12V battery voltage VENZA_12V_V_V2Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 15 EE
  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 7 of the reply, 8 bits.

0x25 = 37 → (37 × 0.31448 + 0.0125) = 11.64826 V

Formula
(val × 0.31448 + 0.0125)
Range
0 to 80.2 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

1st turbocharger outlet pressure, control valve VENZA_1ST_TRUBOCHARGER_P

  • Request22 11 CD
  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

2nd turbocharger outlet pressure VENZA_2ND_TRUBOCHARGER_OUTLET_P

  • Request22 11 AF
  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

2nd turbocharger outlet pressure, control valve VENZA_2ND_TRUBOCHARGER_P

  • Request22 11 CD
  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

12V battery current VENZA_12V_CConfirmed

  • Request22 15 F7
  • Service 22DID 15F7
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0x7015 = 28693 → (28693 × 38.147 ÷ 10000 − 125) = -15.544813 A

Formula
(val × 38.147 ÷ 10000 − 125)
Range
-125 to 124 A
Unit
A

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

12V battery temperature VENZA_12V_TConfirmed

  • Request22 15 F8
  • Service 22DID 15F8
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0x01AD = 429 → (429 ÷ 10 − 40) = 2.9 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

12V battery voltage VENZA_12V_V_V2Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 15 EE
  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 7 of the reply, 8 bits.

0x25 = 37 → (37 × 0.31448 + 0.0125) = 11.64826 V

Formula
(val × 0.31448 + 0.0125)
Range
0 to 80.2 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

12V battery voltage before system main relay VENZA_12V_BAT_V_BEFORE_SMRConfirmed

  • Request22 10 7E
  • Service 22DID 107E
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 7 of the reply, 8 bits.

0x23 = 35 → (35 × 61 ÷ 50000 + 11.25) = 11.2927 V

Formula
(val × 61 ÷ 50000 + 11.25)
Range
0 to 11.56 V
Unit
V

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

12V battery voltage smoothed VENZA_12V_BAT_V_SMOOTHEDConfirmed

  • Request22 1F 42
  • Service 22DID 1F42
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0x2F6A = 12138 → (12138 ÷ 1000) = 12.138 V

Formula
(val ÷ 1000)
Range
0 to 65.53 V
Unit
V

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Aux battery voltage VENZA_AUX_BAT_VConfirmed

  • Request22 10 02
  • Service 22DID 1002
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0x2834 = 10292 → (10292 × 61 ÷ 50000) = 12.55624 V

Formula
(val × 61 ÷ 50000)
Range
0 to 79.95 V
Unit
V

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Aux. battery capacity after IG OFF VENZA_AUX_BAT_CAP_AFTER_IG_OFF

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 Ah
Unit
Ah

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Aux. battery capacity after IG ON VENZA_AUX_BAT_CAP_AFTER_IG_ON

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 Ah
Unit
Ah

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Auxiliary battery current VENZA_AUXILIARY_BAT

  • Request22 18 02
  • Service 22DID 1802
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2525 ÷ 13107 − 12500)
Range
-12500 to -12451 A
Unit
A

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Battery current VENZA_BAT_CURRENT_700

  • Request22 15 F7
  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 49 ÷ 12850 − 125)
Range
-125 to 124.9 A
Unit
A

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Battery heater temperature VENZA_BAT_HEATER_T

  • Request22 18 24
  • Service 22DID 1824
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Battery status of full charge VENZA_BAT_STAT_FULL_CHG

  • Request22 15 E5
  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 255 ÷ 2)
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Battery temperature VENZA_BAT_T_700

  • Request22 15 F8
  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Battery temperature VENZA_BAT_T_700_2

  • Request22 1F F8
  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Battery temperature 01 VENZA_BAT_T_01Confirmed

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0x52C5 = 21189 → (21189 × 19531 ÷ 5000000 − 50) = 32.768472 °C

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Battery temperature 02 VENZA_BAT_T_02Confirmed

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 16 to 31 of the reply, 16 bits.

0x535C = 21340 → (21340 × 19531 ÷ 5000000 − 50) = 33.358308 °C

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Battery temperature 03 VENZA_BAT_T_03Confirmed

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 32 to 47 of the reply, 16 bits.

0x5330 = 21296 → (21296 × 19531 ÷ 5000000 − 50) = 33.186435 °C

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Battery temperature 04 VENZA_BAT_T_04Confirmed

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 48 to 63 of the reply, 16 bits.

0x52C5 = 21189 → (21189 × 19531 ÷ 5000000 − 50) = 32.768472 °C

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Battery temperature 05 VENZA_BAT_T_05Confirmed

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 64 to 79 of the reply, 16 bits.

0x5338 = 21304 → (21304 × 19531 ÷ 5000000 − 50) = 33.217685 °C

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Battery temperature 06 VENZA_BAT_T_06Confirmed

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 80 to 95 of the reply, 16 bits.

0x5285 = 21125 → (21125 × 19531 ÷ 5000000 − 50) = 32.518475 °C

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Battery temperature 07 VENZA_BAT_T_07

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 08 VENZA_BAT_T_08

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 09 VENZA_BAT_T_09

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 128 to 143 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 10 VENZA_BAT_T_10

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 11 VENZA_BAT_T_11

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 160 to 175 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 12 VENZA_BAT_T_12

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 13 VENZA_BAT_T_13

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 14 VENZA_BAT_T_14

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 15 VENZA_BAT_T_15

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery temperature 16 VENZA_BAT_T_16

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Bits 240 to 255 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Supported for 2023.

Battery voltage VENZA_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 02
  • Service 22DID 1002
  • Module700 → 708
  • Every5 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0x2580 = 9600 → (9600 × 12.207 ÷ 10000) = 11.71872 V

Formula
(val × 12.207 ÷ 10000)
Range
0 to 79 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

Battery voltage VENZA_BAT_V

  • Request21 13
  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Charge contactor current VENZA_SCC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Charging integrated current of aux. battery VENZA_CHG_INTEGRATED

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Dark current of battery VENZA_DARK_CURRENT_BAT

  • Request22 15 E7
  • Service 22DID 15E7
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

DC-DC converter high side voltage VENZA_DC_DC_CONV_HIGH_SIDE_V

  • Request22 11 1E
  • Service 22DID 111E
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1220703 ÷ 10000000)
Range
0 to 7999 V
Unit
V

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

DC-DC converter low side voltage VENZA_DC_DC_CONV_LOW_SIDE_V

  • Request22 11 1D
  • Service 22DID 111D
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1953 ÷ 25000)
Range
0 to 19.92 V
Unit
V

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

DC-DC converter, target voltage before charging VENZA_DC_DC_CONV_TGT_V

  • Request22 11 1F
  • Service 22DID 111F
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1220703 ÷ 10000000)
Range
0 to 7999 V
Unit
V

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Discharging integrated current of aux. battery VENZA_DISCHARGING

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Distance since last battery cable disconnection VENZA_DIST_SINCE_BAT_DISCConfirmed

  • Request22 10 6C
  • Service 22DID 106C
  • Module700 → 708
  • Every30 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0xFFFF = 65535 → 65,535 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery charge voltage VENZA_HVBAT_CHRG_V

  • Request22 16 09
  • Service 22DID 1609
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

HV battery charge, maximum VENZA_HVBAT_SOC_MAXConfirmed

  • Request22 10 6C
  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 8 to 15 of the reply, 8 bits.

0x39 = 57 → (57 ÷ 2) = 28.5 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery charge, minimum VENZA_HVBAT_SOC_MINConfirmed

  • Request22 10 6C
  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 16 to 23 of the reply, 8 bits.

0x35 = 53 → (53 ÷ 2) = 26.5 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery current VENZA_HVBAT_CConfirmed

Pelican can show this parameter as the traction battery current.

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

0x02C0 = 704 → (704 ÷ 10) = 70.4 A

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery maximum temperature VENZA_HVBAT_MAX_T

  • Request22 18 29
  • Service 22DID 1829
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

HV battery minimum temperature VENZA_HVBAT_MIN_T

  • Request22 18 2A
  • Service 22DID 182A
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

HV battery voltage VENZA_HVBAT_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 16 to 31 of the reply, 16 bits.

0x39C0 = 14784 → (14784 × 156.25 ÷ 10000) = 231 V

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1023 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

Hybrid battery 1 fan VENZA_HYBRID_BAT_1_FAN

  • Request22 18 02
  • Service 22DID 1802
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Hybrid battery temperature 1 VENZA_HYBRID_BAT_T_1

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 458 ÷ 65535 − 58)
Range
-58 to 400 °F
Unit
°F

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Hybrid battery temperature 2 VENZA_HYBRID_BAT_T_2

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 58)
Range
-58 to 401 °F
Unit
°F

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Hybrid battery temperature 3 VENZA_HYBRID_BAT_T_3

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 458 ÷ 65535 − 58)
Range
-58 to 400 °F
Unit
°F

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Initial engine battery voltage lower limit VENZA_INITIAL_ENG_BAT_V_LO

  • Request22 15 F6
  • Service 22DID 15F6
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Main connector solenoid current VENZA_SMC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Main relay a, solenoid current VENZA_SLA_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Main relay r solenoid current VENZA_SLR_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Regenerative braking cooperation VENZA_REGEN_COOPERATION

  • Request21 58
  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Regenerative operation VENZA_FR_REGEN_OPERATION

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Regenerative request VENZA_FR_REGEN_REQUEST

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Relay control solenoid current VENZA_SRC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Service contactor solenoid current VENZA_SSC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2009 to 2015, 2022, 2024 to 2026. Not supported for 2021, 2023.

Sleep time of battery sensor VENZA_SLEEP_TIME_BATSENS

  • Request22 15 F0
  • Service 22DID 15F0
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

State of charge VENZA_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 7 of the reply, 8 bits.

0x35 = 53 → (53 × 100 ÷ 255) = 20.784314 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

State of charge, battery ECU VENZA_SOC_747Confirmed

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module747 → 74F
  • Every10 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 7 of the reply, 8 bits.

0x46 = 70 → (70 ÷ 2.55) = 27.45098 %

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Vh-voltage after boosting VENZA_VH_V_AFTER_BOOSTINGConfirmed

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 16 to 31 of the reply, 16 bits.

0x01DF = 479 → (479 ÷ 2) = 239.5 V

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Vl-voltage before boosting VENZA_VL_V_BEFORE_BOOSTINGConfirmed

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2009 to 2015, 2021 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0x01DE = 478 → (478 ÷ 2) = 239 V

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

Confirmed for 2023. In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026.

Voltage of battery sensor VENZA_V_BATSENS

  • Request22 15 EE
  • Service 22DID 15EE
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13333 ÷ 10922500)
Range
0 to 79.9979 V
Unit
V

In testing for 2009 to 2015, 2021 to 2022, 2024 to 2026. Not supported for 2023.

Battery › Cells

HV battery cell #01 voltage VENZA_HVBAT_C01_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 0 to 15 of the reply, 16 bits.

0xA46A = 42090 → (42090 × 5 ÷ 65535) = 3.211261 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #02 voltage VENZA_HVBAT_C02_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #03 voltage VENZA_HVBAT_C03_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 32 to 47 of the reply, 16 bits.

0xA4D9 = 42201 → (42201 × 5 ÷ 65535) = 3.21973 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #04 voltage VENZA_HVBAT_C04_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 48 to 63 of the reply, 16 bits.

0xA4D9 = 42201 → (42201 × 5 ÷ 65535) = 3.21973 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #05 voltage VENZA_HVBAT_C05_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #06 voltage VENZA_HVBAT_C06_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 80 to 95 of the reply, 16 bits.

0xA50A = 42250 → (42250 × 5 ÷ 65535) = 3.223468 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #07 voltage VENZA_HVBAT_C07_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 96 to 111 of the reply, 16 bits.

0xA4C9 = 42185 → (42185 × 5 ÷ 65535) = 3.218509 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #08 voltage VENZA_HVBAT_C08_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #09 voltage VENZA_HVBAT_C09_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 128 to 143 of the reply, 16 bits.

0xA4C9 = 42185 → (42185 × 5 ÷ 65535) = 3.218509 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #10 voltage VENZA_HVBAT_C10_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #11 voltage VENZA_HVBAT_C11_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 160 to 175 of the reply, 16 bits.

0xA4D9 = 42201 → (42201 × 5 ÷ 65535) = 3.21973 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #12 voltage VENZA_HVBAT_C12_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #13 voltage VENZA_HVBAT_C13_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 192 to 207 of the reply, 16 bits.

0xA4E9 = 42217 → (42217 × 5 ÷ 65535) = 3.220951 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #14 voltage VENZA_HVBAT_C14_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 208 to 223 of the reply, 16 bits.

0xA4D9 = 42201 → (42201 × 5 ÷ 65535) = 3.21973 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #15 voltage VENZA_HVBAT_C15_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #16 voltage VENZA_HVBAT_C16_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 240 to 255 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #17 voltage VENZA_HVBAT_C17_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 256 to 271 of the reply, 16 bits.

0xA4E9 = 42217 → (42217 × 5 ÷ 65535) = 3.220951 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #18 voltage VENZA_HVBAT_C18_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 272 to 287 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #19 voltage VENZA_HVBAT_C19_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 288 to 303 of the reply, 16 bits.

0xA45A = 42074 → (42074 × 5 ÷ 65535) = 3.21004 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #20 voltage VENZA_HVBAT_C20_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 304 to 319 of the reply, 16 bits.

0xA4C9 = 42185 → (42185 × 5 ÷ 65535) = 3.218509 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #21 voltage VENZA_HVBAT_C21_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 320 to 335 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #22 voltage VENZA_HVBAT_C22_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 336 to 351 of the reply, 16 bits.

0xA4D9 = 42201 → (42201 × 5 ÷ 65535) = 3.21973 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #23 voltage VENZA_HVBAT_C23_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 352 to 367 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #24 voltage VENZA_HVBAT_C24_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 368 to 383 of the reply, 16 bits.

0xA4C9 = 42185 → (42185 × 5 ÷ 65535) = 3.218509 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #25 voltage VENZA_HVBAT_C25_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 384 to 399 of the reply, 16 bits.

0xA4FA = 42234 → (42234 × 5 ÷ 65535) = 3.222248 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #26 voltage VENZA_HVBAT_C26_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 400 to 415 of the reply, 16 bits.

0xA4C9 = 42185 → (42185 × 5 ÷ 65535) = 3.218509 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #27 voltage VENZA_HVBAT_C27_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 416 to 431 of the reply, 16 bits.

0xA4FA = 42234 → (42234 × 5 ÷ 65535) = 3.222248 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #28 voltage VENZA_HVBAT_C28_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 432 to 447 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #29 voltage VENZA_HVBAT_C29_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 448 to 463 of the reply, 16 bits.

0xA54A = 42314 → (42314 × 5 ÷ 65535) = 3.228351 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #30 voltage VENZA_HVBAT_C30_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 464 to 479 of the reply, 16 bits.

0xA4E9 = 42217 → (42217 × 5 ÷ 65535) = 3.220951 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #31 voltage VENZA_HVBAT_C31_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 480 to 495 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #32 voltage VENZA_HVBAT_C32_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 496 to 511 of the reply, 16 bits.

0xA53A = 42298 → (42298 × 5 ÷ 65535) = 3.227131 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #33 voltage VENZA_HVBAT_C33_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 512 to 527 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #34 voltage VENZA_HVBAT_C34_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 528 to 543 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #35 voltage VENZA_HVBAT_C35_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 544 to 559 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #36 voltage VENZA_HVBAT_C36_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 560 to 575 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #37 voltage VENZA_HVBAT_C37_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 576 to 591 of the reply, 16 bits.

0xA5B9 = 42425 → (42425 × 5 ÷ 65535) = 3.23682 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #38 voltage VENZA_HVBAT_C38_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 592 to 607 of the reply, 16 bits.

0xA55A = 42330 → (42330 × 5 ÷ 65535) = 3.229572 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #39 voltage VENZA_HVBAT_C39_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 608 to 623 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #40 voltage VENZA_HVBAT_C40_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 624 to 639 of the reply, 16 bits.

0xA54A = 42314 → (42314 × 5 ÷ 65535) = 3.228351 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #41 voltage VENZA_HVBAT_C41_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 640 to 655 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #42 voltage VENZA_HVBAT_C42_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 656 to 671 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #43 voltage VENZA_HVBAT_C43_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 672 to 687 of the reply, 16 bits.

0xA54A = 42314 → (42314 × 5 ÷ 65535) = 3.228351 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #44 voltage VENZA_HVBAT_C44_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 688 to 703 of the reply, 16 bits.

0xA54A = 42314 → (42314 × 5 ÷ 65535) = 3.228351 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #45 voltage VENZA_HVBAT_C45_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 704 to 719 of the reply, 16 bits.

0xA55A = 42330 → (42330 × 5 ÷ 65535) = 3.229572 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #46 voltage VENZA_HVBAT_C46_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 720 to 735 of the reply, 16 bits.

0xA579 = 42361 → (42361 × 5 ÷ 65535) = 3.231937 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #47 voltage VENZA_HVBAT_C47_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 736 to 751 of the reply, 16 bits.

0xA519 = 42265 → (42265 × 5 ÷ 65535) = 3.224613 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #48 voltage VENZA_HVBAT_C48_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 752 to 767 of the reply, 16 bits.

0xA54A = 42314 → (42314 × 5 ÷ 65535) = 3.228351 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #49 voltage VENZA_HVBAT_C49_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 768 to 783 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #50 voltage VENZA_HVBAT_C50_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 784 to 799 of the reply, 16 bits.

0xA4FA = 42234 → (42234 × 5 ÷ 65535) = 3.222248 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #51 voltage VENZA_HVBAT_C51_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 800 to 815 of the reply, 16 bits.

0xA519 = 42265 → (42265 × 5 ÷ 65535) = 3.224613 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #52 voltage VENZA_HVBAT_C52_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 816 to 831 of the reply, 16 bits.

0xA54A = 42314 → (42314 × 5 ÷ 65535) = 3.228351 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #53 voltage VENZA_HVBAT_C53_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 832 to 847 of the reply, 16 bits.

0xA4FA = 42234 → (42234 × 5 ÷ 65535) = 3.222248 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #54 voltage VENZA_HVBAT_C54_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 848 to 863 of the reply, 16 bits.

0xA50A = 42250 → (42250 × 5 ÷ 65535) = 3.223468 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #55 voltage VENZA_HVBAT_C55_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 864 to 879 of the reply, 16 bits.

0xA55A = 42330 → (42330 × 5 ÷ 65535) = 3.229572 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #56 voltage VENZA_HVBAT_C56_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 880 to 895 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #57 voltage VENZA_HVBAT_C57_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 896 to 911 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #58 voltage VENZA_HVBAT_C58_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 912 to 927 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #59 voltage VENZA_HVBAT_C59_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 928 to 943 of the reply, 16 bits.

0xA50A = 42250 → (42250 × 5 ÷ 65535) = 3.223468 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #60 voltage VENZA_HVBAT_C60_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 944 to 959 of the reply, 16 bits.

0xA54A = 42314 → (42314 × 5 ÷ 65535) = 3.228351 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #61 voltage VENZA_HVBAT_C61_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 960 to 975 of the reply, 16 bits.

0xA519 = 42265 → (42265 × 5 ÷ 65535) = 3.224613 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #62 voltage VENZA_HVBAT_C62_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 976 to 991 of the reply, 16 bits.

0xA53A = 42298 → (42298 × 5 ÷ 65535) = 3.227131 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #63 voltage VENZA_HVBAT_C63_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 992 to 1,007 of the reply, 16 bits.

0xA55A = 42330 → (42330 × 5 ÷ 65535) = 3.229572 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #64 voltage VENZA_HVBAT_C64_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #65 voltage VENZA_HVBAT_C65_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 1,024 to 1,039 of the reply, 16 bits.

0xA519 = 42265 → (42265 × 5 ÷ 65535) = 3.224613 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #66 voltage VENZA_HVBAT_C66_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 1,040 to 1,055 of the reply, 16 bits.

0xA53A = 42298 → (42298 × 5 ÷ 65535) = 3.227131 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #67 voltage VENZA_HVBAT_C67_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #68 voltage VENZA_HVBAT_C68_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 1,072 to 1,087 of the reply, 16 bits.

0xA55A = 42330 → (42330 × 5 ÷ 65535) = 3.229572 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #69 voltage VENZA_HVBAT_C69_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 1,088 to 1,103 of the reply, 16 bits.

0xA55A = 42330 → (42330 × 5 ÷ 65535) = 3.229572 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #70 voltage VENZA_HVBAT_C70_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Example reply from a 2023 Toyota Venza.

Bits 1,104 to 1,119 of the reply, 16 bits.

0xA54A = 42314 → (42314 × 5 ÷ 65535) = 3.228351 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #71 voltage VENZA_HVBAT_C71_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #72 voltage VENZA_HVBAT_C72_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #73 voltage VENZA_HVBAT_C73_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #74 voltage VENZA_HVBAT_C74_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #75 voltage VENZA_HVBAT_C75_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #76 voltage VENZA_HVBAT_C76_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #77 voltage VENZA_HVBAT_C77_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #78 voltage VENZA_HVBAT_C78_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #79 voltage VENZA_HVBAT_C79_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #80 voltage VENZA_HVBAT_C80_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #81 voltage VENZA_HVBAT_C81_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #82 voltage VENZA_HVBAT_C82_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #83 voltage VENZA_HVBAT_C83_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #84 voltage VENZA_HVBAT_C84_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #85 voltage VENZA_HVBAT_C85_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #86 voltage VENZA_HVBAT_C86_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #87 voltage VENZA_HVBAT_C87_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #88 voltage VENZA_HVBAT_C88_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #89 voltage VENZA_HVBAT_C89_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #90 voltage VENZA_HVBAT_C90_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #91 voltage VENZA_HVBAT_C91_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #92 voltage VENZA_HVBAT_C92_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #93 voltage VENZA_HVBAT_C93_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #94 voltage VENZA_HVBAT_C94_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #95 voltage VENZA_HVBAT_C95_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

HV battery cell #96 voltage VENZA_HVBAT_C96_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 2009 to 2015, 2022, 2024 to 2026

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2009 to 2015, 2022, 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.