Subaru WRX STI

Engine parameters

The Subaru WRX STI has 53 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient temperature for control SUBARU_AMBIENT_T_CTRL

  • Request22 12 D1
  • Service 22DID 12D1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 1994 to 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Ambient temperature for control SUBARU_AMBIENT_T_CTRL

  • Request22 12 D1
  • Service 22DID 12D1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 1994 to 2021.

Ambient temperature for sensor signal SUBARU_AMBIENT_T_SENS_SIG

  • Request22 12 CE
  • Service 22DID 12CE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 1994 to 2021.

Continuously variable transmission temperature SUBARU_CVT_T

  • Request22 10 D2
  • Service 22DID 10D2
  • Module7A3 → 7AB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1994 to 2021.

Coolant temperature SUBARU_ECT

  • Request22 00 05
  • Service 22DID 0005
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1994 to 2021.

Coolant temperature SUBARU_ECT_7E0

  • Request22 00 05
  • Service 22DID 0005
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1994 to 2021.

Cumulative ash ratio SUBARU_CUM_ASH_RAT

  • Request22 11 49
  • Service 22DID 1149
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1994 to 2021.

Cumulative ash ratio SUBARU_CUM_ASH_RAT_7E0

  • Request22 11 49
  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1994 to 2021.

Diesel particulate filter regeneration attempts SUBARU_DPF_REGEN_CNT

  • Request22 11 A1
  • Service 22DID 11A1
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1994 to 2021.

Drive motor inverter temperature a SUBARU_DRIVEMOTOR_INVERTER_T_A

  • Request22 10 66
  • Service 22DID 1066
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1994 to 2021.

Drive motor inverter temperature b SUBARU_DRIVEMOTOR_INVERTER_T_B

  • Request22 10 67
  • Service 22DID 1067
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1994 to 2021.

Drive motor inverter temperature c SUBARU_DRIVEMOTOR_INVERTER_T_C

  • Request22 10 68
  • Service 22DID 1068
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1994 to 2021.

Drive motor temperature a SUBARU_DRIVEMOTOR_T_A

  • Request22 10 6D
  • Service 22DID 106D
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 55)
Range
-55 to 200 °C
Unit
°C

In testing for 1994 to 2021.

Drive motor temperature b SUBARU_DRIVEMOTOR_T_B

  • Request22 10 6E
  • Service 22DID 106E
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 55)
Range
-55 to 200 °C
Unit
°C

In testing for 1994 to 2021.

Electric load feedback value SUBARU_ELEC_LOAD_FEEDBACK

  • Request22 12 8D
  • Service 22DID 128D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55 g/s
Unit
g/s

In testing for 1994 to 2021.

Electric waste gate valve position sensor learning value at fully-closed position SUBARU_EWG_VALVE_POSITION_SENSOR_LEARNING_CLOSED

  • Request22 10 D2
  • Service 22DID 10D2
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 39.8 ÷ 255 − 10)
Range
-10 to 29 mm
Unit
mm

In testing for 1994 to 2021.

Engine oil temperature SUBARU_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val − 40)
Range
0 to 215 °C
Unit
°C

In testing for 1994 to 2021.

Engine oil temperature SUBARU_EOT_7E0

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1994 to 2021.

Engine oil temperature SUBARU_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 E7
  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1994 to 2021.

Estimated catalyst temperature SUBARU_ESTIMATED_CATALYST_T

  • Request22 11 4B
  • Service 22DID 114B
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 − 40)
Range
-40 to 1235 °C
Unit
°C

In testing for 1994 to 2021.

Estimated DPF temperature SUBARU_ESTIMATED_DPF_T

  • Request22 11 4C
  • Service 22DID 114C
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 − 40)
Range
-40 to 1235 °C
Unit
°C

In testing for 1994 to 2021.

Exhaust gas recirculation target valve opening angle SUBARU_EGR_TARGET_VALVE_OPENING_ANGLE

  • Request22 11 1B
  • Service 22DID 111B
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 1994 to 2021.

Exhaust gas temperature at DPF inlet SUBARU_EGT_DPF_INLET

  • Request22 00 3E
  • Service 22DID 003E
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 1994 to 2021.

Exhaust gas temperature, catalyst inlet SUBARU_EGT_AT_CATALYST_INLET

  • Request22 00 3C
  • Service 22DID 003C
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 1994 to 2021.

Exhaust VVT cleaning self-recovery counter SUBARU_EXH_VVT_CLEANING

  • Request22 11 BF
  • Service 22DID 11BF
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1994 to 2021.

Exhaust VVT retard angle left SUBARU_EXH_VVT_RETARD_ANG_LEFT

  • Request22 10 ED
  • Service 22DID 10ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 1994 to 2021.

Exhaust VVT retard angle right SUBARU_EXH_VVT_RETARD_ANG

  • Request22 10 EC
  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 1994 to 2021.

Exhaust VVT retard, target angle left SUBARU_EXH_VVT_RETARD_TGT_ANG

  • Request22 12 92
  • Service 22DID 1292
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 1994 to 2021.

Exhaust VVT retard, target angle right SUBARU_EXH_VVT_RETARD_TGT

  • Request22 12 91
  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 1994 to 2021.

Fuel temperature SUBARU_FUEL_T

  • Request22 10 A7
  • Service 22DID 10A7
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1994 to 2021.

Idle A/C load correction SUBARU_IDLE_AC_LOAD_CORR

  • Request22 12 8C
  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55 g/s
Unit
g/s

In testing for 1994 to 2021.

Idle dirty throttle correction SUBARU_IDLE_DIRTY_THROTTLE

  • Request22 12 8E
  • Service 22DID 128E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 300)
Range
-300 to 355 g/s
Unit
g/s

In testing for 1994 to 2021.

Idle mass air flow SUBARU_IDLE_MAF

  • Request22 12 89
  • Service 22DID 1289
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 g/s
Unit
g/s

In testing for 1994 to 2021.

Idle mass air flow feedback correction SUBARU_IDLE_MAF_FEEDBACK

  • Request22 12 8A
  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 300)
Range
-300 to 355 g/s
Unit
g/s

In testing for 1994 to 2021.

Idle speed control learning value SUBARU_IDLE_SPD_CTRL

  • Request22 12 8B
  • Service 22DID 128B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 300)
Range
-300 to 355 g/s
Unit
g/s

In testing for 1994 to 2021.

Inlet air temperature SUBARU_INLET_AIR_T

  • Request22 30 7A
  • Service 22DID 307A
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1.8 − 40)
Range
-30 to 300 °F
Unit
°F

In testing for 1994 to 2021.

Inlet air temperature, after air filter SUBARU_INLET_AIR_T_AFTER_AIR_FILTER

  • Request22 11 1F
  • Service 22DID 111F
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1994 to 2021.

Intake VVT advance, target angle left SUBARU_INT_VVT_ADVANCE_TGT_ANG

  • Request22 12 90
  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 1994 to 2021.

Intake VVT advance, target angle right SUBARU_INT_VVT_ADVANCE_TGT

  • Request22 12 8F
  • Service 22DID 128F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 1994 to 2021.

Intake VVT cleaning self-recovery counter SUBARU_INT_VVT_CLEANING

  • Request22 11 BE
  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1994 to 2021.

Inverter temperature estimated SUBARU_INVERTER_T_ESTIMATED

  • Request22 10 65
  • Service 22DID 1065
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1994 to 2021.

Main throttle sensor SUBARU_MAIN_THROTTLE_SENS

  • Request22 12 77
  • Service 22DID 1277
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 1994 to 2021.

Mass air flow, average SUBARU_MAF_AVG

  • Request22 12 ED
  • Service 22DID 12ED
  • Module7A2 → 7AA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

In testing for 1994 to 2021.

Primary boost control SUBARU_PRIMARY_BOOST_CTRL

  • Request22 10 AC
  • Service 22DID 10AC
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1994 to 2021.

Primary boost control SUBARU_PRIMARY_BOOST_CTRL_7E0

  • Request22 10 AC
  • Service 22DID 10AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1994 to 2021.

Purge density learn value SUBARU_PURGE_DENSITY_LEARN

  • Request22 12 95
  • Service 22DID 1295
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 332 ÷ 425 − 100)
Range
-100 to 99.1999 %
Unit
%

In testing for 1994 to 2021.

Sub throttle sensor SUBARU_SUB_THROTTLE_SENS

  • Request22 12 76
  • Service 22DID 1276
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 1994 to 2021.

Transmission fluid temperature SUBARU_ATF_T

  • Request22 10 6B
  • Service 22DID 106B
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1994 to 2021.

Transmission fluid temperature SUBARU_TCM_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 10 D2
  • Service 22DID 10D2
  • Module7A3 → 7AB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1994 to 2021.

Transmission lock-up SUBARU_TRANS_LOCK_UP

  • Request22 12 99
  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1994 to 2021.

Trip counter SUBARU_TRIP_CNT

  • Request22 10 1E
  • Service 22DID 101E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1994 to 2021.

Tumble generator valve position sensor left SUBARU_TUMBLE_GEN_VLV_POS_SENS

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 1994 to 2021.

Tumble generator valve position sensor right SUBARU_TUMBLE_GEN_VLV_POS

  • Request22 10 AF
  • Service 22DID 10AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 1994 to 2021.

Variable valve timing oil temperature SUBARU_VVTOT

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1994 to 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.