Scion FR-S

ECU parameters

The Scion FR-S has 28 ECU parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/F sensor #1 FRS_A_F_SENSOR_1

  • Request22 10 BE
  • Service 22DID 10BE
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1.99 ÷ 255)
Range
0 to 1.99
Unit
Number

In testing for 2013 to 2016.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/F sensor #1 FRS_A_F_SENSOR_1

  • Request22 10 BE
  • Service 22DID 10BE
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1.99 ÷ 255)
Range
0 to 1.99
Unit
Number

In testing for 2013 to 2016.

Alternator duty FRS_ALTERNATOR_DUTY

  • Request22 10 B2
  • Service 22DID 10B2
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2016.

Canister purge control valve duty cycle FRS_CPC_VALVE_DUTY_CYCLE

  • Request22 10 AE
  • Service 22DID 10AE
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2016.

Cylinder monitor #1 FRS_MONITOR_1

  • Request22 13 14
  • Service 22DID 1314
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2016.

Cylinder monitor #2 FRS_MONITOR_2

  • Request22 13 15
  • Service 22DID 1315
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2016.

Cylinder monitor #3 FRS_MONITOR_3

  • Request22 13 16
  • Service 22DID 1316
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2016.

Cylinder monitor #4 FRS_MONITOR_4

  • Request22 13 17
  • Service 22DID 1317
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2016.

Engine starting time FRS_ENGINE_STARTING_TIME

  • Request22 12 9C
  • Service 22DID 129C
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 ms
Unit
ms

In testing for 2013 to 2016.

Exhaust gas recirculation steps FRS_EGR_STEPS

  • Request22 10 B1
  • Service 22DID 10B1
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2016.

Exhaust gas recirculation valve opening angle FRS_EGR_VALVE_OPENING_ANGLE

  • Request22 11 1C
  • Service 22DID 111C
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 2013 to 2016.

Exhaust OCV duty left FRS_EXHAUST_OCV_DUTY_LEFT

  • Request22 10 EF
  • Service 22DID 10EF
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2016.

Exhaust OCV duty right FRS_EXHAUST_OCV_DUTY_RIGHT

  • Request22 10 EE
  • Service 22DID 10EE
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2016.

Intake VVT advance angle left FRS_INTAKE_VVT_ADVANCE_LEFT

  • Request22 10 B5
  • Service 22DID 10B5
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 2013 to 2016.

Intake VVT advance angle right FRS_INTAKE_VVT_ADVANCE_RIGHT

  • Request22 10 B4
  • Service 22DID 10B4
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 2013 to 2016.

Interior heater FRS_INTERIOR_HEATER

  • Request22 11 2C
  • Service 22DID 112C
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2016.

Lock up duty ratio FRS_LOCK_UP_DUTY_RATIO

  • Request22 10 C8
  • Service 22DID 10C8
  • Module7A3 → 7AB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 2013 to 2016.

Oil control valve duty left FRS_OCV_DUTY_LEFT

  • Request22 10 B7
  • Service 22DID 10B7
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2016.

Oil control valve duty right FRS_OCV_DUTY_RIGHT

  • Request22 10 B6
  • Service 22DID 10B6
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2016.

Oil level switch FRS_OIL_LEVEL_SWITCH

  • Request22 12 4C
  • Service 22DID 124C
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2016.

Oil supply value, duty left FRS_OSV_DUTY_LEFT

  • Request22 10 E9
  • Service 22DID 10E9
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2016.

Oil supply value, duty right FRS_OSV_DUTY_RIGHT

  • Request22 10 E8
  • Service 22DID 10E8
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2016.

Radiator fan control FRS_RADIATOR_FAN

  • Request22 10 AB
  • Service 22DID 10AB
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 %
Unit
%

In testing for 2013 to 2016.

Roughness monitor #1 FRS_ROUGHNESS_MONITOR_1

  • Request22 11 0B
  • Service 22DID 110B
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2016.

Roughness monitor #2 FRS_ROUGHNESS_MONITOR_2

  • Request22 11 0C
  • Service 22DID 110C
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2016.

Roughness monitor #3 FRS_ROUGHNESS_MONITOR_3

  • Request22 11 0D
  • Service 22DID 110D
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2016.

Roughness monitor #4 FRS_ROUGHNESS_MONITOR_4

  • Request22 11 0E
  • Service 22DID 110E
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2016.

Target intake manifold pressure FRS_TARGET_INTAKE_MANIFOLD_PRESSURE

  • Request22 11 18
  • Service 22DID 1118
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 50 kPa
Unit
kPa

In testing for 2013 to 2016.

Throttle motor duty FRS_THROTTLE_MOTOR_DUTY

  • Request22 10 DE
  • Service 22DID 10DE
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.784 − 100)
Range
-100 to 99.92 %
Unit
%

In testing for 2013 to 2016.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.