Scion iQ

Battery parameters

The Scion iQ has 33 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

+BM voltage IQ_BM_V

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2012 to 2015.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

+BM voltage IQ_BM_V

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2012 to 2015.

1st turbocharger outlet pressure, control valve IQ_1ST_TRUBOCHARGER_P

  • Request22 11 CD
  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015.

2nd turbocharger outlet pressure IQ_2ND_TRUBOCHARGER_OUTLET_P

  • Request22 11 AF
  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015.

2nd turbocharger outlet pressure, control valve IQ_2ND_TRUBOCHARGER_P

  • Request22 11 CD
  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015.

Aux. battery capacity after IG OFF IQ_AUX_BAT_CAP_AFTER_IG_OFF

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 Ah
Unit
Ah

In testing for 2012 to 2015.

Aux. battery capacity after IG ON IQ_AUX_BAT_CAP_AFTER_IG_ON

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 Ah
Unit
Ah

In testing for 2012 to 2015.

Battery current IQ_BAT_CURRENT

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 50 ÷ 13107 − 125)
Range
-125 to 124.9 A
Unit
A

In testing for 2012 to 2015.

Battery current IQ_BAT_CURRENT_700

  • Request22 15 F7
  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 49 ÷ 12850 − 125)
Range
-125 to 124.9 A
Unit
A

In testing for 2012 to 2015.

Battery status of full charge IQ_BAT_STAT_FULL_CHG

  • Request22 15 E5
  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 255 ÷ 2)
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 2012 to 2015.

Battery temperature IQ_BAT_T

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2012 to 2015.

Battery temperature IQ_BAT_T_700

  • Request22 15 F8
  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2015.

Battery temperature IQ_BAT_T_700_2

  • Request22 1F F8
  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2012 to 2015.

Battery voltage IQ_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 02
  • Service 22DID 1002
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12.207 ÷ 10000)
Range
0 to 79 V
Unit
V

In testing for 2012 to 2015.

Battery voltage IQ_BAT_V

  • Request21 13
  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2012 to 2015.

Battery voltage IQ_BATTERY_VOLTAGE_7E0

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2012 to 2015.

Charge contactor current IQ_SCC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2012 to 2015.

Charging integrated current of aux. battery IQ_CHG_INTEGRATED

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2012 to 2015.

Dark current of battery IQ_DARK_CURRENT_BAT

  • Request22 15 E7
  • Service 22DID 15E7
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2012 to 2015.

Discharging integrated current of aux. battery IQ_DISCHARGING

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2012 to 2015.

Distance since last battery cable disconnection IQ_DIST_SINCE_BAT_DISC

  • Request22 10 6C
  • Service 22DID 106C
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2012 to 2015.

Initial engine battery voltage lower limit IQ_INITIAL_ENG_BAT_V_LO

  • Request22 15 F6
  • Service 22DID 15F6
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2012 to 2015.

Main connector solenoid current IQ_SMC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2012 to 2015.

Main relay a, solenoid current IQ_SLA_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2012 to 2015.

Main relay r solenoid current IQ_SLR_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2012 to 2015.

Output speed sensor voltage IQ_NOUT_SENS_V

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 V
Unit
V

In testing for 2012 to 2015.

Regenerative braking cooperation IQ_REGEN_COOPERATION

  • Request21 58
  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2015.

Regenerative operation IQ_FR_REGEN_OPERATION

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2012 to 2015.

Regenerative request IQ_FR_REGEN_REQUEST

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2012 to 2015.

Relay control solenoid current IQ_SRC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2012 to 2015.

Service contactor solenoid current IQ_SSC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2012 to 2015.

Sleep time of battery sensor IQ_SLEEP_TIME_BATSENS

  • Request22 15 F0
  • Service 22DID 15F0
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 2012 to 2015.

Turbine speed sensor voltage IQ_NT_SENS_V

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 V
Unit
V

In testing for 2012 to 2015.

Voltage of battery sensor IQ_V_BATSENS

  • Request22 15 EE
  • Service 22DID 15EE
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13333 ÷ 10922500)
Range
0 to 79.9979 V
Unit
V

In testing for 2012 to 2015.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.