Tata Harrier

Transmission parameters

The Tata Harrier has 5 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Gear TATA_GEAR

  • Request22 D9 28
  • Service 22DID D928
  • Module732
  • Every1 s
  • Testing

Bits 0 to 6 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Gear TATA_GEAR

  • Request22 D9 28
  • Service 22DID D928
  • Module732
  • Every1 s
  • Testing

Bits 0 to 6 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2019 to 2026.

Gear engaged TATA_GEAR_ENGAGED

  • Request22 1E 1F
  • Service 22DID 1E1F
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Gear, commanded TATA_GEAR_CMD

  • Request22 1E 12
  • Service 22DID 1E12
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Torque converter temperature TATA_TQ_CONV_T

  • Request22 1F 12
  • Service 22DID 1F12
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 40)
Range
-40 to 470 °C
Unit
°C

In testing for 2019 to 2026.

Transmission fluid temperature TATA_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 1E 69
  • Service 22DID 1E69
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.