Toyota Sienna Hybrid

Climate parameters

The Toyota Sienna Hybrid has 17 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient temperature SIENNAH_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Toyota Sienna Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x1D = 29 → (29 − 40) = -11 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adjusted ambient temperature SIENNAH_ADJUSTED_AMBIENT_T

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Air inlet damper actual pulse SIENNAH_AIR_INLET_DAMPER_ACTUAL_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Air inlet damper target pulse SIENNAH_AIR_INLET_DAMPER_TARGET_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Air outlet servo actual pulse, driver SIENNAH_AIR_OUTLET_SERVO_ACTU_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Air outlet servo pulse, driver SIENNAH_AIR_OUTLET_SERVO_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Ambient air temperature SIENNAH_AAT_7C4

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Ambient temperature SIENNAH_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Toyota Sienna Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x1D = 29 → (29 − 40) = -11 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2022, 2024 to 2026.

Ambient temperature, climate SIENNAH_AAT_7C4_V2Confirmed

  • Request22 10 02
  • Service 22DID 1002
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Toyota Sienna Hybrid.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0808 = 2056 → (2056 ÷ 100) = 20.56 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2022, 2024 to 2026.

Blower level SIENNAH_BLOWERConfirmed

  • Request22 28 01
  • Service 22DID 2801
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Toyota Sienna Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x07 = 7 → 7

Formula
val
Range
0 to 7
Unit
Number

Confirmed for 2021, 2023. In testing for 2022, 2024 to 2026.

Blower motor speed level SIENNAH_BLOWER_MOTOR_SPEED_LEVEL

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Cabin temperature SIENNAH_CABIN_T

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Cabin temperature SIENNAH_CABIN_T_V2Confirmed

  • Request22 10 01
  • Service 22DID 1001
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Toyota Sienna Hybrid.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x08B6 = 2230 → (2230 ÷ 100) = 22.3 °C

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2022, 2024 to 2026.

Climate set point code SIENNAH_HVAC_SET_RAWConfirmed

  • Request22 10 36
  • Service 22DID 1036
  • Module7C4 → 7CC
  • Every10 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Toyota Sienna Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x2E = 46 → 46

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021, 2023. In testing for 2022, 2024 to 2026.

Evaporator fin thermistor SIENNAH_EVAP_FIN_THERMISTOR

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Evaporator target temperature SIENNAH_EVAP_TARGET_T

  • Request21 4C
  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67
Unit
Number

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Set temperature, driver side SIENNAH_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Solar sensor, driver side SIENNAH_SOLAR_DRIVER

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022, 2024 to 2026. Not supported for 2021, 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.