Scion FR-S

Battery parameters

The Scion FR-S has 8 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery current FRS_12V_C

  • Request22 11 35
  • Service 22DID 1135
  • Module7A2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 mA
Unit
mA

In testing for 2013 to 2016.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery current FRS_12V_C

  • Request22 11 35
  • Service 22DID 1135
  • Module7A2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 mA
Unit
mA

In testing for 2013 to 2016.

12V battery temperature FRS_12V_T

  • Request22 11 36
  • Service 22DID 1136
  • Module7A2
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2016.

Battery charge/discharge current FRS_BAT_CHARGE_DISCHARGE_CURRENT

  • Request22 13 22
  • Service 22DID 1322
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 10 ÷ 10000 − 2000)
Range
-2000 to 4292967 A
Unit
A

In testing for 2013 to 2016.

Battery terminal voltage FRS_BAT_TERMINAL_VOLTAGE

Pelican can show this parameter as the starter battery voltage.

  • Request22 13 21
  • Service 22DID 1321
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2013 to 2016.

Estimated battery temperature FRS_ESTIMATED_BAT_T

  • Request22 13 23
  • Service 22DID 1323
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 32727.5 °C
Unit
°C

In testing for 2013 to 2016.

Mass airflow sensor voltage FRS_MAF_VOLTAGE

  • Request22 10 A1
  • Service 22DID 10A1
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 2013 to 2016.

Remaining battery capacity FRS_REMAINING_BAT_CAPACITY

Pelican can show this parameter as the state of charge.

  • Request22 13 24
  • Service 22DID 1324
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

In testing for 2013 to 2016.

Throttle motor voltage FRS_THROTTLE_MOTOR_V

  • Request22 12 75
  • Service 22DID 1275
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 ÷ 25)
Range
0 to 20.4 V
Unit
V

In testing for 2013 to 2016.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.