Suzuki Baleno

Battery parameters

The Suzuki Baleno has 222 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery current SUZUKI_12V_C

  • Request22 15 F7
  • Service 22DID 15F7
  • Module7D2 → 7DA
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 38.147 ÷ 10000 − 125)
Range
-125 to 124 A
Unit
A

In testing for 2015 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery current SUZUKI_12V_C

  • Request22 15 F7
  • Service 22DID 15F7
  • Module7D2 → 7DA
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 38.147 ÷ 10000 − 125)
Range
-125 to 124 A
Unit
A

In testing for 2015 to 2026.

12V battery temperature SUZUKI_12V_T

  • Request22 15 F8
  • Service 22DID 15F8
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2015 to 2026.

12V battery voltage SUZUKI_12V_V_V2

Pelican can show this parameter as the starter battery voltage.

  • Request22 15 EE
  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.31448 + 0.0125)
Range
0 to 80.2 V
Unit
V

In testing for 2015 to 2026.

AC charging operation status SUZUKI_AC_OP

  • Request22 16 84
  • Service 22DID 1684
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0STOPStopped
1STARTUPStarting up
2RUNNINGRunning
3FINISHINGFinishing

In testing for 2015 to 2026.

AC current limit SUZUKI_AC_A_LIMIT

  • Request22 16 19
  • Service 22DID 1619
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 A
Unit
A

In testing for 2015 to 2026.

AC target power SUZUKI_AC_P_TGT

  • Request22 16 19
  • Service 22DID 1619
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 kW
Unit
kW

In testing for 2015 to 2026.

AC usable power SUZUKI_AC_P_USABLE

  • Request22 16 65
  • Service 22DID 1665
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55 kW
Unit
kW

In testing for 2015 to 2026.

Air fuel sensor voltage, bank 1 sensor 1 SUZUKI_AFS_VOLTAGE_B1S1

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 7.99 ÷ 65535)
Range
0 to 7.99 V
Unit
V

In testing for 2015 to 2026.

Auxiliary battery voltage SUZUKI_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 5 − 25.6)
Range
-25.6 to 25.4 V
Unit
V

In testing for 2015 to 2026.

Battery charging power SUZUKI_CHG_P

  • Request22 10 D4
  • Service 22DID 10D4
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 kW
Unit
kW

In testing for 2015 to 2026.

Battery voltage SUZUKI_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 02
  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12.207 ÷ 10000)
Range
0 to 79 V
Unit
V

In testing for 2015 to 2026.

Battery voltage SUZUKI_BAT_V

  • Request21 13
  • Service 21PID 13
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2015 to 2026.

Battery voltage SUZUKI_BATTERY_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Boost converter carrier frequency SUZUKI_CONV_CARRIER

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 71 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Boost converter gate SUZUKI_CONV_GATE

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 66 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Boost converter input voltage SUZUKI_VL

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 2015 to 2026.

Boost converter output voltage SUZUKI_VH

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 2015 to 2026.

Boost converter pressure ratio SUZUKI_BOOST_RATIO

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.392)
Range
0 to 99.96 %
Unit
%

In testing for 2015 to 2026.

Boost converter temperature SUZUKI_CONV_T

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Charge contactor current SUZUKI_SCC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2015 to 2026.

Charge stop request code SUZUKI_CHG_STOP_REQ

  • Request22 16 67
  • Service 22DID 1667
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Charger input power SUZUKI_CHG_IN_P

  • Request22 16 1D
  • Service 22DID 161D
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kW
Unit
kW

In testing for 2015 to 2026.

Charger operation status SUZUKI_CHGR_OP

  • Request22 16 19
  • Service 22DID 1619
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1READYReady
2STOPStopped
3ROB_STOPStopped by request

In testing for 2015 to 2026.

Charger output power SUZUKI_CHGR_OUT_P

  • Request22 16 1E
  • Service 22DID 161E
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kW
Unit
kW

In testing for 2015 to 2026.

Charger output power, target SUZUKI_CHGR_OUT_P_TGT

  • Request22 16 1E
  • Service 22DID 161E
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kW
Unit
kW

In testing for 2015 to 2026.

Charger supply voltage type SUZUKI_CHG_V_TYPE

  • Request22 16 1C
  • Service 22DID 161C
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1V100100V series
2V200200V series

In testing for 2015 to 2026.

Control module voltage SUZUKI_CONTROL_MODULE_V

Pelican can show this parameter as the starter battery voltage.

  • Request21 00
  • Service 21PID 00
  • Module7DF
  • Every1 s
  • Testing

Bits 392 to 399 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2015 to 2026.

Control system mode SUZUKI_CTRL_MODE

  • Request22 10 D1
  • Service 22DID 10D1
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1DRIVINGDriving
3CHARGINGCharging

In testing for 2015 to 2026.

DC charger maximum current SUZUKI_DC_STA_A_MAX

  • Request22 16 79
  • Service 22DID 1679
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2015 to 2026.

DC charger maximum power SUZUKI_DC_STA_P_MAX

  • Request22 16 6A
  • Service 22DID 166A
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 kW
Unit
kW

In testing for 2015 to 2026.

DC charger maximum voltage SUZUKI_DC_STA_V_MAX

  • Request22 16 81
  • Service 22DID 1681
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2015 to 2026.

DC charger present current SUZUKI_DC_STA_A

  • Request22 16 6C
  • Service 22DID 166C
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2015 to 2026.

DC charger present voltage SUZUKI_DC_STA_V

  • Request22 16 6B
  • Service 22DID 166B
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2015 to 2026.

DC high level communication state SUZUKI_HLC

  • Request22 16 66
  • Service 22DID 1666
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Distance since last battery cable disconnection SUZUKI_DIST_SINCE_BAT_DISC

  • Request22 10 6C
  • Service 22DID 106C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2015 to 2026.

Full charge capacity 1 SUZUKI_CAP_1

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2015 to 2026.

Full charge capacity 2 SUZUKI_CAP_2

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2015 to 2026.

Full charge capacity 3 SUZUKI_CAP_3

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2015 to 2026.

Full charge capacity 4 SUZUKI_CAP_4

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2015 to 2026.

Full charge capacity 5 SUZUKI_CAP_5

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2015 to 2026.

Full charge capacity 6 SUZUKI_CAP_6

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2015 to 2026.

Full charge capacity 7 SUZUKI_CAP_7

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2015 to 2026.

Full charge capacity 8 SUZUKI_CAP_8

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2015 to 2026.

HV battery block 1 internal resistance SUZUKI_HVBAT_BLOCK_1_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 1 voltage SUZUKI_HVBAT_BLOCK_1_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 2 internal resistance SUZUKI_HVBAT_BLOCK_2_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 2 voltage SUZUKI_HVBAT_BLOCK_2_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 3 internal resistance SUZUKI_HVBAT_BLOCK_3_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 3 voltage SUZUKI_HVBAT_BLOCK_3_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 4 internal resistance SUZUKI_HVBAT_BLOCK_4_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 4 voltage SUZUKI_HVBAT_BLOCK_4_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 5 internal resistance SUZUKI_HVBAT_BLOCK_5_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 5 voltage SUZUKI_HVBAT_BLOCK_5_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 6 internal resistance SUZUKI_HVBAT_BLOCK_6_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 6 voltage SUZUKI_HVBAT_BLOCK_6_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 7 internal resistance SUZUKI_HVBAT_BLOCK_7_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 7 voltage SUZUKI_HVBAT_BLOCK_7_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 8 internal resistance SUZUKI_HVBAT_BLOCK_8_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 8 voltage SUZUKI_HVBAT_BLOCK_8_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 9 internal resistance SUZUKI_HVBAT_BLOCK_9_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 9 voltage SUZUKI_HVBAT_BLOCK_9_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 10 internal resistance SUZUKI_HVBAT_BLOCK_10_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 10 voltage SUZUKI_HVBAT_BLOCK_10_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 11 internal resistance SUZUKI_HVBAT_BLOCK_11_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 11 voltage SUZUKI_HVBAT_BLOCK_11_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 12 internal resistance SUZUKI_HVBAT_BLOCK_12_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 12 voltage SUZUKI_HVBAT_BLOCK_12_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 13 internal resistance SUZUKI_HVBAT_BLOCK_13_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 13 voltage SUZUKI_HVBAT_BLOCK_13_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block 14 internal resistance SUZUKI_HVBAT_BLOCK_14_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2015 to 2026.

HV battery block 14 voltage SUZUKI_HVBAT_BLOCK_14_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block count SUZUKI_HVBAT_BLOCKS

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

HV battery block voltage, highest SUZUKI_HVBAT_BLOCK_V_MAX

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block voltage, lowest SUZUKI_HVBAT_BLOCK_V_MIN

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2015 to 2026.

HV battery block with the highest voltage SUZUKI_HVBAT_BLOCK_V_MAX_NO

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

HV battery block with the lowest voltage SUZUKI_HVBAT_BLOCK_V_MIN_NO

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

HV battery charge SUZUKI_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 2015 to 2026.

HV battery charge (displayed) SUZUKI_HVBAT_SOC_DISPLAY

Pelican can show this parameter as the state of charge.

  • Request22 17 39
  • Service 22DID 1739
  • Module745
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

HV battery charge (max) SUZUKI_HVBAT_SOC_MAX

  • Request22 10 6C
  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

HV battery charge (min) SUZUKI_HVBAT_SOC_MIN

  • Request22 10 6C
  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

HV battery charge power limit SUZUKI_HVBAT_CHG_LIM

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 kW
Unit
kW

In testing for 2015 to 2026.

HV battery charge spread SUZUKI_HVBAT_DELTA_SOC

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55 %
Unit
%

In testing for 2015 to 2026.

HV battery charge voltage SUZUKI_HVBAT_CHRG_V

  • Request22 16 09
  • Service 22DID 1609
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 V
Unit
V

In testing for 2015 to 2026.

HV battery charge, hybrid control SUZUKI_HV_SOC

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val × 0.392)
Range
0 to 99.96 %
Unit
%

In testing for 2015 to 2026.

HV battery current SUZUKI_HVBAT_C

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2015 to 2026.

HV battery current SUZUKI_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Request21 CE
  • Service 21PID CE
  • Module7E3
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 A
Unit
A

In testing for 2015 to 2026.

HV battery DC inhibit time SUZUKI_HVBAT_DC_INHIBIT_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2015 to 2026.

HV battery discharge power limit SUZUKI_HVBAT_DISCHG_LIM

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 kW
Unit
kW

In testing for 2015 to 2026.

HV battery discharge power limit SUZUKI_WOUT

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every250 ms
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 320)
Range
0 to 81600 W
Unit
W

In testing for 2015 to 2026.

HV battery fan motor voltage SUZUKI_HVBAT_FAN_V

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 5 − 25.6)
Range
-25.6 to 25.4 V
Unit
V

In testing for 2015 to 2026.

HV battery fan speed SUZUKI_HVBAT_FAN

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

HV battery high charge time SUZUKI_HVBAT_HIGH_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2015 to 2026.

HV battery hot temperature time SUZUKI_HVBAT_HOT_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2015 to 2026.

HV battery intake air temperature SUZUKI_HVBAT_INTAKE_T

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2015 to 2026.

HV battery low charge time SUZUKI_HVBAT_LOW_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3
  • Every30 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2015 to 2026.

HV battery maximum temperature SUZUKI_HVBAT_MAX_T

  • Request22 18 29
  • Service 22DID 1829
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

HV battery minimum temperature SUZUKI_HVBAT_MIN_T

  • Request22 18 2A
  • Service 22DID 182A
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

HV battery temperature 1 SUZUKI_HVBAT_T_1

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2015 to 2026.

HV battery temperature 2 SUZUKI_HVBAT_T_2

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2015 to 2026.

HV battery temperature 3 SUZUKI_HVBAT_T_3

  • Request21 CF
  • Service 21PID CF
  • Module7E3
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2015 to 2026.

HV battery voltage SUZUKI_HVBAT_V

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1023 V
Unit
V

In testing for 2015 to 2026.

Last charge outcome code SUZUKI_CHG_OUTCOME

  • Request22 16 88
  • Service 22DID 1688
  • Module745 → 74D
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Main battery charging requested SUZUKI_CHARGE_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Main connector solenoid current SUZUKI_SMC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2015 to 2026.

Main relay a, solenoid current SUZUKI_SLA_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2015 to 2026.

Main relay r solenoid current SUZUKI_SLR_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2015 to 2026.

Minimum permission power SUZUKI_CHG_P_PERMIT

  • Request22 16 A1
  • Service 22DID 16A1
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 kW
Unit
kW

In testing for 2015 to 2026.

Plug-in switch status SUZUKI_PISW

  • Request22 16 69
  • Service 22DID 1669
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Power resource current SUZUKI_IB

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 2 − 256)
Range
-256 to 254 A
Unit
A

In testing for 2015 to 2026.

Power resource voltage SUZUKI_VB

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every250 ms
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 2015 to 2026.

Regen cooperation SUZUKI_REGEN_COOPERATION

  • Request21 58
  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Regenerative operation SUZUKI_FR_REGEN_OPERATION

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2015 to 2026.

Regenerative request SUZUKI_FR_REGEN_REQUEST

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2015 to 2026.

Relay control solenoid current SUZUKI_SRC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2015 to 2026.

Service contactor solenoid current SUZUKI_SSC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2015 to 2026.

Short circuit wave highest value SUZUKI_SHORT_WAVE_V

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

State of charge SUZUKI_SOC

Pelican can show this parameter as the state of charge.

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module7D2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

State of charge, battery ECU SUZUKI_SOC_747

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module747 → 74F
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

State of charge, charging control SUZUKI_SOC_745

  • Request22 17 38
  • Service 22DID 1738
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

System main relay 1 SUZUKI_SMR1

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 63 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

System main relay 2 SUZUKI_SMR2

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

System main relay 3 SUZUKI_SMR3

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Target charging current SUZUKI_CHG_A_TGT

  • Request22 16 6D
  • Service 22DID 166D
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2015 to 2026.

Throttle position sensor voltage SUZUKI_THROTTLE_V

  • Request21 00
  • Service 21PID 00
  • Module7DF
  • Every1 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2015 to 2026.

Battery › Cells

HV battery cell #01 voltage SUZUKI_HVBAT_C01_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #02 voltage SUZUKI_HVBAT_C02_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #03 voltage SUZUKI_HVBAT_C03_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #04 voltage SUZUKI_HVBAT_C04_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #05 voltage SUZUKI_HVBAT_C05_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #06 voltage SUZUKI_HVBAT_C06_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #07 voltage SUZUKI_HVBAT_C07_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #08 voltage SUZUKI_HVBAT_C08_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #09 voltage SUZUKI_HVBAT_C09_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #10 voltage SUZUKI_HVBAT_C10_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #11 voltage SUZUKI_HVBAT_C11_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #12 voltage SUZUKI_HVBAT_C12_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #13 voltage SUZUKI_HVBAT_C13_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #14 voltage SUZUKI_HVBAT_C14_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #15 voltage SUZUKI_HVBAT_C15_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #16 voltage SUZUKI_HVBAT_C16_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #17 voltage SUZUKI_HVBAT_C17_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #18 voltage SUZUKI_HVBAT_C18_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #19 voltage SUZUKI_HVBAT_C19_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #20 voltage SUZUKI_HVBAT_C20_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #21 voltage SUZUKI_HVBAT_C21_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #22 voltage SUZUKI_HVBAT_C22_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #23 voltage SUZUKI_HVBAT_C23_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #24 voltage SUZUKI_HVBAT_C24_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #25 voltage SUZUKI_HVBAT_C25_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #26 voltage SUZUKI_HVBAT_C26_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #27 voltage SUZUKI_HVBAT_C27_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #28 voltage SUZUKI_HVBAT_C28_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #29 voltage SUZUKI_HVBAT_C29_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #30 voltage SUZUKI_HVBAT_C30_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #31 voltage SUZUKI_HVBAT_C31_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #32 voltage SUZUKI_HVBAT_C32_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #33 voltage SUZUKI_HVBAT_C33_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #34 voltage SUZUKI_HVBAT_C34_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #35 voltage SUZUKI_HVBAT_C35_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #36 voltage SUZUKI_HVBAT_C36_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #37 voltage SUZUKI_HVBAT_C37_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #38 voltage SUZUKI_HVBAT_C38_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #39 voltage SUZUKI_HVBAT_C39_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #40 voltage SUZUKI_HVBAT_C40_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #41 voltage SUZUKI_HVBAT_C41_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #42 voltage SUZUKI_HVBAT_C42_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #43 voltage SUZUKI_HVBAT_C43_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #44 voltage SUZUKI_HVBAT_C44_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #45 voltage SUZUKI_HVBAT_C45_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #46 voltage SUZUKI_HVBAT_C46_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #47 voltage SUZUKI_HVBAT_C47_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #48 voltage SUZUKI_HVBAT_C48_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #49 voltage SUZUKI_HVBAT_C49_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #50 voltage SUZUKI_HVBAT_C50_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #51 voltage SUZUKI_HVBAT_C51_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #52 voltage SUZUKI_HVBAT_C52_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #53 voltage SUZUKI_HVBAT_C53_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #54 voltage SUZUKI_HVBAT_C54_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #55 voltage SUZUKI_HVBAT_C55_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #56 voltage SUZUKI_HVBAT_C56_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #57 voltage SUZUKI_HVBAT_C57_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #58 voltage SUZUKI_HVBAT_C58_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #59 voltage SUZUKI_HVBAT_C59_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #60 voltage SUZUKI_HVBAT_C60_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #61 voltage SUZUKI_HVBAT_C61_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #62 voltage SUZUKI_HVBAT_C62_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #63 voltage SUZUKI_HVBAT_C63_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #64 voltage SUZUKI_HVBAT_C64_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #65 voltage SUZUKI_HVBAT_C65_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #66 voltage SUZUKI_HVBAT_C66_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #67 voltage SUZUKI_HVBAT_C67_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #68 voltage SUZUKI_HVBAT_C68_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #69 voltage SUZUKI_HVBAT_C69_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #70 voltage SUZUKI_HVBAT_C70_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #71 voltage SUZUKI_HVBAT_C71_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #72 voltage SUZUKI_HVBAT_C72_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #73 voltage SUZUKI_HVBAT_C73_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #74 voltage SUZUKI_HVBAT_C74_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #75 voltage SUZUKI_HVBAT_C75_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #76 voltage SUZUKI_HVBAT_C76_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #77 voltage SUZUKI_HVBAT_C77_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #78 voltage SUZUKI_HVBAT_C78_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #79 voltage SUZUKI_HVBAT_C79_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #80 voltage SUZUKI_HVBAT_C80_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #81 voltage SUZUKI_HVBAT_C81_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #82 voltage SUZUKI_HVBAT_C82_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #83 voltage SUZUKI_HVBAT_C83_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #84 voltage SUZUKI_HVBAT_C84_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #85 voltage SUZUKI_HVBAT_C85_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #86 voltage SUZUKI_HVBAT_C86_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #87 voltage SUZUKI_HVBAT_C87_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #88 voltage SUZUKI_HVBAT_C88_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #89 voltage SUZUKI_HVBAT_C89_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #90 voltage SUZUKI_HVBAT_C90_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #91 voltage SUZUKI_HVBAT_C91_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #92 voltage SUZUKI_HVBAT_C92_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #93 voltage SUZUKI_HVBAT_C93_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #94 voltage SUZUKI_HVBAT_C94_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #95 voltage SUZUKI_HVBAT_C95_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

HV battery cell #96 voltage SUZUKI_HVBAT_C96_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

Battery › Modules › 01

HV battery module 01 voltage SUZUKI_HVBAT_CMU01_VOLT

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

Battery › Modules › 02

HV battery module 02 voltage SUZUKI_HVBAT_CMU02_VOLT

  • Request22 18 2E
  • Service 22DID 182E
  • Module747
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 2015 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.