The Polestar 3 has 25 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/T converter POLESTAR_T_CONV

  • Request22 1E 14
  • Service 22DID 1E14
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/T converter POLESTAR_T_CONV

  • Request22 1E 14
  • Service 22DID 1E14
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

AT, actual gear ratio POLESTAR_ACT_GEAR_RAT

  • Request22 1E 16
  • Service 22DID 1E16
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.99
Unit
Number

In testing for 2024 to 2026.

Clutch 1 temperature POLESTAR_CLU_1_T

  • Request22 D9 26
  • Service 22DID D926
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Clutch 2 temperature POLESTAR_CLU_2_T

  • Request22 D9 40
  • Service 22DID D940
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Clutch actuator 1 temperature POLESTAR_CLU_ACTUATOR_1_T

  • Request22 D9 6B
  • Service 22DID D96B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Clutch actuator 2 temperature POLESTAR_CLU_ACTUATOR_2_T

  • Request22 D9 74
  • Service 22DID D974
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Clutch pump duty POLESTAR_CLU_PMP_DUTY

  • Request22 D9 20
  • Service 22DID D920
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Gear POLESTAR_GEAR

  • Request22 DA 85
  • Service 22DID DA85
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Gear ratio expected POLESTAR_GEAR_RAT_EXPECTED

  • Request22 DA 47
  • Service 22DID DA47
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2024 to 2026.

Gear ratio, actual POLESTAR_GEAR_RAT_ACT

  • Request22 DA 34
  • Service 22DID DA34
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 61 ÷ 250000)
Range
0 to 15.99
Unit
Number

In testing for 2024 to 2026.

Gear ratio, actual POLESTAR_GEAR_RAT_ACT_7E1

  • Request22 DA 34
  • Service 22DID DA34
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.99
Unit
Number

In testing for 2024 to 2026.

Gear ratio, requested POLESTAR_GEAR_RAT_REQ

  • Request22 DA 47
  • Service 22DID DA47
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2024 to 2026.

Gear, AT position POLESTAR_GEAR_POS

  • Request22 DA 40
  • Service 22DID DA40
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2024 to 2026.

Torque converter lock POLESTAR_TQ_CONV_LOCK

  • Request22 DA 3C
  • Service 22DID DA3C
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Transmission expected gear ratio POLESTAR_EXPECTED_GEAR_RAT

  • Request22 1E 19
  • Service 22DID 1E19
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53
Unit
Number

In testing for 2024 to 2026.

Transmission fluid temperature POLESTAR_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 DA 3B
  • Service 22DID DA3B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Transmission fluid temperature POLESTAR_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 1E 3F
  • Service 22DID 1E3F
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4)
Range
-8192 to 8191 °C
Unit
°C

In testing for 2024 to 2026.

Transmission fluid temperature POLESTAR_ATF_T_D016

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D9 0D
  • Service 22DID D90D
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 °C
Unit
°C

In testing for 2024 to 2026.

Transmission fluid temperature POLESTAR_ATF_T_D016_2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D9 00
  • Service 22DID D900
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1000)
Range
-32768000 to 32767000 °C
Unit
°C

In testing for 2024 to 2026.

Transmission fluid temperature POLESTAR_ATF_T_DA18

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 E0 04
  • Service 22DID E004
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Transmission fluid temperature, variant 2 POLESTAR_ATF_T_VAR_2

  • Request22 D9 04
  • Service 22DID D904
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Transmission fluid temperature, variant 2 POLESTAR_ATF_T_VAR_2_7E1

  • Request22 DA 3B
  • Service 22DID DA3B
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Transmission fluid temperature, variant 3 POLESTAR_ATF_T_VAR_3

  • Request22 D9 A1
  • Service 22DID D9A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 60)
Range
-60 to 195 °C
Unit
°C

In testing for 2024 to 2026.

Transmission gear POLESTAR_GEAR_7E1

  • Request22 DD 81
  • Service 22DID DD81
  • Module7E1
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Transmission gear selector p, 0 r, 1 n, 2 d, 3 POLESTAR_GEAR_SELECTOR_P_0_R_1_N_2_D_3

  • Request22 63 10
  • Service 22DID 6310
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?