Ambient temperature YCROSS_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2020 to 2021, 2024, 2026

Example reply from a 2025 Toyota Yaris Cross.

Bits 0 to 7 of the reply, 8 bits.

0x2C = 44 → (44 − 40) = 4 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2023, 2025. In testing for 2020 to 2021, 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adjusted ambient temperature YCROSS_ADJUSTED_AMBIENT_T

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Air inlet damper actual pulse YCROSS_AIR_INLET_DAMPER_ACTUAL_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Air inlet damper target pulse YCROSS_AIR_INLET_DAMPER_TARGET_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Air outlet servo actual pulse, driver YCROSS_AIR_OUTLET_SERVO_ACTU_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Air outlet servo pulse, driver YCROSS_AIR_OUTLET_SERVO_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. Supported for 2021 to 2022.

Ambient air temperature YCROSS_AAT_7C4

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Ambient temperature YCROSS_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2020 to 2021, 2024, 2026

Example reply from a 2025 Toyota Yaris Cross.

Bits 0 to 7 of the reply, 8 bits.

0x2C = 44 → (44 − 40) = 4 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2023, 2025. In testing for 2020 to 2021, 2024, 2026.

Ambient temperature, climate YCROSS_AAT_7C4_V2Confirmed

  • Request22 10 02
  • Service 22DID 1002
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Toyota Yaris Cross.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x09FC = 2556 → (2556 ÷ 100) = 25.56 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Blower level YCROSS_BLOWERConfirmed

  • Request22 28 01
  • Service 22DID 2801
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Toyota Yaris Cross.

Bits 0 to 7 of the reply, 8 bits.

0x02 = 2 → 2

Formula
val
Range
0 to 7
Unit
Number

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Blower motor speed level YCROSS_BLOWER_MOTOR_SPEED_LEVEL

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Cabin temperature YCROSS_CABIN_TConfirmed

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Toyota Yaris Cross.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 63.75 ÷ 255 − 6.5) = -6.5 °C

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023.

Cabin temperature YCROSS_CABIN_T_V2Confirmed

  • Request22 10 01
  • Service 22DID 1001
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Toyota Yaris Cross.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0B41 = 2881 → (2881 ÷ 100) = 28.81 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Climate set point code YCROSS_HVAC_SET_RAWConfirmed

  • Request22 10 36
  • Service 22DID 1036
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2020 to 2024, 2026

Example reply from a 2025 Toyota Yaris Cross.

Bits 0 to 7 of the reply, 8 bits.

0x0D = 13 → 13

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2020 to 2024, 2026.

Communication with air conditioner YCROSS_COMM_WITH_AIR_CONDITIONER

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Communication with HV YCROSS_COMMUNICATION_WITH_HV

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Communication with valvematic YCROSS_COMM_WITH_VALVEMATIC_COMM

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Evaporator fin thermistor YCROSS_EVAP_FIN_THERMISTOR

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Evaporator target temperature YCROSS_EVAP_TARGET_T

  • Request21 4C
  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67
Unit
Number

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Set temperature, driver side YCROSS_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Solar sensor, driver side YCROSS_SOLAR_DRIVER

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2021, 2024, 2026. Not supported for 2022 to 2023, 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.