Engine parameters
The Subaru WRX STI has 53 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Ambient temperature for control SUBARU_AMBIENT_T_CTRL
- Request
22 12 D1 - Service 22
DID 12D1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 1994 to 2021.
Ambient temperature for sensor signal SUBARU_AMBIENT_T_SENS_SIG
- Request
22 12 CE - Service 22
DID 12CE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 1994 to 2021.
Continuously variable transmission temperature SUBARU_CVT_T
- Request
22 10 D2 - Service 22
DID 10D2 - Module
7A3 → 7AB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1994 to 2021.
Coolant temperature SUBARU_ECT
- Request
22 00 05 - Service 22
DID 0005 - Module
7A2 → 7AA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1994 to 2021.
Coolant temperature SUBARU_ECT_7E0
- Request
22 00 05 - Service 22
DID 0005 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1994 to 2021.
Cumulative ash ratio SUBARU_CUM_ASH_RAT
- Request
22 11 49 - Service 22
DID 1149 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1994 to 2021.
Cumulative ash ratio SUBARU_CUM_ASH_RAT_7E0
- Request
22 11 49 - Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1994 to 2021.
Diesel particulate filter regeneration attempts SUBARU_DPF_REGEN_CNT
- Request
22 11 A1 - Service 22
DID 11A1 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1994 to 2021.
Drive motor inverter temperature a SUBARU_DRIVEMOTOR_INVERTER_T_A
- Request
22 10 66 - Service 22
DID 1066 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1994 to 2021.
Drive motor inverter temperature b SUBARU_DRIVEMOTOR_INVERTER_T_B
- Request
22 10 67 - Service 22
DID 1067 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1994 to 2021.
Drive motor inverter temperature c SUBARU_DRIVEMOTOR_INVERTER_T_C
- Request
22 10 68 - Service 22
DID 1068 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1994 to 2021.
Drive motor temperature a SUBARU_DRIVEMOTOR_T_A
- Request
22 10 6D - Service 22
DID 106D - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 55)- Range
- -55 to 200 °C
- Unit
- °C
In testing for 1994 to 2021.
Drive motor temperature b SUBARU_DRIVEMOTOR_T_B
- Request
22 10 6E - Service 22
DID 106E - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 55)- Range
- -55 to 200 °C
- Unit
- °C
In testing for 1994 to 2021.
Electric load feedback value SUBARU_ELEC_LOAD_FEEDBACK
- Request
22 12 8D - Service 22
DID 128D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55 g/s
- Unit
- g/s
In testing for 1994 to 2021.
Electric waste gate valve position sensor learning value at fully-closed position SUBARU_EWG_VALVE_POSITION_SENSOR_LEARNING_CLOSED
- Request
22 10 D2 - Service 22
DID 10D2 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 39.8 ÷ 255 − 10)- Range
- -10 to 29 mm
- Unit
- mm
In testing for 1994 to 2021.
Engine oil temperature SUBARU_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 215 °C
- Unit
- °C
In testing for 1994 to 2021.
Engine oil temperature SUBARU_EOT_7E0
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1994 to 2021.
Engine oil temperature SUBARU_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 10 E7 - Service 22
DID 10E7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1994 to 2021.
Estimated catalyst temperature SUBARU_ESTIMATED_CATALYST_T
- Request
22 11 4B - Service 22
DID 114B - Module
7A2 → 7AA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 − 40)- Range
- -40 to 1235 °C
- Unit
- °C
In testing for 1994 to 2021.
Estimated DPF temperature SUBARU_ESTIMATED_DPF_T
- Request
22 11 4C - Service 22
DID 114C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 − 40)- Range
- -40 to 1235 °C
- Unit
- °C
In testing for 1994 to 2021.
Exhaust gas recirculation target valve opening angle SUBARU_EGR_TARGET_VALVE_OPENING_ANGLE
- Request
22 11 1B - Service 22
DID 111B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 1994 to 2021.
Exhaust gas temperature at DPF inlet SUBARU_EGT_DPF_INLET
- Request
22 00 3E - Service 22
DID 003E - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 1994 to 2021.
Exhaust gas temperature, catalyst inlet SUBARU_EGT_AT_CATALYST_INLET
- Request
22 00 3C - Service 22
DID 003C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 1994 to 2021.
Exhaust VVT cleaning self-recovery counter SUBARU_EXH_VVT_CLEANING
- Request
22 11 BF - Service 22
DID 11BF - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1994 to 2021.
Exhaust VVT retard angle left SUBARU_EXH_VVT_RETARD_ANG_LEFT
- Request
22 10 ED - Service 22
DID 10ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 1994 to 2021.
Exhaust VVT retard angle right SUBARU_EXH_VVT_RETARD_ANG
- Request
22 10 EC - Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 1994 to 2021.
Exhaust VVT retard, target angle left SUBARU_EXH_VVT_RETARD_TGT_ANG
- Request
22 12 92 - Service 22
DID 1292 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 1994 to 2021.
Exhaust VVT retard, target angle right SUBARU_EXH_VVT_RETARD_TGT
- Request
22 12 91 - Service 22
DID 1291 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 1994 to 2021.
Fuel temperature SUBARU_FUEL_T
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1994 to 2021.
Idle A/C load correction SUBARU_IDLE_AC_LOAD_CORR
- Request
22 12 8C - Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55 g/s
- Unit
- g/s
In testing for 1994 to 2021.
Idle dirty throttle correction SUBARU_IDLE_DIRTY_THROTTLE
- Request
22 12 8E - Service 22
DID 128E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 300)- Range
- -300 to 355 g/s
- Unit
- g/s
In testing for 1994 to 2021.
Idle mass air flow SUBARU_IDLE_MAF
- Request
22 12 89 - Service 22
DID 1289 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 1994 to 2021.
Idle mass air flow feedback correction SUBARU_IDLE_MAF_FEEDBACK
- Request
22 12 8A - Service 22
DID 128A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 300)- Range
- -300 to 355 g/s
- Unit
- g/s
In testing for 1994 to 2021.
Idle speed control learning value SUBARU_IDLE_SPD_CTRL
- Request
22 12 8B - Service 22
DID 128B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 300)- Range
- -300 to 355 g/s
- Unit
- g/s
In testing for 1994 to 2021.
Inlet air temperature SUBARU_INLET_AIR_T
- Request
22 30 7A - Service 22
DID 307A - Module
7A2 → 7AA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1.8 − 40)- Range
- -30 to 300 °F
- Unit
- °F
In testing for 1994 to 2021.
Inlet air temperature, after air filter SUBARU_INLET_AIR_T_AFTER_AIR_FILTER
- Request
22 11 1F - Service 22
DID 111F - Module
7A2 → 7AA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1994 to 2021.
Intake VVT advance, target angle left SUBARU_INT_VVT_ADVANCE_TGT_ANG
- Request
22 12 90 - Service 22
DID 1290 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 1994 to 2021.
Intake VVT advance, target angle right SUBARU_INT_VVT_ADVANCE_TGT
- Request
22 12 8F - Service 22
DID 128F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 1994 to 2021.
Intake VVT cleaning self-recovery counter SUBARU_INT_VVT_CLEANING
- Request
22 11 BE - Service 22
DID 11BE - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1994 to 2021.
Inverter temperature estimated SUBARU_INVERTER_T_ESTIMATED
- Request
22 10 65 - Service 22
DID 1065 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1994 to 2021.
Main throttle sensor SUBARU_MAIN_THROTTLE_SENS
- Request
22 12 77 - Service 22
DID 1277 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 1994 to 2021.
Mass air flow, average SUBARU_MAF_AVG
- Request
22 12 ED - Service 22
DID 12ED - Module
7A2 → 7AA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 1994 to 2021.
Primary boost control SUBARU_PRIMARY_BOOST_CTRL
- Request
22 10 AC - Service 22
DID 10AC - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1994 to 2021.
Primary boost control SUBARU_PRIMARY_BOOST_CTRL_7E0
- Request
22 10 AC - Service 22
DID 10AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1994 to 2021.
Purge density learn value SUBARU_PURGE_DENSITY_LEARN
- Request
22 12 95 - Service 22
DID 1295 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 332 ÷ 425 − 100)- Range
- -100 to 99.1999 %
- Unit
- %
In testing for 1994 to 2021.
Sub throttle sensor SUBARU_SUB_THROTTLE_SENS
- Request
22 12 76 - Service 22
DID 1276 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 1994 to 2021.
Transmission fluid temperature SUBARU_ATF_T
- Request
22 10 6B - Service 22
DID 106B - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1994 to 2021.
Transmission fluid temperature SUBARU_TCM_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 10 D2 - Service 22
DID 10D2 - Module
7A3 → 7AB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1994 to 2021.
Transmission lock-up SUBARU_TRANS_LOCK_UP
- Request
22 12 99 - Service 22
DID 1299 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 1994 to 2021.
Trip counter SUBARU_TRIP_CNT
- Request
22 10 1E - Service 22
DID 101E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1994 to 2021.
Tumble generator valve position sensor left SUBARU_TUMBLE_GEN_VLV_POS_SENS
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 1994 to 2021.
Tumble generator valve position sensor right SUBARU_TUMBLE_GEN_VLV_POS
- Request
22 10 AF - Service 22
DID 10AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 1994 to 2021.
Variable valve timing oil temperature SUBARU_VVTOT
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1994 to 2021.