Inverter high voltage ZOE_INV_HV_V

  • Request22 20 04
  • Service 22DID 2004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.9687 V
Unit
V

In testing for 2012 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Inverter high voltage ZOE_INV_HV_V

  • Request22 20 04
  • Service 22DID 2004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.9687 V
Unit
V

In testing for 2012 to 2024.

Inverter high voltage current ZOE_INV_HV_A

  • Request22 70 49
  • Service 22DID 7049
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32 − 500)
Range
-500 to 1547.9687 A
Unit
A

In testing for 2012 to 2024.

Inverter state ZOE_INV_STATE

  • Request22 21 CF
  • Service 22DID 21CF
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
1OFFOff
2ONOn
3DISCHARGINGDischarging
4ALTERNATORAlternator mode
5SLEEP_READYReady to sleep

In testing for 2012 to 2024.

Inverter temperature ZOE_INV_T

  • Request22 70 0C
  • Service 22DID 700C
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 512 − 40)
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2012 to 2024.

Inverter temperature, power electronics ZOE_INV_T_PEB

  • Request22 33 F6
  • Service 22DID 33F6
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2024.

Motor speed ZOE_MOTOR_RPM

  • Request22 30 64
  • Service 22DID 3064
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2012 to 2024.

Rotor current sensor 1 ZOE_ROTOR_A1

  • Request22 70 03
  • Service 22DID 7003
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 A
Unit
A

In testing for 2012 to 2024.

Rotor current sensor 2 ZOE_ROTOR_A2

  • Request22 70 04
  • Service 22DID 7004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 A
Unit
A

In testing for 2012 to 2024.

Rotor reference resistance ZOE_ROTOR_R

  • Request22 70 50
  • Service 22DID 7050
  • ModuleDADF → DF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.998 Ω
Unit
Ω

In testing for 2012 to 2024.

Rotor temperature, estimated ZOE_ROTOR_T

  • Request22 70 88
  • Service 22DID 7088
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 − 40)
Range
-40 to 471.9921 °C
Unit
°C

In testing for 2012 to 2024.

Rotor temperature, raw ZOE_ROTOR_T_RAW

  • Request22 70 38
  • Service 22DID 7038
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 − 40)
Range
-40 to 471.9921 °C
Unit
°C

In testing for 2012 to 2024.

Stator current, phase U ZOE_STATOR_A_U

  • Request22 70 07
  • Service 22DID 7007
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32 − 500)
Range
-500 to 1547.9687 A
Unit
A

In testing for 2012 to 2024.

Stator current, phase V ZOE_STATOR_A_V

  • Request22 70 08
  • Service 22DID 7008
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32 − 500)
Range
-500 to 1547.9687 A
Unit
A

In testing for 2012 to 2024.

Stator current, phase W ZOE_STATOR_A_W

  • Request22 70 09
  • Service 22DID 7009
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32 − 500)
Range
-500 to 1547.9687 A
Unit
A

In testing for 2012 to 2024.

Stator temperature 1 ZOE_STATOR_T1

  • Request22 70 0F
  • Service 22DID 700F
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 512 − 40)
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2012 to 2024.

Stator temperature 2 ZOE_STATOR_T2

  • Request22 70 10
  • Service 22DID 7010
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 512 − 40)
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2012 to 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.