Subaru BRZ

Battery parameters

The Subaru BRZ has 9 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery terminal voltage BRZ_BAT_TERMINAL_VOLTAGEConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 13 21
  • Service 22DID 1321
  • Module7A2 → 7AA
  • Every5 s
  • Testing for 2012 to 2020, 2025

Example reply from a 2026 Subaru BRZ.

Bits 0 to 15 of the reply, 16 bits.

0x2F82 = 12162 → (12162 ÷ 1000) = 12.162 V

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

Confirmed for 2023 to 2024, 2026. In testing for 2012 to 2014, 2016 to 2018, 2020, 2025. Supported for 2022. Not supported for 2015, 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery current BRZ_12V_C

  • Request22 11 35
  • Service 22DID 1135
  • Module7A2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 mA
Unit
mA

In testing for 2012, 2014, 2016 to 2018. Not supported for 2013, 2015, 2019 to 2020, 2022 to 2026.

12V battery temperature BRZ_12V_T

  • Request22 11 36
  • Service 22DID 1136
  • Module7A2
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012, 2014, 2016 to 2018. Not supported for 2013, 2015, 2019 to 2020, 2022 to 2026.

Battery charge/discharge current BRZ_BAT_CHARGE_DISCHARGE_CURRENTConfirmed

  • Request22 13 22
  • Service 22DID 1322
  • Module7A2 → 7AA
  • Every1 s
  • Testing for 2012 to 2020, 2022, 2025

Example reply from a 2026 Subaru BRZ.

Bits 0 to 31 of the reply, 32 bits.

0x001E2BDC = 1977308 → (1977308 × 10 ÷ 10000 − 2000) = -22.692 A

Formula
(val × 10 ÷ 10000 − 2000)
Range
-2000 to 4292967 A
Unit
A

Confirmed for 2023 to 2024, 2026. In testing for 2012 to 2014, 2016 to 2018, 2020, 2022, 2025. Not supported for 2015, 2019.

Battery terminal voltage BRZ_BAT_TERMINAL_VOLTAGEConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 13 21
  • Service 22DID 1321
  • Module7A2 → 7AA
  • Every5 s
  • Testing for 2012 to 2020, 2025

Example reply from a 2026 Subaru BRZ.

Bits 0 to 15 of the reply, 16 bits.

0x2F82 = 12162 → (12162 ÷ 1000) = 12.162 V

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

Confirmed for 2023 to 2024, 2026. In testing for 2012 to 2014, 2016 to 2018, 2020, 2025. Supported for 2022. Not supported for 2015, 2019.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2013, 2019 to 2020, 2022 to 2024. Supported for 2014 to 2015, 2025 to 2026.

Estimated battery temperature BRZ_ESTIMATED_BAT_TConfirmed

  • Request22 13 23
  • Service 22DID 1323
  • Module7A2 → 7AA
  • Every5 s
  • Testing for 2012 to 2020, 2025

Example reply from a 2026 Subaru BRZ.

Bits 0 to 15 of the reply, 16 bits.

0x0081 = 129 → (129 ÷ 2 − 40) = 24.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 32727.5 °C
Unit
°C

Confirmed for 2023 to 2024, 2026. In testing for 2012 to 2014, 2016 to 2018, 2020, 2025. Supported for 2022. Not supported for 2015, 2019.

Mass airflow sensor voltage BRZ_MAF_VOLTAGE

  • Request22 10 A1
  • Service 22DID 10A1
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 2012 to 2014, 2016 to 2018, 2020, 2022, 2025. Not supported for 2015, 2019, 2023 to 2024, 2026.

Remaining battery capacity BRZ_REMAINING_BAT_CAPACITYConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 13 24
  • Service 22DID 1324
  • Module7A2 → 7AA
  • Every1 s
  • Testing for 2012 to 2020, 2022, 2025

Example reply from a 2026 Subaru BRZ.

Bits 0 to 15 of the reply, 16 bits.

0x03D0 = 976 → (976 ÷ 10) = 97.6 %

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2024, 2026. In testing for 2012 to 2014, 2016 to 2018, 2020, 2022, 2025. Not supported for 2015, 2019.

Throttle motor voltage BRZ_THROTTLE_MOTOR_V

  • Request22 12 75
  • Service 22DID 1275
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 ÷ 25)
Range
0 to 20.4 V
Unit
V

In testing for 2012 to 2018, 2020, 2022, 2024 to 2026. Not supported for 2019, 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.