Toyota Prius v

Climate parameters

The Toyota Prius v has 33 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Adjusted ambient temperature TOYOTA_ADJUSTED_AMBIENT_TConfirmed

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x9B = 155 → (155 × 81.6 ÷ 255 − 30.8) = 18.8 °C

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor pressure TOYOTA_IA_AC_P

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

In testing for 2011 to 2017.

A/C compressor pressure sensor voltage TOYOTA_IA_AC_P_SENS_V

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

In testing for 2011 to 2017.

A/C compressor, state TOYOTA_IA_AC_STATE

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2017.

Adjusted ambient temperature TOYOTA_ADJUSTED_AMBIENT_TConfirmed

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x9B = 155 → (155 × 81.6 ÷ 255 − 30.8) = 18.8 °C

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Air conditioner feedback TOYOTA_AC_FB

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val × 10 ÷ 8192 − 40)
Range
-40 to 39.99
Unit
Number

In testing for 2011 to 2013, 2016 to 2017. Not supported for 2014 to 2015.

Air conditioning inverter gate TOYOTA_AC_GATE

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 67 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2017.

Air conditioning power consumption TOYOTA_AC_PWR

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 kW
Unit
kW

In testing for 2011 to 2017.

Air conditioning requested TOYOTA_AC_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2017.

Air inlet damper actual pulse TOYOTA_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed

  • Request21 44
  • Service 21PID 44
  • Module7C4
  • Every1 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 8 to 15 of the reply, 8 bits.

0x07 = 7 → 7

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Air inlet damper target pulse TOYOTA_AIR_INLET_DAMPER_TARGET_PULSEConfirmed

  • Request21 44
  • Service 21PID 44
  • Module7C4
  • Every1 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x07 = 7 → 7

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Air outlet servo actual pulse, driver TOYOTA_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed

  • Request21 43
  • Service 21PID 43
  • Module7C4
  • Every1 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 8 to 15 of the reply, 8 bits.

0x2F = 47 → 47

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Air outlet servo pulse, driver TOYOTA_AIR_OUTLET_SERVO_PULSE_DConfirmed

  • Request21 43
  • Service 21PID 43
  • Module7C4
  • Every1 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x2F = 47 → 47

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Ambient air temperature TOYOTA_AAT_7C4Confirmed

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x7A = 122 → (122 × 89.25 ÷ 255 − 23.3) = 19.4 °C

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Ambient temperature TOYOTA_AMBIENT_T

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2013, 2016 to 2017. Not supported for 2014 to 2015.

Ambient temperature for A/C TOYOTA_AC_AMB_T

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2013, 2016 to 2017. Not supported for 2014 to 2015.

Ambient temperature, alternate TOYOTA_IA_AAT_ALT

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2011 to 2017.

Ambient temperature, climate TOYOTA_AAT_7C4_V2

  • Request22 10 02
  • Service 22DID 1002
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2011 to 2017.

Blower level TOYOTA_BLOWER

  • Request22 28 01
  • Service 22DID 2801
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2011 to 2017.

Blower motor speed level TOYOTA_BLOWER_MOTOR_SPEED_LEVELConfirmed

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Cabin mode active while parked TOYOTA_MY_ROOM

  • Request22 16 92
  • Service 22DID 1692
  • Module745 → 74D
  • Every10 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2011 to 2017.

Cabin temperature TOYOTA_CABIN_TConfirmed

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x8E = 142 → (142 × 63.75 ÷ 255 − 6.5) = 29 °C

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Cabin temperature TOYOTA_CABIN_T_V2

  • Request22 10 01
  • Service 22DID 1001
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2011 to 2017.

Climate control engine run requested TOYOTA_HVAC_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2017.

Climate power, charging control TOYOTA_HVAC_P_745

  • Request22 10 6E
  • Service 22DID 106E
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 kW
Unit
kW

In testing for 2011 to 2017.

Climate set point code TOYOTA_HVAC_SET_RAW

  • Request22 10 36
  • Service 22DID 1036
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2017.

Communication with air conditioner TOYOTA_COMM_WITH_AIR_CONDITIONERConfirmed

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bit 5 of the reply.

0b1 = 1 → 1

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Communication with HV TOYOTA_COMMUNICATION_WITH_HVConfirmed

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bit 2 of the reply.

0b1 = 1 → 1

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Communication with valvematic TOYOTA_COMM_WITH_VALVEMATIC_COMMConfirmed

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bit 6 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Electric heater power count TOYOTA_HEATER_RAW

  • Request22 10 86
  • Service 22DID 1086
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2017.

Evaporator fin thermistor TOYOTA_EVAP_FIN_THERMISTORConfirmed

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x5A = 90 → (90 × 89.25 ÷ 255 − 29.7) = 1.8 °C

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Evaporator target temperature TOYOTA_EVAP_TARGET_TConfirmed

  • Request21 4C
  • Service 21PID 4C
  • Module7C4
  • Every1 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 15 of the reply, 16 bits.

0x80C8 = 32968 → (32968 ÷ 100 − 327.68) = 2

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67
Unit
Number

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Set temperature, driver side TOYOTA_T_DRIVERConfirmed

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x28 = 40 → 40 °C

Formula
val
Range
0 to 255 °C
Unit
°C

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.

Solar sensor, driver side TOYOTA_SOLAR_DRIVERConfirmed

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Example reply from a 2015 Toyota Prius v.

Bits 0 to 7 of the reply, 8 bits.

0x0E = 14 → 14

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014 to 2015. In testing for 2011 to 2013, 2016 to 2017.