DA DD
  • Service 22DID DADD
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Long-term regeneration capability VAUXHALLOPEL_LONG_TERM_REGEN

  • Request22 D5 4D
  • Service 22DID D54D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Low side coolant temperature VAUXHALLOPEL_LOW_SIDE_ECT

  • Request22 12 C9
  • Service 22DID 12C9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

M-Prop injection command VAUXHALLOPEL_MPROP_CMD

  • Request22 18 D0
  • Service 22DID 18D0
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Mass airflow sensor temperature VAUXHALLOPEL_MAF_TEMP

  • Request22 19 3F
  • Service 22DID 193F
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Mass of urea injected for thermal protection of urea injector VAUXHALLOPEL_MASS_UREA_INJECTED

  • Request22 D5 6B
  • Service 22DID D56B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50.00000112)
Range
0 to 1310 g
Unit
g

In testing for 2011 to 2015, 2017 to 2019.

Maximum allowable torque VAUXHALLOPEL_MAX_ALLOWABLE_TQ

  • Request22 D5 06
  • Service 22DID D506
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Measured current of electromagnetic valve for changing the pressure in the brake system B2 VAUXHALLOPEL_MEAS_CURRENT_P_B2

  • Request22 D6 23
  • Service 22DID D623
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2011 to 2015, 2017 to 2019.

Measured current of the electromagnetic valve for changing the pressure in the brake system B1 VAUXHALLOPEL_MEAS_CURRENT_P_B1

  • Request22 D6 09
  • Service 22DID D609
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2011 to 2015, 2017 to 2019.

Measured line pressure variation solenoid valve current VAUXHALLOPEL_MEAS_LINE_P

  • Request22 D6 07
  • Service 22DID D607
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2011 to 2015, 2017 to 2019.

Mileage remaining before diesel particulate filter replacement VAUXHALLOPEL_MILEAGE_REMAINING

  • Request22 D5 30
  • Service 22DID D530
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 16)
Range
-524288 to 524272 km
Unit
km

In testing for 2011 to 2015, 2017 to 2019.

Mileage since last diesel particulate filter replacement VAUXHALLOPEL_MILEAGE_SINCE_DPF

  • Request22 D5 31
  • Service 22DID D531
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8)
Range
0 to 524280 km
Unit
km

In testing for 2011 to 2015, 2017 to 2019.

Mileage since last oil change VAUXHALLOPEL_MILEAGE_SINCE_OIL

  • Request22 D4 3F
  • Service 22DID D43F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2011 to 2015, 2017 to 2019.

Minimum cell capacity VAUXHALLOPEL_MIN_CELL_CAP

  • Request22 D4 13
  • Service 22DID D413
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Mixture enrichment measured by nox sensor at inlet VAUXHALLOPEL_MIXTURE_ENRICHMENT

  • Request22 D5 71
  • Service 22DID D571
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Mixture enrichment measured by nox sensor at outlet VAUXHALLOPEL_MIXTURE_ENRICHMENT_MEAS

  • Request22 D5 5B
  • Service 22DID D55B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Movement of controlled air supply module VAUXHALLOPEL_MOVEMENT_CONTROLLED

  • Request22 D4 EB
  • Service 22DID D4EB
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Multi-displacement system active VAUXHALLOPEL_MDS_ACTIVE

  • Request22 0E CA
  • Service 22DID 0ECA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2019.

Neutral position sensor status VAUXHALLOPEL_NEUTRAL_POS_SENS

  • Request22 D4 38
  • Service 22DID D438
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Nitrogen oxides at exhaust treatment intake VAUXHALLOPEL_AFTERTREATMENT_INT

  • Request22 A1 14
  • Service 22DID A114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Nitrogen oxides at exhaust treatment outlet VAUXHALLOPEL_AFTERTREATMENT

  • Request22 A1 1A
  • Service 22DID A11A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Nox sensor heating control VAUXHALLOPEL_NOX_SENS_HEATING

  • Request22 D5 54
  • Service 22DID D554
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Nox sensor signal status at the inlet VAUXHALLOPEL_NOX_SENS_SIG_STAT_INLET

  • Request22 D5 72
  • Service 22DID D572
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Nox sensor signal status at the outlet VAUXHALLOPEL_NOX_SENS_SIG_STAT

  • Request22 D5 73
  • Service 22DID D573
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Nox system operating status VAUXHALLOPEL_NOX_SYSTEM_OP_STAT

  • Request22 D5 40
  • Service 22DID D540
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Number of engine stop information deletion cycles VAUXHALLOPEL_NUM_ENG_STOP

  • Request22 D7 30
  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Oil pressure VAUXHALLOPEL_OIL_P

  • Request22 D4 29
  • Service 22DID D429
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Oil pressure reference value VAUXHALLOPEL_OIL_P_REFERENCE

  • Request22 D4 64
  • Service 22DID D464
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Oil pressure regulation control VAUXHALLOPEL_OIL_P_REGULATION

  • Request22 D4 3B
  • Service 22DID D43B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Oil temperature VAUXHALLOPEL_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request22 D4 7D
  • Service 22DID D47D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Oil temperature VAUXHALLOPEL_OIL_TEMEPRATURE

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Open loop soot load assessment of the diesel particulate filter VAUXHALLOPEL_OPEN_LOOP_SOOT_LOAD

  • Request22 D5 4A
  • Service 22DID D54A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1024)
Range
0 to 63.99 g/L
Unit
g/L

In testing for 2011 to 2015, 2017 to 2019.

Outside air temperature VAUXHALLOPEL_AAT_6A8

  • Request22 D4 14
  • Service 22DID D414
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Particulate filter differential pressure VAUXHALLOPEL_PF_DIFF_P

  • Request22 D5 20
  • Service 22DID D520
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Particulate filter regeneration count VAUXHALLOPEL_DPF_REGENS_5089

  • Request22 50 89
  • Service 22DID 5089
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Power consumed for heating the pipelines of the urea injection system VAUXHALLOPEL_POWER_CONSUMED

  • Request22 D5 80
  • Service 22DID D580
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Power spent on heating the urea injection system pipes, percentage ratio VAUXHALLOPEL_POWER_SPENT_ON

  • Request22 D5 3C
  • Service 22DID D53C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 163.8399875)
Range
0 to 399 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Powertrain condition VAUXHALLOPEL_POWERTRAIN_COND

  • Request22 D4 BA
  • Service 22DID D4BA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Preheating relay control VAUXHALLOPEL_PREHEATING_RELAY

  • Request22 D5 0C
  • Service 22DID D50C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Presence of the identifier of the reversible generator VAUXHALLOPEL_PRESENCE_IDENTIFIER

  • Request22 D7 31
  • Service 22DID D731
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Pressure in the particulate filter VAUXHALLOPEL_P_PF

  • Request22 01 7B
  • Service 22DID 017B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Pressure-based injection permission for urea solution VAUXHALLOPEL_P_BASED_INJ

  • Request22 D5 14
  • Service 22DID D514
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Problems detected while transmitting unlock code VAUXHALLOPEL_PROBLEMS_DETECTED

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Problems detected while transmitting unlock code VAUXHALLOPEL_PROBLEMS_DETECTED_WHILE

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Real engine torque VAUXHALLOPEL_REAL_ENG_TQ

  • Request22 D5 54
  • Service 22DID D554
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Regen enable, on/off – alternative VAUXHALLOPEL_REGEN_ENABLE_ON_OFF

  • Request21 D8
  • Service 21PID D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 95 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2019.

Regeneration active VAUXHALLOPEL_DPF_REGEN_ACTIVE

  • Request22 50 AF
  • Service 22DID 50AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Regeneration enable VAUXHALLOPEL_REGEN_ENABLE

  • Request22 D5 28
  • Service 22DID D528
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Remaining urea solution in the urea tank VAUXHALLOPEL_REMAINING_UREA

  • Request22 D5 17
  • Service 22DID D517
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 125 ÷ 128)
Range
0 to 63999
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Remote wake-up circuit status VAUXHALLOPEL_REMOTE_WAKE_UP

  • Request22 D7 05
  • Service 22DID D705
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Remote wake-up state VAUXHALLOPEL_REMOTE_WAKE_UP_ST

  • Request22 D7 08
  • Service 22DID D708
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Request to turn on the engine diagnostic indicator VAUXHALLOPEL_REQ_TURN_ON_ENG

  • Request22 D5 11
  • Service 22DID D511
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Requested value controlled thermostat VAUXHALLOPEL_REQ_CONTROLLED

  • Request22 D5 86
  • Service 22DID D586
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 81.92000625)
Range
-399 to 399 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Restart request sent by power steering computer VAUXHALLOPEL_RESTART_REQ_SENT

  • Request22 D7 0C
  • Service 22DID D70C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Restart request sent by suspension computer VAUXHALLOPEL_RESTART_REQ_SENT_SUSPENSION

  • Request22 D7 0E
  • Service 22DID D70E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Return to engine start and restart control by starter VAUXHALLOPEL_RETURN_ENG_START

  • Request22 D7 64
  • Service 22DID D764
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Return to starter engine restart control VAUXHALLOPEL_RETURN_STARTER_ENG

  • Request22 D7 61
  • Service 22DID D761
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Reverse generator status VAUXHALLOPEL_REVERSE_GEN_STAT

  • Request22 D7 16
  • Service 22DID D716
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Reversible generator torque VAUXHALLOPEL_REVERSIBLE_GEN_TQ

  • Request22 D7 15
  • Service 22DID D715
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Sensed oil pressure VAUXHALLOPEL_SENSED_OIL_P

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Sensed pressure particulate filter downstream VAUXHALLOPEL_SENSED_P_PF_DN

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Service network related engine restart request VAUXHALLOPEL_SERVICE_NETWORK

  • Request22 D7 4B
  • Service 22DID D74B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Short term knock retard VAUXHALLOPEL_SHORT_TERM_KNOCK

  • Request22 01 AE
  • Service 22DID 01AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 °
Unit
°

In testing for 2011 to 2015, 2017 to 2019.

Short-term regeneration capability VAUXHALLOPEL_SHORT_TERM_REGEN

  • Request22 D5 4C
  • Service 22DID D54C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Simulated particulate mass, stored VAUXHALLOPEL_DPF_SIM_MASS

  • Request22 01 E2
  • Service 22DID 01E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Soot clogging level of diesel particulate filter VAUXHALLOPEL_SOOT_CLOGGING_LEVEL

  • Request22 D5 2F
  • Service 22DID D52F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10.24)
Range
0 to 6399 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Soot load VAUXHALLOPEL_SOOT_LOAD

  • Request21 4D
  • Service 21PID 4D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 g
Unit
g

In testing for 2011 to 2015, 2017 to 2019.

Soot load based on delta pressure VAUXHALLOPEL_SOOT_LOAD_BASED_ON_P

  • Request21 57
  • Service 21PID 57
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 100 + 32)
Range
0 to 34.55
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Soot mass flow in exhaust gas after combustion VAUXHALLOPEL_SOOT_MASS_FLOW_EXH

  • Request22 01 7A
  • Service 22DID 017A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 223 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 100)
Range
-21474836 to 21474836
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Soot mass load VAUXHALLOPEL_SOOT_MASS_LOAD

  • Request22 50 8D
  • Service 22DID 508D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 650)
Range
0 to 100.823 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Specified volume of injected urea solution VAUXHALLOPEL_SPEC_VOLUME_INJECTED

  • Request22 D5 50
  • Service 22DID D550
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Sport mode contactor state VAUXHALLOPEL_SPORT_MODE_CONTACTOR

  • Request22 D5 03
  • Service 22DID D503
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Start inhibit control, wired VAUXHALLOPEL_START_INHIBIT_CTRL

  • Request22 D7 67
  • Service 22DID D767
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Start or restart inhibition transmitted by engine management computer VAUXHALLOPEL_START_OR_RESTART

  • Request22 D7 1E
  • Service 22DID D71E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Start prohibition VAUXHALLOPEL_START_PROHIBITION

  • Request22 D5 1B
  • Service 22DID D51B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Starter activation counter VAUXHALLOPEL_STARTER_ACTIVATION

  • Request22 D7 1F
  • Service 22DID D71F
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Starter control interface unit operating status VAUXHALLOPEL_STARTER_CTRL

  • Request22 D7 2A
  • Service 22DID D72A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Starter duty cycle VAUXHALLOPEL_STARTER_DUTY

  • Request22 D4 78
  • Service 22DID D478
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 s
Unit
s

In testing for 2011 to 2015, 2017 to 2019.

Starter engagement status VAUXHALLOPEL_STARTER_ENGAGEMENT

  • Request22 D4 C3
  • Service 22DID D4C3
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

State lock/unlock control unit VAUXHALLOPEL_ST_LOCK_UNLOCK_CTRL

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Status of internal ignition motor VAUXHALLOPEL_STAT_INTERNAL_IGN

  • Request22 D4 12
  • Service 22DID D412
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Status of the energy accumulator VAUXHALLOPEL_STAT_ENERGY

  • Request22 D7 22
  • Service 22DID D722
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Stop allowed by ESP computer VAUXHALLOPEL_STOP_ALLOWED_ESP

  • Request22 D7 06
  • Service 22DID D706
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Stop and start function state VAUXHALLOPEL_STOP_START_FUNCTION

  • Request22 D7 25
  • Service 22DID D725
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Stop and start switch VAUXHALLOPEL_STOP_START_SWITCH

  • Request22 D7 26
  • Service 22DID D726
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Stop permitted by suspension computer VAUXHALLOPEL_STOP_PERMITTED

  • Request22 D7 07
  • Service 22DID D707
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Swirl actuator command VAUXHALLOPEL_SWIRL_CMD

  • Request22 18 9B
  • Service 22DID 189B
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-100 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Temperature before catalyst VAUXHALLOPEL_T_BEFORE_CAT

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273.14 to 6280.36 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Temperature before diesel particulate filter VAUXHALLOPEL_T_BEFORE_DPF

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273.14 to 6280.36 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Temperature before turbine VAUXHALLOPEL_T_BEFORE_TURBINE

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273.14 to 6280.36 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Temperature difference between the hottest and the coolest cells VAUXHALLOPEL_T_DIFF_HOTEST

  • Request22 D8 78
  • Service 22DID D878
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Temperature of the energy accumulator VAUXHALLOPEL_T_ENERGY_ACCUMULATOR

  • Request22 D7 21
  • Service 22DID D721
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Temperature of the urea solution in the urea tank VAUXHALLOPEL_T_UREA_SOLUTION_UREA

  • Request22 D5 6D
  • Service 22DID D56D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

The composition of the mixture is calculated by the oxygen sensor VAUXHALLOPEL_COMPOSITION_MIXTURE

  • Request22 D5 70
  • Service 22DID D570
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Throttle inlet air temperature filtered VAUXHALLOPEL_THROTTLE_INLET_AIR_T

  • Request22 14 B1
  • Service 22DID 14B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Throttle inlet air temperature raw VAUXHALLOPEL_THROTTLE_INLET_AIR_T_RAW

  • Request22 14 B3
  • Service 22DID 14B3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Throttle inlet pressure VAUXHALLOPEL_THROTTLE_INLET_P

  • Request22 12 47
  • Service 22DID 1247
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 160)
Range
0 to 409.5937 kPa
Unit
kPa

In testing for 2011 to 2015, 2017 to 2019.

Time since active regen VAUXHALLOPEL_TIME_SINCE_ACTIVE

  • Request22 A0 03
  • Service 22DID A003
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2011 to 2015, 2017 to 2019.

Time since regen started VAUXHALLOPEL_TIME_SINCE_REGEN

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 40)
Range
0 to 1638 s
Unit
s

In testing for 2011 to 2015, 2017 to 2019.

Torque corresponding to driver requirement VAUXHALLOPEL_TQ_CORRESPONDING

  • Request22 D4 E3
  • Service 22DID D4E3
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Torque supplied or taken by generator VAUXHALLOPEL_TQ_SUPPLIED_OR_TAKEN

  • Request22 D7 28
  • Service 22DID D728
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2019.

Total mass of additive accumulated in the diesel particulate filter VAUXHALLOPEL_TOT_MASS_ADDITIVE

  • Request22 D5 26
  • Service 22DID D526
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 g
Unit
g

In testing for 2011 to 2015, 2017 to 2019.

Total mass of additive accumulated in the diesel particulate filter VAUXHALLOPEL_TOT_MASS_ADDITIVE_ACCUMULATED_DPF

  • Request22 D5 27
  • Service 22DID D527
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047 g
Unit
g

In testing for 2011 to 2015, 2017 to 2019.

Total mileage VAUXHALLOPEL_ODO_6A8

Pelican can show this parameter as the odometer.

  • Request22 D4 9C
  • Service 22DID D49C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2011 to 2015, 2017 to 2019.

Total number of started regeneration events VAUXHALLOPEL_TOT_NUM_STARTED

  • Request22 18 E7
  • Service 22DID 18E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Towing device configured VAUXHALLOPEL_CAN_VEH_BE_EQUIPPED

  • Request22 D5 57
  • Service 22DID D557
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Traction circuit coolant temperature VAUXHALLOPEL_TRACTION_CIRCUIT_ECT

  • Request22 D8 F9
  • Service 22DID D8F9
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Traction or stability control regulating VAUXHALLOPEL_ASR_OR_ESP_SYSTEM

  • Request22 D5 12
  • Service 22DID D512
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Transmission fluid temperature VAUXHALLOPEL_ATF_T_V3

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Turbine upstream temperature VAUXHALLOPEL_TURBINE_UP_T

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273.14 to 6280.36 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Turbo boost pressure VAUXHALLOPEL_BOOST

  • Request22 19 5A
  • Service 22DID 195A
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 3276.8)
Range
-100 to 300 kPa
Unit
kPa

In testing for 2011 to 2015, 2017 to 2019.

Turbo compressor inlet temperature VAUXHALLOPEL_TURBO_COMP_INLET_T

  • Request22 A0 EC
  • Service 22DID A0EC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 36 ÷ 5 + 32)
Range
0 to 1868 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Urea mass fraction VAUXHALLOPEL_UREA_MASS_FRACTION

  • Request22 D5 8C
  • Service 22DID D58C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Urea solution injected amount VAUXHALLOPEL_UREA_SOLUTION

  • Request22 D5 68
  • Service 22DID D568
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Urea solution injection permission based on temperature value VAUXHALLOPEL_UREA_SOLUTION_INJ_ON_T

  • Request22 D5 15
  • Service 22DID D515
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Urea solution pressure VAUXHALLOPEL_UREA_SOLUTION_P

  • Request22 D5 3E
  • Service 22DID D53E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2019.

Urea solution type in urea tank VAUXHALLOPEL_UREA_SOLUTION_TYPE

  • Request22 D5 8D
  • Service 22DID D58D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Urea tank heating current VAUXHALLOPEL_UREA_TANK_HEATING

  • Request22 D5 81
  • Service 22DID D581
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Urea tank heating current, percentage VAUXHALLOPEL_UREA_TANK_HEATING_CURRENT

  • Request22 D5 1E
  • Service 22DID D51E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 163.8399875)
Range
0 to 399 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Vacuum circuit vacuum VAUXHALLOPEL_VACUUM_CIRCUIT

  • Request22 D7 3B
  • Service 22DID D73B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2011 to 2015, 2017 to 2019.

Value during generator load smooth increase VAUXHALLOPEL_DURING_GEN_LOAD

  • Request22 D7 53
  • Service 22DID D753
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Variable geometry turbo actuator, commanded position VAUXHALLOPEL_VGT_CMD_189F

  • Request22 18 9F
  • Service 22DID 189F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 39 ÷ 50 − 100)
Range
-100 to 98.9 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Variable geometry turbo actuator, commanded position VAUXHALLOPEL_VGT_CMD_507B

  • Request22 50 7B
  • Service 22DID 507B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 39 ÷ 50 − 100)
Range
-100 to 98.9 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Variable geometry turbo compressor inlet air temperature VAUXHALLOPEL_VGT_COMP_INLET_AIR_T

  • Request21 DA
  • Service 21PID DA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 9 ÷ 20 + 32)
Range
0 to 29522 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Variable geometry turbo compressor outlet air temperature VAUXHALLOPEL_VGT_COMP_OULET_AIR_T

  • Request21 DA
  • Service 21PID DA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 9 ÷ 20 + 32)
Range
0 to 29522 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2019.

Variable oil pump position VAUXHALLOPEL_OIL_PUMP

  • Request22 19 4F
  • Service 22DID 194F
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Variable valve timing oil pressure VAUXHALLOPEL_VARIABLE_VLV_TIM_OIL_P

  • Request22 06 9E
  • Service 22DID 069E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 kPa
Unit
kPa

In testing for 2011 to 2015, 2017 to 2019.

Variable valve timing oil temperature VAUXHALLOPEL_VARIABLE_VLV_TIM_OIL_T

  • Request22 06 9F
  • Service 22DID 069F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2019.

Vehicle hour meter VAUXHALLOPEL_VEH_HOUR_METER

  • Request22 D8 01
  • Service 22DID D801
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 s
Unit
s

In testing for 2011 to 2015, 2017 to 2019.

Vehicle mileage remaining before filling the tank with urea solution VAUXHALLOPEL_VEH_MILEAGE

  • Request22 D5 13
  • Service 22DID D513
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 km
Unit
km

In testing for 2011 to 2015, 2017 to 2019.

Vehicle mileage since the last oil change under severe vehicle operating conditions VAUXHALLOPEL_VEH_MILEAGE_SINCE

  • Request22 D5 34
  • Service 22DID D534
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 km
Unit
km

In testing for 2011 to 2015, 2017 to 2019.

VGT position actual VAUXHALLOPEL_VGT_ACT

  • Request22 18 A0
  • Service 22DID 18A0
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

VGT position commanded VAUXHALLOPEL_VGT_CMD

  • Request22 18 9F
  • Service 22DID 189F
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2019.

Volume of urea solution measured in urea tank VAUXHALLOPEL_VOLUME_UREA_SOLUTION

  • Request22 D5 58
  • Service 22DID D558
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 L
Unit
L

In testing for 2011 to 2015, 2017 to 2019.

Wastegate position sensor VAUXHALLOPEL_WASTEGATE_POS_SENS

  • Request22 1F 59
  • Service 22DID 1F59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 61 ÷ 12500)
Range
0 to 319.8107 V
Unit
V

In testing for 2011 to 2015, 2017 to 2019.

Water in diesel VAUXHALLOPEL_WATER_DIESEL

  • Request22 D5 2C
  • Service 22DID D52C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Winter mode switch state VAUXHALLOPEL_WINTER_MODE_SWITCH

  • Request22 D5 02
  • Service 22DID D502
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2019.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.