Suzuki Baleno

DTC parameters

The Suzuki Baleno has 23 DTC parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

2nd air monitor_avail SUZUKI_2ND_AIR_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

2nd air monitor_avail SUZUKI_2ND_AIR_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

2nd air monitor_incmpl SUZUKI_2ND_AIR_MONITOR_INCMPL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

A/C monitor_avail SUZUKI_A_C_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

A/C monitor_incmpl SUZUKI_A_C_MONITOR_INCMPL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Catalyst monitor_avail SUZUKI_CATALYST_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Catalyst monitor_incmpl SUZUKI_CATALYST_MONITOR_INCMPL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Complete parts monitor_avail SUZUKI_COMPLETE_PARTS_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

EGR/VVT monitor_avail SUZUKI_EGR_VVT_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

EGR/VVT monitor_incmpl SUZUKI_EGR_VVT_MONITOR_INCMPL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

EVAP monitor_avail SUZUKI_EVAP_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

EVAP monitor_icmpl SUZUKI_EVAP_MONITOR_ICMPL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Fuel system monitor_avail SUZUKI_FUEL_SYSTEM_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Heated catalyst monitor_avail SUZUKI_HEATED_CATALYST_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Heated catalyst monitor_incmpl SUZUKI_HEATED_CATALYST_MONITOR_INCMPL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

MIL SUZUKI_MIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

MIL ON run distance SUZUKI_MILON_RUN_DISTANCE

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2015 to 2026.

Misfire monitor_avail SUZUKI_MISFIRE_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Number of emission DTC SUZUKI_NUMBER_OF_EMISSION_DTC

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2015 to 2026.

O2S heater monitor_avail SUZUKI_O2S_A_FS_HEATER_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

O2S heater monitor_incmpl SUZUKI_O2S_A_FS_HEATER_MONITOR_INCMPL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

O2S monitor_avail SUZUKI_O2S_A_FS_MONITOR_AVAIL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

O2S monitor_incmpl SUZUKI_O2S_A_FS_MONITOR_INCMPL

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Running time from MIL ON SUZUKI_RUNNING_TIME_FROM_MIL_ON

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2015 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.