Toyota GR Corolla

Climate parameters

The Toyota GR Corolla has 13 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient temperature GRCOROLLA_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2022 to 2023

Example reply from a 2026 Toyota GR Corolla.

Bits 0 to 7 of the reply, 8 bits.

0x3F = 63 → (63 − 40) = 23 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2026. In testing for 2022 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adjusted ambient temperature GRCOROLLA_ADJUSTED_AMBIENT_T

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Air inlet damper actual pulse GRCOROLLA_AIR_INLET_DAMPER_ACTUAL_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Air inlet damper target pulse GRCOROLLA_AIR_INLET_DAMPER_TARGET_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Air outlet servo actual pulse, driver GRCOROLLA_AIR_OUTLET_SERVO_ACTU_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Air outlet servo pulse, driver GRCOROLLA_AIR_OUTLET_SERVO_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Ambient air temperature GRCOROLLA_AAT_7C4

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Ambient temperature GRCOROLLA_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2022 to 2023

Example reply from a 2026 Toyota GR Corolla.

Bits 0 to 7 of the reply, 8 bits.

0x3F = 63 → (63 − 40) = 23 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2026. In testing for 2022 to 2023.

Blower motor speed level GRCOROLLA_BLOWER_MOTOR_SPEED_LEVEL

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Cabin temperature GRCOROLLA_CABIN_T

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Evaporator fin thermistor GRCOROLLA_EVAP_FIN_THERMISTOR

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Evaporator target temperature GRCOROLLA_EVAP_TARGET_T

  • Request21 4C
  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67
Unit
Number

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Set temperature, driver side GRCOROLLA_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Solar sensor, driver side GRCOROLLA_SOLAR_DRIVER

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2023. Not supported for 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.