Scion iQ

Engine parameters

The Scion iQ has 242 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/F heater duty bank 1 sensor 1 IQ_F_HEATER_DUTY_B1S1

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2012 to 2015.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/F heater duty bank 1 sensor 1 IQ_F_HEATER_DUTY_B1S1

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learn value high, bank 1 IQ_AF_LEARN_HIGH_PORT_B1

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learn value idle, bank 1 IQ_AF_LEARN_IDLE_PORT_B1

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learn value low, bank 1 IQ_AF_LEARN_LOW_PORT_B1

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learn value mid.1, bank 1 IQ_AF_LEARN_MID1_PORT_B1

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learn value mid.2, bank 1 IQ_AF_LEARN_MID2_PORT_B1

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learned high, bank 1 IQ_A_F_RATIO_LEARNED_HIGH_BANK_1

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learned idle, bank 1 IQ_A_F_RATIO_LEARNED_IDLE_BANK_1

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learned low, bank 1 IQ_A_F_RATIO_LEARNED_LOW_BANK_1

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learned mid 1, bank 1 IQ_A_F_RATIO_LEARNED_MID_1_BANK_1

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F ratio learned mid 2, bank 1 IQ_A_F_RATIO_LEARNED_MID_2_BANK_1

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

In testing for 2012 to 2015.

A/F test results 1, incomplete IQ_F_TEST_RESULTS_1

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Accessory relay on IQ_ACC_RELAY_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Accumulator open IQ_ACCUMULATOR_OPEN

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2015.

Acoustic control induction system vacuum switching valve on IQ_ACIS_VSV_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Actual engine torque IQ_ACT_ENG_TQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val − 32768)
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2012 to 2015.

Actuator power supply on IQ_ACTUATOR_POWER_SUP_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Air conditioning compressor IQ_AC_COMP

  • Request21 E6
  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Air mix servo target pulse, driver IQ_AIR_MIX_SERVO_TARG_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Air mix servo, actual pulse, d IQ_AIR_MIX_SERVO_ACT_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Air-fuel equivalence ratio, bank 1 sensor 1 IQ_AF_LAMBDA_B1S1

Pelican can show this parameter as the O2 lambda.

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 1.99 ÷ 65535)
Range
0 to 1.99
Unit
Number

In testing for 2012 to 2015.

Air-fuel sensor current, bank 1 sensor 1 IQ_AFS_I_B1S1

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.99 mA
Unit
mA

In testing for 2012 to 2015.

Air-fuel sensor voltage, bank 1 sensor 1 IQ_AFS_V_B1S1

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 7.99 ÷ 65535)
Range
0 to 7.99 V
Unit
V

In testing for 2012 to 2015.

Alt voltage - active test IQ_ALT_VOL_ACTIVE_TEST

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2012 to 2015.

Alt voltage - non active test IQ_ALT_VOL_NON_ACTIVE

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2012 to 2015.

Alternator output duty IQ_ALTERNATOR_OUTPUT

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2012 to 2015.

Alternator output duty cycle IQ_ALT_DUTY_CYCLE

  • Request22 15 FA
  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 164)
Range
0 to 399 %
Unit
%

In testing for 2012 to 2015.

Atmospheric pressure IQ_ATMOSPHERE_PRESSURE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2012 to 2015.

Automatic transmission fluid thermal degradation estimate IQ_ATF_THERMAL_DEGRAD_EST

  • Request22 16 2B
  • Service 22DID 162B
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2015.

Calculated load IQ_CALCULATED_LOAD_7E0

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2015.

Catalyst temperature bank 2 sensor 1 IQ_CAT_T_BANK_2_SENS_1

  • Request22 1F 3D
  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2012 to 2015.

Catalyst temperature bank 2 sensor 2 IQ_CAT_T_BANK_2_SENS_2

  • Request22 1F 3F
  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2012 to 2015.

Catalyst temperature, bank 1 sensor 1 IQ_CAT_T_B1S1

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2015.

Catalyst temperature, bank 1 sensor 2 IQ_CAT_T_B1S2

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2015.

Catalyst temperature, bank 1 sensor 2, variant 2 IQ_CAT_T_B1S2_V2

  • Request21 3E
  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2015.

Check mode on IQ_CHECK_MODE_ON

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Closed throttle position switch on IQ_CLOSED_THROTTLE_POS_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Codes, include history IQ_CODES_INCLUDE

  • Request21 E1
  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Continuously variable transmission learning complete IQ_CVT_LEARNED

  • Request21 DD
  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2012 to 2015.

Continuously variable transmission oil pressure IQ_CVT_OIL_P

  • Request21 BE
  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 40)
Range
0 to 10200 kPa
Unit
kPa

In testing for 2012 to 2015.

Coolant temperature IQ_COOLANT_TEMP_7E0

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Coolant water route switching valve 1, closed? IQ_COOLANT_VALVE_1_CLOSE

  • Request22 28 2C
  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2015.

Coolant water route switching valve 2, closed? IQ_COOLANT_VALVE_2_CLOSE

  • Request22 28 47
  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2015.

Cooling fan duty ratio IQ_COOLING_FAN_DUTY_RATIO

  • Request22 10 46
  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 127.5 ÷ 255)
Range
0 to 127.5 %
Unit
%

In testing for 2012 to 2015.

Cruise control on IQ_CRUISE_CTRL_ON

  • Request21 D3
  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Cylinder 1 injection volume IQ_CYL_1_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015.

Cylinder 2 injection volume IQ_CYL_2_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015.

Cylinder 3 injection volume IQ_CYL_3_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015.

Cylinder 4 injection volume IQ_CYL_4_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015.

Cylinder number IQ_CYLINDER_NUMBER

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Destination IQ_DESTINATION

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Dist battery cable disconnect IQ_DIST_BATT_CABLE

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2012 to 2015.

Electric fan motor on IQ_ELEC_FAN_MOTOR_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Electric thermostat duty ratio IQ_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Request22 28 29
  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2012 to 2015.

Electric water pump IQ_ELECTRIC_WATER_PUMP

  • Request22 28 27
  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 40)
Range
0 to 10200 rpm
Unit
rpm

In testing for 2012 to 2015.

Electric water pump RPM IQ_EWP_RPM

  • Request22 10 43
  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2012 to 2015.

Electric water pump target speed IQ_EWP_TARGET_VSS

  • Request22 10 43
  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2012 to 2015.

Engine coolant temperature IQ_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Request21 26
  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 + 1.3)
Range
1.3 to 90.55 °C
Unit
°C

In testing for 2012 to 2015.

Engine coolant temperature IQ_ECT_7C0

Pelican can show this parameter as the engine coolant temperature.

  • Request21 23
  • Service 21PID 23
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 °C
Unit
°C

In testing for 2012 to 2015.

Engine coolant temperature, at ignition IQ_ECT_IGN

  • Request22 10 41
  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 62.5 ÷ 100 − 40)
Range
-40 to 119.375 °C
Unit
°C

In testing for 2012 to 2015.

Engine coolant temperature, initial IQ_ECT_INIT

  • Request22 10 41
  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 62.5 ÷ 100 − 40)
Range
-40 to 119.375 °C
Unit
°C

In testing for 2012 to 2015.

Engine independent IQ_ENG_INDEPENDENT

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Engine independent control IQ_ENG_INDEPENDENT_CTRL

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Engine oil pressure IQ_EOP

  • Request22 10 74
  • Service 22DID 1074
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10 ÷ 128)
Range
0 to 5119.92 kPa
Unit
kPa

In testing for 2012 to 2015.

Engine oil pressure control valve IQ_EOP_CONTROL_VALVE

  • Request22 28 48
  • Service 22DID 2848
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0762939)
Range
0 to 4999.9207 mA
Unit
mA

In testing for 2012 to 2015.

Engine oil temperature IQ_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Engine oil temperature IQ_EOT_700

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 7B
  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Engine oil temperature, variation 2 IQ_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 1F 5C
  • Service 22DID 1F5C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Engine run time IQ_ENGINE_RUN_TIME

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2012 to 2015.

Engine run time, up to 255 sec. only IQ_ENG_RUN_TIME_UP_255

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2012 to 2015.

Engine speed IQ_ENGINE_SPEED_7E0

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2012 to 2015.

Engine stall control FB flow IQ_ENG_STALL_CTRL_FB

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096 − 40)
Range
-40 to 39.99
Unit
Number

In testing for 2012 to 2015.

Evaporative purge duty IQ_EVAP_PURGE_DUTY_7E0

  • Request21 2E
  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2015.

Evaporative purge flow IQ_EVAP_PURGE_FLOW

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.99 %
Unit
%

In testing for 2012 to 2015.

Evaporative purge vacuum switching valve on IQ_EVAP_PURGE_VSV_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Exhaust gas recirculation step position IQ_EGR_STEP_POSITION

  • Request21 47
  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Exhaust gas recirculation temperature IQ_EGR_T

  • Request21 ED
  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 53 ÷ 85)
Range
0 to 159 °C
Unit
°C

In testing for 2012 to 2015.

Exhaust gas recirculation valve step IQ_EGR_STEP

  • Request21 E7
  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Exhaust VVT change angle, bank 1 IQ_EXHAUST_VVT_ANGLE_B1

  • Request22 10 88
  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

In testing for 2012 to 2015.

Exhaust VVT hold learn value, bank 1 IQ_EXHAUST_VVT_HOLD_LEARN_B1

  • Request22 10 89
  • Service 22DID 1089
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 399.9 ÷ 65535)
Range
0 to 399.9 %
Unit
%

In testing for 2012 to 2015.

Exhaust VVT oil control valve control duty IQ_EXHAUST_VVT_OCV_CONTROL_DUTY

  • Request22 10 62
  • Service 22DID 1062
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 400 ÷ 65535)
Range
0 to 400 %
Unit
%

In testing for 2012 to 2015.

Exhaust VVT target angle B1 IQ_EXHAUST_VVT_TARGET_ANGLE_B1

  • Request22 10 71
  • Service 22DID 1071
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

In testing for 2012 to 2015.

Exhaust VVT timing most over-advanced learn value, bank 1 IQ_EXHAUST_VVT_OVER_ADV_LEARN_B1

  • Request22 10 8F
  • Service 22DID 108F
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

In testing for 2012 to 2015.

Fuel cut for engine stop request IQ_F_C_ENG_STOP_REQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Fuel cut TAU on IQ_FC_TAU_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Fuel filter temperature IQ_FFT

  • Request22 10 9A
  • Service 22DID 109A
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

G sensor calibration, complete IQ_G_SENS_CALIBRATION

  • Request21 83
  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

G sensor learning value IQ_G_SENS_LEARNING

  • Request21 83
  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2012 to 2015.

Glass humidity IQ_GLASS_HUMIDITY

  • Request21 B1
  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2015.

Glass temperature IQ_GLASS_T

  • Request21 AF
  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 500 − 557.8)
Range
-557 to 621 °F
Unit
°F

In testing for 2012 to 2015.

Hydraulic valve, communication open IQ_HV_COMM_OPEN

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2015.

Idle control IQ_IDLE_CTRL

  • Request21 E6
  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Idle spark advance control 1 IQ_IDLE_SPARK_ADVN_CTRL_1

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2012 to 2015.

Idle spark advance control 2 IQ_IDLE_SPARK_ADVN_CTRL_2

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2012 to 2015.

Idle spark advance control 3 IQ_IDLE_SPARK_ADVN_CTRL_3

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2012 to 2015.

Idle spark advance control 4 IQ_IDLE_SPARK_ADVN_CTRL_4

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2012 to 2015.

Idle spark advance control, cylinder 1 IQ_IDLE_SAC_CYL_1

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 2012 to 2015.

Idle spark advance control, cylinder 2 IQ_IDLE_SAC_CYL_2

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 2012 to 2015.

Idle spark advance control, cylinder 3 IQ_IDLE_SAC_CYL_3

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 2012 to 2015.

Idle spark advance control, cylinder 4 IQ_IDLE_SAC_CYL_4

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 2012 to 2015.

Idle speed control learning IQ_IDLE_SPD_CTRL

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Idle speed control learning value, l/s IQ_IDLE_SPD_CTRL_L_S

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val × 0.0012206912)
Range
0 to 79.99
Unit
Number

In testing for 2012 to 2015.

IG OFF elapsed time IQ_IG_OFF_ELAPSED_TIME

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 min
Unit
min

In testing for 2012 to 2015.

Ignition advance IQ_SPARKADV_21

  • Request21 0E
  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

In testing for 2012 to 2015.

Ignition timing advance IQ_IGN_ADVANCE

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

In testing for 2012 to 2015.

Immobilizer communication on IQ_IMMOBILIZER_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Initial engine coolant temperature IQ_INITIAL_ECT

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 531 ÷ 850 − 40)
Range
-40 to 119.3
Unit
Number

In testing for 2012 to 2015.

Initial intake air temperature IQ_INITIAL_IAT

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 2012 to 2015.

Injection IQ_INJECTION

  • Request22 10 19
  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

In testing for 2012 to 2015.

Injection duration for cylinder 1 IQ_INJ_DUR_CYL_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

In testing for 2012 to 2015.

Injection feedback value 1 IQ_INJ_FEEDBACK_1

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 1 IQ_INJ_FEEDBACK_1_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 2 IQ_INJ_FEEDBACK_2

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 2 IQ_INJ_FEEDBACK_2_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 3 IQ_INJ_FEEDBACK_3

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 3 IQ_INJ_FEEDBACK_3_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 4 IQ_INJ_FEEDBACK_4

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 4 IQ_INJ_FEEDBACK_4_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 5 IQ_INJ_FEEDBACK_5

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015.

Injection feedback value 6 IQ_INJ_FEEDBACK_6

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015.

Injection volume IQ_INJ_VOL

  • Request22 10 17
  • Service 22DID 1017
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 3200)
Range
0 to 20 L
Unit
L

In testing for 2012 to 2015.

Injection volume - target IQ_INJ_VOLUME_TGT

  • Request22 11 2C
  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000)
Range
0 to 15
Unit
Raw value

In testing for 2012 to 2015.

Injection volume 1 IQ_INJ_VOLUME_1

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015.

Injection volume 2 IQ_INJ_VOLUME_2

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015.

Injection volume 3 IQ_INJ_VOLUME_3

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015.

Injection volume 5 IQ_INJ_VOLUME_5

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015.

Injection volume 6 IQ_INJ_VOLUME_6

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015.

Injection volume per 10 injections, cylinder 1 IQ_INJ_VOL_CYL_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32000000)
Range
0 to 0.002 L
Unit
L

In testing for 2012 to 2015.

Injection volume total IQ_INJ_VOLUME_TOT

  • Request22 11 2F
  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015.

Injector port IQ_INJECTOR_PORT

  • Request22 10 18
  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

In testing for 2012 to 2015.

Injector pulse width IQ_INJ_PW

  • Request21 E4
  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 163 ÷ 1275)
Range
0 to 32.6 ms
Unit
ms

In testing for 2012 to 2015.

Injector pulse width IQ_INJ_WIDTH

  • Request21 F3
  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 16 ÷ 125)
Range
0 to 32.64 ms
Unit
ms

In testing for 2012 to 2015.

Input shaft speed IQ_SPD_NIN

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2012 to 2015.

Intake air temperature IQ_IAT_21

  • Request21 0F
  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Intake air temperature IQ_INTAKE_AIR_7E0

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Intake air temperature, bank 1 sensor 1 IQ_IAT_B1S1

  • Request22 1F 77
  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Intake air temperature, bank 1 sensor 2 IQ_IAT_B1S2

  • Request22 1F 77
  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Intake VVT change angle, bank 1 IQ_INTAKE_VVT_CHANGE_ANGLE_BANK_1

  • Request22 10 87
  • Service 22DID 1087
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

In testing for 2012 to 2015.

Intake VVT most over-retarded learn value, bank 1 IQ_INTAKE_VVT_OVER_RET_LEARN_B1

  • Request22 10 8D
  • Service 22DID 108D
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

In testing for 2012 to 2015.

Intake VVT target angle B1 IQ_INTAKE_VVT_TARGET_ANGLE_B1

  • Request22 10 6F
  • Service 22DID 106F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

In testing for 2012 to 2015.

Integrated engine run time IQ_INTEGRATED_ENG_RUN

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2012 to 2015.

Intercooler coolant temperature IQ_INTERCOOLER_ECT

  • Request22 11 9C
  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Intercooler water pump IQ_INTERCOOLER_WATER

  • Request22 28 20
  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 80 ÷ 13107)
Range
0 to 300 %
Unit
%

In testing for 2012 to 2015.

Internal temperature IQ_ECU_INTERNAL_T

  • Request22 10 5E
  • Service 22DID 105E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Judge time engine ignition IQ_JUDGE_TIME_ENG_IGN

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2012 to 2015.

Judge time engine output IQ_JUDGE_TIME_ENG

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2012 to 2015.

Knock adjust IQ_KNOCK_ADJUST

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 64)
Range
-64 to 1984 °
Unit
°

In testing for 2012 to 2015.

Knock adjust IQ_KNOCK_ADJUST_7E0

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 1024)
Range
-1024 to 1024 °
Unit
°

In testing for 2012 to 2015.

Knock correct learn value IQ_KNOCK_CORRECT_LEARN

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 32 − 1024)
Range
-1024 to 1023 °
Unit
°

In testing for 2012 to 2015.

Knock correction, learned value IQ_KNOCK_CORRECT_LEARNED_VALUE

  • Request22 10 5C
  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 312.5 ÷ 10000 − 1024)
Range
-1024 to 1023
Unit
Number

In testing for 2012 to 2015.

Knock feedback IQ_KNOCK_FEEDBACK

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 64)
Range
-64 to 1984 °
Unit
°

In testing for 2012 to 2015.

Knock feedback IQ_KNOCK_FEEDBACK_7E0

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 1024)
Range
-1024 to 1024 °
Unit
°

In testing for 2012 to 2015.

Knock feedback value IQ_KNOCK_FEEDBACK_VALUE

  • Request22 10 5C
  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 312.5 ÷ 10000 − 1024)
Range
-1024 to 1023
Unit
Number

In testing for 2012 to 2015.

Lock up state IQ_LOCK_UP_STATE

  • Request22 16 20
  • Service 22DID 1620
  • Module701 → 709
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Long term fuel trim, bank 1 IQ_LONG_FT_B1

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

In testing for 2012 to 2015.

Long term fuel trim, bank 2 IQ_LONG_FT_B2

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

In testing for 2012 to 2015.

Long-term fuel trim, bank 1 IQ_LTFT1_21

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.7809803922 − 100)
Range
-100 to 99.15 %
Unit
%

In testing for 2012 to 2015.

Manifold absolute pressure IQ_MAP_7E0

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2012 to 2015.

Mass air flow IQ_MAF_21

  • Request21 10
  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 g/s
Unit
g/s

In testing for 2012 to 2015.

Mass air flow IQ_MAF_7E0

Pelican can show this parameter as the mass air flow.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2012 to 2015.

Master cylinder open IQ_MASTER_CYLINDER_OPEN

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2015.

Master cylinder sensor temperature IQ_MASTER_CYL_TEMP

  • Request22 10 06
  • Service 22DID 1006
  • Module7B0 → 7B8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 80)
Range
-20 to 100 °C
Unit
°C

In testing for 2012 to 2015.

Misfire count, all cylinders IQ_MISFIRE_CNT

  • Request22 10 A5
  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Misfire count, cylinder 1 IQ_MISFIRE_CYL1

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Misfire count, cylinder 2 IQ_MISFIRE_CYL2

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Misfire count, cylinder 3 IQ_MISFIRE_CYL3

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Misfire count, cylinder 4 IQ_MISFIRE_CYL4

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Misfire load IQ_MISFIRE_LOAD

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 510 ÷ 255)
Range
0 to 510 %
Unit
%

In testing for 2012 to 2015.

Misfire margin IQ_MISFIRE_MARGIN

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 rpm
Unit
rpm

In testing for 2012 to 2015.

Misfire RPM IQ_MISFIRE_RPM

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 6375 ÷ 255)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2012 to 2015.

Misfire RPM IQ_MISFIRE_RPM_7E0

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2012 to 2015.

Misfire test result, incomplete IQ_MIS_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Model year IQ_MODEL_YEAR

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val + 1900)
Range
1900 to 2155
Unit
Number

In testing for 2012 to 2015.

O2 heater b1s2_active IQ_O2_HEATER_B1S2

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

O2 heater current val bank 1 sensor 2 IQ_O2_HEATER_CURR_VAL

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 A
Unit
A

In testing for 2012 to 2015.

Open side malfunction on IQ_OPEN_SIDE_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Output shaft speed IQ_SPD_NOUT

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2012 to 2015.

OXS1, A/FS2 test result, incomplete IQ_OXS1_FS2_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Oxygen sensor voltage, bank 1 sensor 1 IQ_O2S11_V

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.0049960784)
Range
0 to 1.27 V
Unit
V

In testing for 2012 to 2015.

Oxygen sensor voltage, bank 1 sensor 2 IQ_O2S_B1S2

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val × 5 ÷ 1000)
Range
0 to 1.275 V
Unit
V

In testing for 2012 to 2015.

PM accumulation ratio - bank 1 IQ_PM_ACCUMULATION_RAT_1

  • Request22 11 05
  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 15 %
Unit
%

In testing for 2012 to 2015.

Purge cut vacuum switching valve duty IQ_PURGE_CUT_VSV_DUTY

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2012 to 2015.

Racing operation IQ_RACING_OPERATION

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Real engine torque IQ_REAL_ENG_TQ

  • Request22 10 09
  • Service 22DID 1009
  • Module7B1 → 7B9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-20 to 150 N·m
Unit
N·m

In testing for 2012 to 2015.

Regulator pressure IQ_REGULATOR_P

  • Request21 53
  • Service 21PID 53
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 375105 ÷ 25500 − 456.68)
Range
-456.68 to 3294 kPa
Unit
kPa

In testing for 2012 to 2015.

Request engine run time IQ_REQ_ENG_RUN_TIME

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2012 to 2015.

Request warm-up IQ_REQ_WARM_UP

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Requested engine torque IQ_REQ_ENG_TQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383
Unit
Number

In testing for 2012 to 2015.

Rough idle, cylinder 1 IQ_ROUGH_IDLE_CYL_1

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2012 to 2015.

Rough idle, cylinder 2 IQ_ROUGH_IDLE_CYL_2

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2012 to 2015.

Rough idle, cylinder 3 IQ_ROUGH_IDLE_CYL_3

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2012 to 2015.

Rough idle, cylinder 4 IQ_ROUGH_IDLE_CYL_4

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2012 to 2015.

Short term fuel trim, bank 1 IQ_SHORT_FT_B1

Pelican can show this parameter as the short term fuel trim.

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

In testing for 2012 to 2015.

Short term fuel trim, bank 2 IQ_SHORT_FT_B2

Pelican can show this parameter as the short term fuel trim.

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

In testing for 2012 to 2015.

Starter relay on IQ_STARTER_RELAY_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Steering angle IQ_STEER_ANG

  • Request22 10 09
  • Service 22DID 1009
  • Module7B1 → 7B9
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10 − 3276.8)
Range
-20 to 150 °
Unit
°

In testing for 2012 to 2015.

Stroke open IQ_STROKE_OPEN

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2015.

Synchronize stroke sensor position IQ_SYNCHRONIZE_STROKE

  • Request22 16 34
  • Service 22DID 1634
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 256 ÷ 65535)
Range
0 to 256 mm
Unit
mm

In testing for 2012 to 2015.

System guard on IQ_SYSTEM_GUARD_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Throttle fully close learn IQ_THROTTLE_FULLY_CLOSE

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2012 to 2015.

Throttle idle position on IQ_THROTTLE_IDLE_POS_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Throttle motor current IQ_THROTTLE_MOTOR

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 19.9 A
Unit
A

In testing for 2012 to 2015.

Throttle motor duty IQ_THROTTLE_MOTOR_DUTY

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2015.

Throttle motor duty, close IQ_THROTTLE_MOTOR_DUTY_CLOSE

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2012 to 2015.

Throttle motor duty, open IQ_THROTTLE_MOTOR_DUTY_OPEN

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2012 to 2015.

Throttle position IQ_THROTTLE_21

  • Request21 11
  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2015.

Throttle position command IQ_THROTTLE_POS_COMMAND

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2012 to 2015.

Throttle position, number 1 IQ_THROTTLE_POS_NUMBER_1

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2012 to 2015.

Throttle position, number 2 IQ_THROTTLE_POS_NUMBER_2

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2012 to 2015.

Throttle require position IQ_THROTTLE_REQUIRE_POS

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2012 to 2015.

Throttle sensor open position 1 IQ_THROTTLE_SENS_OPEN_1

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2012 to 2015.

Throttle sensor open position 2 IQ_THROTTLE_SENS_OPEN_2

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2012 to 2015.

Throttle sensor position IQ_THROTTLE_SENSOR_POSITION

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2015.

Throttle sensor voltage, 1 IQ_THROTTLE_SENSOR_VOLT

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2015.

Throttle sensor voltage, 2 IQ_THROTTLE_SENSOR_2_VOLT

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2015.

Time since DTCs cleared IQ_TIME_SINCE_DTC_CLEARED

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2012 to 2015.

Total fuel trim, bank 1 IQ_TOT_FT_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 256 − 50)
Range
-50 to 49.6 %
Unit
%

In testing for 2012 to 2015.

Transmission fluid pan temperature IQ_TF1_PAN

  • Request22 16 27
  • Service 22DID 1627
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.00703125 − 40)
Range
-40 to 350 °F
Unit
°F

In testing for 2012 to 2015.

Transmission fluid temperature IQ_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 38
  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Transmission fluid temperature, after the torque converter IQ_TF2_CONV

  • Request22 16 28
  • Service 22DID 1628
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.00703125 − 40)
Range
-40 to 350 °F
Unit
°F

In testing for 2012 to 2015.

Transmission output shaft speed IQ_TRANS_OUT_RPM

  • Request21 BD
  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2012 to 2015.

Turbine speed IQ_SPD_NT

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2012 to 2015.

Valvematic current angle IQ_VALVEMATIC_CURRENT

  • Request21 31
  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 512)
Range
0 to 639.9 °
Unit
°

In testing for 2012 to 2015.

Valvematic, target angle IQ_VALVEMATIC_TGT_ANG

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 512)
Range
0 to 639.9 °
Unit
°

In testing for 2012 to 2015.

Variable valve timing aim angle 1 IQ_VARIABLE_VLV_TIM_AIM_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1333 ÷ 218450)
Range
0 to 399 %
Unit
%

In testing for 2012 to 2015.

Variable valve timing change angle 1 IQ_VARIABLE_VLV_TIM_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 0.0097642481)
Range
0 to 639 °
Unit
°

In testing for 2012 to 2015.

Variable valve timing control status 1 on IQ_VARIABLE_VLV_TIM_1_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Variable valve timing oil control valve duty 1 IQ_VARIABLE_VLV_TIM_OIL_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0061020829)
Range
0 to 399 %
Unit
%

In testing for 2012 to 2015.

Variable valve timing oil temperature IQ_VVTOT

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015.

Variable valve timing opening angle bank 1 IQ_VVT_IE_OPENING_ANGLE_BANK_1

  • Request22 28 43
  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2012 to 2015.

Vehicle speed IQ_VSS_21

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2012 to 2015.

Vehicle speed sensor test result, incomplete IQ_SPD_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2012 to 2015.

Warm-up cycles since DTCs cleared IQ_WARMUP_CYCLES_DTC_CLEARED

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Engine › Catalyst

Catalyst temperature, bank 1 sensor 1 IQ_CAT_T_11

  • Request22 1F 3C
  • Service 22DID 1F3C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2015.

Catalyst temperature, bank 1 sensor 2 IQ_CAT_T_12

  • Request22 1F 3E
  • Service 22DID 1F3E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2015.

Engine › Misfires

All cylinders misfire count IQ_ALL_CYLINDERS_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Cylinder #1 misfire count IQ_CYL1_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Cylinder #2 misfire count IQ_CYL2_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Cylinder #3 misfire count IQ_CYL3_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Cylinder #4 misfire count IQ_CYL4_MISFIRE_CNT

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2015.

Misfire load IQ_MISFIRE_LOAD_7E0

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 4 ÷ 256)
Range
0 to 3.98
Unit
Number

In testing for 2012 to 2015.

Misfire margin IQ_MISFIRE_MARGIN_7E0

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 %
Unit
%

In testing for 2012 to 2015.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.